HART Multi-Drop Communications ModuleMVI71-HARTThe MVI71 HART Multidrop Master Communication Module is a PLC backplane-compatible module that allows PLC processors to interface easily with HART compatible devices. Devices commonly supporting the protocol include pressure, temperature, flow transmitters, as well as other similar instruments commonly found in the process (and other) industry. HART® is a registered trademark of the HART Communication Foundation Features and BenefitsThe MVI71-HART Master Communication Module allows Rockwell Automation PLC I/O compatible processors to easily communicate with HART slave devices. The MVI71-HART module interfaces up to 15 devices on each HART channel with the Rockwell Automation PLC processor. Four channels on the module support master protocol commands to interface with slave devices on their own networks. Each port is individually configurable. Data is exchanged between the HART network and the Rockwell Automation PLC processor backplane using the internal database contained in the module and direct control by the controller's ladder logic and pre-defined data objects (5000 registers maximum). The MVI71-HART module is the perfect solution for industrial applications in chemical and refining operations, to gas and liquid distribution systems, and remote offshore monitoring stations are addressing virtually all aspects of control, data acquisition, and maintenance. General Specifications
The HART protocol is supported by major instrument suppliers and the HART Communication Foundation (HCF). Today, HART is the most widely used digital communications protocol for instruments in the process control industry. More than 105 manufacturers support HART with a choice of more than 170 different field instruments. Functional SpecificationsThe MVI71-HART module supports the HART Multidrop implementation of the protocol. Following are some general specifications for the module:
Protocol Supported: HART protocol uses the Bell 202 standard frequency shift-keying (FSK) digital signal to communicate at 1200 baud, superimposed at a low level on the 4 to 20mA analog measurement signal. Supported Function Codes: HART Universal Commands Set supported are 00-03, 06-09, and 11-22. HART Common Practice Commands Set supported are 33-83 and 105-110. HART Network Communications: Supports four master channels. Each channel on the module is configured independently to emulate a HART master. Burst mode can be used for faster update of data from a slave device. Command polling is also user-configurable, including disabled, continuous, on change of data (write only), and dynamically user or automatic enabled. Status: Error codes returned by the HART protocol available on an individual command basis. In addition, a slave status list is maintained per active channel. Ordering Information
Distributors: Sales and Support:
|
Related Articles |
||||||||||
ProSoft Technology, Inc. Copyright © 2003 - 2008