Modbus TCP/IP Communications Module

MVI71-MNET

The MVI71 Modbus TCP/IP Communication Module is designed to allow PLC processors to interface easily with other Modbus TCP/IP protocol-compatible devices.

Compatible devices include not only Modicon processors (which support the Modbus TCP/IP protocol) but also a wide assortment of other clients and server devices.

Features and Benefits

The MVI71-MNET module is a single slot solution that provides a powerful connection between Rockwell Automation's PLC processor and Modbus TCP/IP network applications.

The TCP/IP Modbus network applications include those networks hosted by Modicon Quantum processors, networks controlled by operator interface software packages, and the growing number of manufactured devices that support this protocol. The module acts as an input/output module between the Modbus TCP/IP network and the Rockwell Automation backplane. The data transfer from the processor is asynchronous from the actions on the Modbus TCP/IP network. A 5000-word register space in the module exchanges data between the processor and the Modbus TCP/IP network.

  • Support for the storage and transfer of up to 5000 registers to/from the PLC processor using the block transfer or side-connect interface
  • User-definable module memory usage
  • 10/100 MB Ethernet compatible interface
  • Configurable parameters for the client including a minimum response delay of 0 to 65535 mSec and floating point support

General Specifications

  • Single Slot - 1771 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.

Applications

With the growing trend of Ethernet technology in the industrial marketplace, this product has a wide variety of application uses.

  • Food processing
  • Petrochemical
  • Pulp and paper
  • Automobile manufacturing
  • Water and Wastewater
  • Oil and Gas
  • Power and Electric

Functional Specifications

General Protocol specifications

Type

Specifications

Floating Point Data

Floating point data movement supported, including configurable support for Enron implementation

Modbus Server Protocol Specifications

The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000.

Modbus Server Protocol Specifications

The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000.

General

  • Supports five independent server connections for Service Port 502
  • Supports five independent server connections for Service Port 2000

Status Data

Error codes, counters, and port status available

Modbus Function Codes

Code

Description

1:

Read Output Status

2:

Read Input Status

3:

Read Multiple Data Registers

4:

Read Input Registers

5:

Write Single Bit

6:

Write Single Data Register

15:

Write Multiple Bits

16:

Write Multiple Data Register

Modbus TCP/IP Client

The client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.

One client connection available (connect up to 100 servers/devices with 100 commands)

Hardware Specifications

Form Factor

Single Slot - 1771 chassis compatible

 

BTR/BTW data transfer

 

Local or remote rack

Backplane Current Load

800 mA @ 5V

Operating Temperature

0 to 60 deg C (32 to 140 deg F)

Storage Temperature

-40 to 85 deg C (-40 to 185 deg F)

Shock

30g operational

 

50g non-operational

Vibration

5g from 10 - 10150 Hz

Relative Humidity

5 to 95% (w/o condensation)

LED Indicators

Module status

 

Backplane transfer status

 

Application status

 

Error LED status

 

Link and Activity LED

Configuration Port (CFG)

DB-9M PC compatible

 

RS-232

 

Hardware handshaking

Ethernet Port

RJ45 connector

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Shipped with unit

RJ45 connector

 

RJ45 to DB-9M cable

 

6-foot RS-232 configuration cable

Ethernet and CFG Ports

 

Ethernet Port

RJ45 connection
10/100 Mbit Ethernet support (auto-sensing)
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

CFG Port

RJ45 (DB-9M with supplied cable)
RS-232 only

Shipped with unit

RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for debug port

Ordering Information

MVI71-MNET Modbus TCP/IP Communications Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Home : Products : Support : Distributors : Services : News/Events : Contact Us : ProSoft Tested