IEC 60870-5-101 Slave Communication Module
MVI56-101S Edition 2
The IEC 60870-5-101 Slave Serial Communication Module, Edition 2, allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with IEC 60870-5-101 protocol compatible hosts. The module's two powerful and highly-configurable redundant ports allow the many SCADA host systems supporting the IEC protocol to be integrated into the ControlLogix platform. The MVI56-101S Edition 2 Slave module is designed to address the application where a host systems using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. This lastest version offers IEC 60870-5-101Edition 2 protocol features, such as additional datatypes and additional Causes of Transmission (COT) support.
Features and Benefits
The MVI56-101S Edition 2 module is the best way to add IEC 60870-5-101 protocol interface support to the ControlLogix platform. This module has two powerful and highly-configurable IEC 60870-5-101 Slave serial ports, allowing many SCADA and field devices using this IEC protocol to be integrated into the ControlLogix platform.
The module acts as an input/output module between the IEC 60870-5-101 telecontrol network and the Rockwell Automation ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. A 5000-word register space in the module exchanges data between the processor and the telecontrol network.
General Specifications
- Single Slot - 1756 backplane compatible
- The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
- Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
- Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
- Local or remote rack
Applications
The MVI56-101S Slave module is designed to address the application where a host systems using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. As such, the IEC Slave module can be used as a gateway in many SCADA installations in industries such as:
- Power and distribution applications
- Petrochemical
- Water and Gas Applications
- Oil and Gas production
Functional Specifications
The MVI56-101S Edition 2 module accepts commands from an attached master unit. A port configured as a virtual slave permits a remote master to interact with all data contained in the module. This data can be derived from the ControlLogix processor. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. The module can operate in balanced or unbalanced mode.
- User-definable module memory usage
- Storage of IEC time used in module is available in the database
- Protocol implementation conforms to the IEC 60870-5-101 specification with fully configurable parameters
- Priority Queues
- Invalid Bit Monitoring
- Supports Balanced and Unbalanced Mode
- Supports CP24 and CP56 time formats for events
- Event generation configurable per point or data type
Hardware Specifications
|
Application Serial ports (P1, P2)
|
Full hardware handshaking control
Radio, modem, and multi-drop support
RJ45 (DB-9M with supplied cable)
RS-232, 485, and 422 (jumper selectable) 500V optical isolation from backplane
|
|
Software configurable communication parameters
|
Baud rate: 110 to 38,400 baud depending on protocol
Parity: None, Odd or Even
Data Bits: 5, 6, 7, or 8
Stop Bits: 1 or 2
RTS On/Off Delay: 0 to 65535 ms RS-232 handshaking configurable
|
|
CFG Port
|
RJ45 (DB-9M with supplied cable) RS-232 only
|
|
Shipped with unit
|
RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for the debug port
|
Hardware Specifications
|
Specification
|
Description
|
|
Backplane Current Load
|
800 mA maximum @ 5 Vdc
|
|
Operating Temperature
|
0° C to 60° C (32° F to 140° F)
|
|
Storage Temperature
|
-40° C to 85° C (-40° F to 185° F)
|
|
Shock:
|
30g Operational
50g non-operational Vibration: 5 g from 10 to 150 Hz
|
|
Relative Humidity
|
5% to 95% RH, (with no condensation)
|
|
LED Indicators:
|
Module Status
Backplane Transfer Status
Application Status Serial Activity
|
Ordering Information
| MVI56-101S Edition 2 |
IEC 60870-5-101 Slave Communication Module |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.