Harris 5000/5500/6000 RTU Slave Communications Module
3100-HAR
The ProSoft Harris Slave Module allows the user to easily configure one or both ports to be slaves to a Harris M9000 Host based system.
The 3100-HAR (PLC) Harris Slave Module is a single slot solution for the A-B 1771 and platforms. By providing configurable access to both ports, this product provides previously unavailable functionality and versatility.
Features
Simple to Use All module setup and operating controls are performed over the backplane through simple ladder logic and data table configuration. The only software necessary is a standard ladder-programming package.
Hands Off Operation Once the HAR module has been setup for operation, the card provides transparent control and monitoring capabilities. The HAR module, integrated directly into the PLC/SLC rack, forms a tightly integrated and practical solution. Once configured, the module will perform all protocol related functions on a stand-alone basis.
Installation, Set Up and Operation The ProSoft module installs in any slot in a local rack. The product's capabilities are enabled and controlled with simple ladder logic and data table initialization.
Applications
The Harris 5000/5500/6000 Slave Module can be found in mainly in the power industry in the following applications:
- Foreign device data concentrator
- Power equipment monitoring
- Dam operation
Functional Specifications
- Harris 5000/5500/6000 implementation of the protocol
- Full radio, modem and multi-drop support
- Supports RS-232C, RS-422 and RS-485 interfaces
- Communication error codes and counters returned to ladder logic(Slave port)
- Configurable character delay to support VSAT packetizing delays
- Configuration via simple ladder logic
- Supported operational codes:
|
0
|
A/D and accumulator data dump
|
|
3
|
Status check
|
|
4
|
Status change dump
|
|
5
|
Status dump
|
|
6
|
Trip/close control arm
|
|
7
|
Trip/close control operate
|
|
8
|
AGC raise/lower
|
|
9
|
Set point control arm
|
|
10
|
Set point control operate
|
|
11
|
Power fail reset
|
|
12
|
Port on-line status scan
|
|
21
|
Time synchronization (SOE)
|
|
23
|
Time synchronization adjustment
|
|
27
|
Time synchronization (Non-SOE)
|
|
30
|
Set freeze interval
|
- Supports broadcast commands from master register addressing
- Up to 7 ports, each port with:
|
Status
|
Up to 63 words
|
|
Analog
|
Up to 63 words
|
|
12 bit
|
Up to 63 words
|
|
24 bit
|
Up to 34 values
|
|
32 bit
|
Up to 12 values
|
- Communication parameters:
|
Address
|
1 to 63
|
|
Parity
|
None, odd, even
|
|
Stop bit
|
1 or 2
|
|
Baud rate
|
300 to 38.4K
|
|
RTS delays
|
1 ms resolution on and off
|
Hardware Specifications
- Backplane current load
-
3100 module for PLC
- 0.65 A
-
Operating temperature
- 0 to 60 deg C (32 to 140 deg F)
-
Storage temperature
-From -40 to 85 deg C (-40 to 185 deg F)
-
Relative humidity
- 5-95% (w/o condensation)
-
LED Indicators
- Module status
- Backplane transfer status
- Serial port TX/RX activity LED - Serial port error LED status
-
Application serial ports
- DB-25F - 3100 module
- RS232/422/485 jumper selectable
- RS422/485 screw termination included (two per module)
- RS-232 hardware handshaking (RTS/CTS, DTR) - 500V optical isolation from backplane