Modbus Master/Slave to PROFIBUS Master Communication Module
5104-MCM-PDPM
Product Description
The ProLinx family Modbus Master/Slave to PROFIBUS Master communications module (5104-MCM-PDPM) creates a powerful connection between devices on a Modbus network and PROFIBUS DP Slave devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one serial port and one PROFIBUS Master DB9F port.
The Modbus (MCM) protocol driver supports Master and Slave implementations of the protocol. All Modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution.
The PROFIBUS DP Master (PDPM) protocol driver supports Master implementations of the protocol on either a Mono-Master or Multi-Master network.
Product Applications
The MCM-PDPM modules are the ideal solution for the many applications where Modbus connectivity can be used to integrate a PROFIBUS DP Slave device into a system.
The Modbus Master/Slave gateway is a powerful module designed with Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Slave device support, the module provides a very powerful interface to the many PROFIBUS devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing
.
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration Data Area
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Modbus Protocol Specifications
The Modbus driver provides access to an internal database of 4000 registers (words), with extensive support provided for both the Master and the Slave implementations of the protocol. The serial port(s) on the gateway can be individually configured to support the Modbus protocol (Master or Slave, RTU or ASCII, Baud Rate, etc).
|
General Parameters - Modbus Protocol
|
|
Type
|
Specifications
|
|
Communication parameters
|
Baud Rate: 110 to 115K baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 ms
|
|
Error Checking
|
RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
|
|
Floating Point
|
Floating point data movement supported, including configurable support for Enron implementation
|
|
Function Codes
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits
16 : Write Multiple Data Register
|
|
Modbus Master
|
|
Type
|
Specifications
|
|
Command List
|
Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
|
|
Status Data
|
Error codes are provided on an individual command basis, as well as a slave status list is maintained per active Modbus Master port.
|
|
Polling of command list
|
Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
|
|
Modbus Slave
|
|
Type
|
Specifications
|
|
Node address
|
1 to 247 - software selectable
|
|
Status Data
|
Error codes, counters and port status available per configured slave port. Status data is all pre-mapped in the module
|
PROFIBUS DP Master Protocol Specifications
The PROFIBUS Master protocol driver exists as a single port implementation. The driver can be configured as a Class 1 PROFIBUS Master to interface with other PROFIBUS slave devices. The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to both standard as well as extended diagnostic information. The PROFIBUS master port can be used to continuously interface with PROFIBUS slave devices over a serial communication interface (RS-485).
|
General Parameters
|
|
Communication parameters
|
Baud Rate: 9.6 kbit/s - 12 Mbit/s
|
|
Slaves
|
Up to 125 Slaves
|
|
Data I/O
|
Up to 512 cyclic bytes (256 words) input and 512 bytes (256 words) output data
|
|
Command List
|
Read Diag
Global Cmd
Read Cntrs
Reset Cntrs
|
|
Node address
|
0 to 125 (software selectable)
|
|
Status Data
|
Error codes, counters and port status available per configured slave on the network.
|
PDPMV1 Compatibility Notice to PDPM Users
The PDPMV1 product is not backward compatible with the PDPM product due to new enhancements and command structure. The PDPMV1 DPV1 master gateway product provides enhanced features to the PDPM DPV0 gateway product as follows:
- Increased Cyclic IO. The DPPMV1 provides 768 Words of Input and 768 Words of Output.
- ProSoft Configuration Builder (PCB) complete support. The PCB provides module level configuration and integrated PROFIBUS master network configuration support.
- The PDPMV1 master supports DPV1 Class 1 or Class 2 DPV1 features such as: Acyclic communication with slaves for parameterization and other slave settings, Alarm handling, extended diagnostics.
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50 Deg C |
| |
-4 to 122 Deg F |
|
Storage Temperature |
-40 to 85 Deg C |
| |
-40 to 185 Deg F |
| Relative Humidity |
5-95% (w/o condensation) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
Mini-DIN |
| |
RS-232 only |
| |
No hardware handshaking |
|
Ethernet Port |
10Base-T Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports |
Mini-DIN |
| |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS422/485 screw termination included |
|
Port Isolation |
2500V Opto-Isolators |
| |
500V Power Supply Isolation |
|
Shipped with each unit |
Mini-DIN to DB-9M cables per serial port |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB9 to Screw Terminal |
| |
Adaptor (1 or 4, depending on ports) |
|
PROFIBUS Connector
|
DB-9F Standard PROFIBUS connector
|
|
PROFIBUS LED Indicators
|
Tkn - Green
|
|
|
Err - Red
|
|
|
Rdy - Green
|
|
|
Run - Green
|
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class 1, Div 2
Ordering Information
|
5104-MCM-PDP
|
Modbus Master/Slave to PROFIBUS DP Master
|