PROFIBUS DP Slave
MVI56-PDPS
The MVI56 PROFIBUS DP Slave Communication Module allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with a PROFIBUS DP Master device.
The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful
data transfer capability between the module and Rockwell Automation ControlLogix processors. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.
The MVI56 module Configuration/Debug Serial port connects a PC to the module for configuration, status, monitoring, and troubleshooting (Serial cable is included
with product shipment). After editing on a PC, a configuration file is downloaded and stored on the MVI56 module.
The PROFIBUS DP Slave gives access to the unit's input and output images with up to 244 bytes of Input and Output data, for a maximum of 400 bytes total. These Input and Output data blocks are mapped by the user within the inRAx module's data memory allowing maximum flexibility and data transfer with other protocols.
Applications
With the growing usage of the PROFIBUS DP protocol in the industrial marketplace, this product has a wide variety of application uses. Industries that use this technology include:
- Power and distribution applications
- Petrochemical
- Water and Gas Applications
- SCADA and DCS applications
Functional Specifications
PROFIBUS Slave
- Communication parameters
- Baud Rate: 9.6 kbit/s12 Mbit/s
- Supported I/O length
- Up to 244 bytes Input data
- Up to 244 bytes Output data
- Total not to exceed 400 bytes.
- Freeze Mode
- Sync Mode
- Auto Baud Setting
- Configurable Parameters
- PROFIBUS Node Address: 0 to 125
- Data byte swapping
- Action on loss of PROFIBUS connection
- Comm Fail Timeout Multiplier
- Status Data location in Internal Database
- Status Data
- PROFIBUS Status Data for slave
- Physical Connection
- PROFIBUS Connector
- Standard PROFIBUS DB-9F communication connector. Cable connection matches PROFIBUS pin out specification.
Hardware Specifications
Hardware Specifications
|
Backplane Current Load
|
800 mA @ 5 V
|
|
Operating Temperature
|
0 to 60 Deg C
|
|
|
32 to 140 Deg F
|
|
Storage Temperature
|
-40 to 85 Deg C
|
|
|
-40 to 185 Deg F
|
|
Relative Humidity
|
5-95% (w/o condensation)
|
|
LED Indicators
|
Module Status
|
|
|
Backplane Transfer Status
|
|
|
SerialPort Activity LED
|
|
|
Serial Activity and Error LED Status
|
|
|
Master Status Operations Network Drop Communication Master Token-Hold
|
|
|
Master database configuration
|
|
Configuration Serial Port (PRT1)
|
DB-9M PC Compatible
|
|
|
RS-232 only
|
|
|
No hardware handshaking
|
|
PROFIBUS Slave Port
|
Standard PROFIBUS DB-9F communication connector. Cable connection matches PROFIBUS pin out specification.
|
|
|
|
|
|
|
Ordering Information
| MVI56-PDPS |
PROFIBUS DP Slave |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.
Sales and Support:
|