ProSoft Technology, Inc.
Home > Products > for Rockwell Automation > Protocol > Serial > IEC 60870-5-101 > MVI56-101S Edition 2
Printable Page
 

Search | Clear


IEC 60870-5-101 Slave Communication Module

MVI56-101S Edition 2

The IEC 60870-5-101 Slave Serial Communication Module, Edition 2, allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with IEC 60870-5-101 protocol compatible hosts. The module's two powerful and highly-configurable redundant ports allow the many SCADA host systems supporting the IEC protocol to be integrated into the ControlLogix platform. The MVI56-101S Edition 2 Slave module is designed to address the application where a host systems using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. This lastest version offers IEC 60870-5-101Edition 2 protocol features, such as additional datatypes and additional Causes of Transmission (COT) support.

Features and Benefits

The MVI56-101S Edition 2 module is the best way to add IEC 60870-5-101 protocol interface support to the ControlLogix platform. This module has two powerful and highly-configurable IEC 60870-5-101 Slave serial ports, allowing many SCADA and field devices using this IEC protocol to be integrated into the ControlLogix platform.

The module acts as an input/output module between the IEC 60870-5-101 telecontrol network and the Rockwell Automation ControlLogix backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the network. A 5000-word register space in the module exchanges data between the processor and the telecontrol network.

General Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file included.
  • Configuration data obtained from configuration text file downloaded to module. Sample configuration file included
  • Local or remote rack

Applications

The MVI56-101S Slave module is designed to address the application where a host systems using the IEC 60870-5-101 protocol must communicate with a ControlLogix processor. As such, the IEC Slave module can be used as a gateway in many SCADA installations in industries such as:

  • Power and distribution applications
  • Petrochemical
  • Water and Gas Applications
  • Oil and Gas production

Functional Specifications

The MVI56-101S Edition 2 module accepts commands from an attached master unit. A port configured as a virtual slave permits a remote master to interact with all data contained in the module. This data can be derived from the ControlLogix processor. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs. The module can operate in balanced or unbalanced mode.

  • User-definable module memory usage
  • Storage of IEC time used in module is available in the database
  • Protocol implementation conforms to the IEC 60870-5-101 specification with fully configurable parameters
  • Priority Queues
  • Invalid Bit Monitoring
  • Supports Balanced and Unbalanced Mode
  • Supports CP24 and CP56 time formats for events
  • Event generation configurable per point or data type

Hardware Specifications

Application Serial ports
(P1, P2)

Full hardware handshaking control
Radio, modem, and multi-drop support
RJ45 (DB-9M with supplied cable)
RS-232, 485, and 422 (jumper selectable)
500V optical isolation from backplane

Software configurable
communication parameters

Baud rate: 110 to 38,400 baud depending on protocol
Parity: None, Odd or Even
Data Bits: 5, 6, 7, or 8
Stop Bits: 1 or 2
RTS On/Off Delay: 0 to 65535 ms
RS-232 handshaking configurable

CFG Port

RJ45 (DB-9M with supplied cable)
RS-232 only

Shipped with unit

RJ45 to DB-9M adapter cable and 6-foot RS-232 configuration cable for the debug port

Hardware Specifications

Specification

Description

Backplane Current Load

800 mA maximum @ 5 Vdc

Operating Temperature

0° C to 60° C (32° F to 140° F)

Storage Temperature

-40° C to 85° C (-40° F to 185° F)

Shock:

30g Operational
50g non-operational
Vibration: 5 g from 10 to 150 Hz

Relative Humidity

5% to 95% RH, (with no condensation)

LED Indicators:

Module Status
Backplane Transfer Status
Application Status
Serial Activity

Ordering Information

MVI56-101S Edition 2 IEC 60870-5-101 Slave Communication Module
   
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

 

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe/Middle East/Africa
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

 

Home : Products : Support : Distributors : Services : News/Events : Contact : ProSoft Tested