Harris 5000/5500/6000 RTU Slave Module
3150-HAR
The 3150-HAR (SLC) Harris Slave Module is a single slot solution for the A-B 1746 platforms. By providing configurable access to both ports, this product provides previously unavailable functionality and versatility.
Features
All module setup and operating controls are performed over the backplane through simple ladder logic and data table configuration. The only software necessary is a standard ladder-programming package.
Hands Off Operation
Once the HAR module has been setup for operation, the card provides transparent control and monitoring capabilities. The HAR module, integrated directly into the PLC/SLC rack, forms a tightly integrated and practical solution. Once configured, the module will perform all protocol related functions on a stand-alone basis.
Installation, Set Up and Operation
The ProSoft module installs in any slot in a local rack. The product's capabilities are enabled and controlled with simple ladder logic and data table initialization.
Applications
The Harris 5000/5500/6000 Slave module can be found in mainly in the power industry in the following applications:
- Foreign device data concentrator
- Power equipment monitoring
- Dam operation
Functional Specifications
- Harris 5000/5500/6000 implementation of the protocol
- Full radio, modem and multi-drop support
- Supports RS-232C, RS-422 and RS-485 interfaces
- Communication error codes and counters returned to ladder logic (slave port)
- Configurable character delay to support VSAT packetizing delays
- Supports broadcast commands from master register addressing
- Configuration via simple ladder logic
- Supported operation codes:
|
0
|
:
|
A/D and Accumulator Data Dump
|
|
3
|
:
|
Status Check
|
|
4
|
:
|
Status Change Dump
|
|
5
|
:
|
Status Dump
|
|
6
|
:
|
Trip/Close Control Arm
|
|
7
|
:
|
Trip/Close Control Operate
|
|
8
|
:
|
AGC Raise/Lower
|
|
9
|
:
|
Set Point Control Arm
|
|
10
|
:
|
Set Point Control Operate
|
|
11
|
:
|
Power Fail Reset
|
|
12
|
:
|
Port On-Line Status Scan
|
|
21
|
:
|
Time Synchronization (SOE)
|
|
23
|
:
|
Time Synchronization Adjustment
|
|
27
|
:
|
Time Synchronization (Non-SOE)
|
|
30
|
:
|
Set Freeze Interval
|
|
Status
|
:
|
Up to 63 words
|
|
Analog
|
:
|
Up to 63 words
|
|
12 bit
|
:
|
Up to 63 words
|
|
24 bit
|
:
|
Up to 34 values
|
|
32 bit
|
:
|
Up to 12 values
|
|
Address
|
:
|
1 to 63
|
|
Parity
|
:
|
None, Odd, Even
|
|
Stop Bit
|
:
|
1 or 2
|
|
Baud rate
|
:
|
300 to 38.4K
|
|
RTS Delays
|
:
|
1 ms resolution on and off
|
Hardware Specifications
- Backplane current load
-
3150 module for SLC
- 5V @ 0.15 A - 24 V @ 0.040 A
-
Operating temperature
- From 0° C to 60° C (32° F to 140° F)
-
Storage temperature
-From -40° C to 85° C (-40° F to 185° F)
-
Relative humidity
- From 5% to 95% (without condensation)
-
LED indicators
- Module Status
- Backplane transfer status
- Serial port TX/RX activity LED - Serial port error LED status
-
Application Serial ports
- DB-25F - 3100 module
- DB-9M - 3150 module
- RS232/422/485 jumper selectable
- RS422/485 screw termination included (two per module)
- RS-232 hardware handshaking (RTS/CTS, DTR) - 500 V Optical isolation from backplane
Ordering Information
| 3150-HAR |
Harris 5000/5500/6000 RTU Slave Module |
| |
|
| To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here. |
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.
Sales and Support:
|