ProSoft EIP-61850 Configuration Manager 2.0.2.10 Read Me

ProSoft EIP-61850 Configuration Manager 2.0.2.10
ReadMe File

This ReadMe file contains information you should know before you install ProSoft EIP-61850 Configuration Manager version 2.0.2.10 This file also contains information that may not be available in other ProSoft Technology documentation. Visit our website for the most current information about ProSoft EIP-61850 Configuration Manager.

Version 2.0.2.10 Changes:

  1. Updated user interface to include PLX82 1-Port and PLX82 2-Port functionality since the PLX81 is being discontinued.Configuration MManager continues to be backwards compatible with the obsolete PLX81-EIP-61850 product.
  2. Fixed an issue where IED names in their CID files included first 5 identical characters to other CID files that could not be accuratly differentiated.
  3. Fixed an issue where Control type for the MMS Write commands would apply as CtlTtype=0 when it should be CtlType=1.
  4. Fixed the property dialog box by replacing the selection “PLX81 - 1 port” to show as “PLX81” since PLX81 is a 1 port gateway.

ProSoft EIP-61850 Configuration Manager Compatibility

The following system requirements apply to ProSoft EIP-61850 Configuration Manager.

ProSoft EIP-61850 Configuration Manager installation instructions are provided in the ProLinx PLX82-EIP-61850 user manual.

Note: System requirements in this document are subject to change and do not represent a commitment to support any particular software or hardware.

ProSoft EIP-61850 Configuration Manager Operating Systems Tested

Previously Released versions of ProSoft EIP-61850 Configuration Manager

ProSoft EIP-61850 Configuration Manager 2.0.1.5

Detailed Reason(s) for Version 2.0.1.5 Changes:

  1. Fixes issue where the project name was not prefill as expected when using the Save As option
  2. Fixes issue where the AOI cannot be exported without first changing the module selection to a PLX82

ProSoft EIP-61850 Configuration Manager 2.0.0.22

Detailed Reason(s) for Version 2.0.0.22 Changes:

  1. Change Help/About tool name to ProSoft EIP-61850 Configuration Manager
  2. Report Control "RptEnabled Max" parameter set as 1 now adds 01 suffix to Report Name
  3. Resolves issue with GOOSE.IndXX where XX>9
  4. Resolves Control Type issue with PLX82
  5. Limits the database tag character limit to 50
  6. Updates to the .SCL parser with regards to reports
  7. Improved performance of the SCL parser to implement RptEnabled with a null "max" value
  8. Improved performance of the SCL parser to correct control datapath bug
  9. Changes to the Tag Name to fix an AOI import issue

ProSoft EIP-61850 Configuration Manager 1.2.1.5

Detailed Reason(s) for Version 1.2.1.5 Changes:

Added support for Array Type tags for controller.

ProSoft EIP-61850 Configuration Manager 1.2.0.2

Detailed Reason(s) for Version 1.2.0.2 Changes:

  1. Supports "rptEnabled" flag as used in Schneider CID files
  2. Support for both structured and unstructured GOOSE declarations
  3. Adjusts the MMSPath displayed in the app to be 61850 Spec compliant - ie: Adds domain name and Logical Device
  4. Upper limit on GOOSE attributes has been bumped from 60 to 120
  5. Fixes issue with the importing of Siemens CID files, changes to the PrjFiles
  6. Fixed an issue with the mapping layout when using Auto-Assign tags and issue with "undo" button
  7. Overall improvement of tag functionality and support of reports greater than 500 bytes

ProSoft EIP-61850 Configuration Manager 1.0.9.12

Detailed Reason(s) for Version 1.0.9.12 Changes:

Added support for PLX82-EIP-61850, allows user to edit the IED IP configuration.

ProSoft EIP-61850 Configuration Manager 1.0.7.1

Detailed Reason(s) for Version 1.0.7.1 Changes:

Fixes uploading issue where the configuration file was uploaded using a new computer.

ProSoft EIP-61850 Configuration Manager 1.0.6.1

Detailed Reason(s) for Version 1.0.6.1 Changes:

Fixes issues related to the exporting of gi parameter,and the tag name truncating.

ProSoft EIP-61850 Configuration Manager 1.0.4.7

Detailed Reason(s) for Version 1.0.4.7 Changes:

Supports SBO and enhanced security control; fixes compatibility issues with Areva CID files, numeric suffix were removed from default tag name.

ProSoft EIP-61850 Configuration Manager 1.0.0.96

Detailed Reason(s) for Version 1.0.0.96 Changes:

Initial Release.