IEC60870-5-104 Server to DH-485 Communication Module
5201-104S-DH485
Product Description
The ProLinx family IEC60870-5-104 Server to DH-485 communications module (5201-104S-DH485) creates a powerful connection between devices on an IEC 104 Server network and a DH-485 device. The module is a stand-alone DIN rail-mounted protocol gateway that provides one DH-485 configurable serial port and one Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The ProLinx DH485 protocol driver supports the Master and the Slave modes of the protocol, providing powerful data transfer capability with Rockwell Automation PLCs and HMIs. User configurable data mapping make the interface an easy to use and powerful data transfer tool.
Product Applications
The 104S-DH485 modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate a DH-485 device into a system.
The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to an IEC 104 master device. In combination with the DH-485 device support, the module provides a very powerful interface to the many DH-485 devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
IEC 60870-5-104v2 Server Protocol Specifications
Operating in the Server mode, the protocol driver accepts commands an IEC 60870-5-104 Client to read/write data stored in the module's internal registers.
The 104S module acts as a gateway between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include:
- User-definable module memory usage
- Protocol implementation conforms to the IEC 60870-5-104 specification with fully configurable parameters
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
|
IEC 60870-5-104v2 Server
|
|
Configurable Parameters
|
Override StartDT
Clear queue on close
t1 timeout set value
t2 timeout set value
t3 timeout set value
k (maximum queue)
w (latest ack threshold) Time DB Offset
|
|
Status Data
|
The status data include the following: t0, t1, t2 and t3 timeout , Bad Address Errors, SocketState, Host IP Address.
|
|
Supported Data Points
|
M_SP_NA
M_DP_NA
M_ST_NA
M_ME_NA
M_ME_NB
M_IT_NA
C_SC_NA
C_DC_NA
C_RC_NA
C_SE_NA C_SE_NB
|
DH485 Master/Slave Serial Port Specifications
The DH485 protocol in its native form is a peer to peer token passing network. The ProLinx DH485 driver accesses the network functioning either as a Master or as a Slave.
In the Master mode, the ProLinx DH485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH485 devices, such as SLC processors. When configured in this mode, data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
|
General Protocol Information
|
|
Type
|
Specifications
|
|
DH485 Modes
|
Full-Duplex and Half-Duplex
|
|
Error Checking
|
BCC and CRC
|
|
User configurable Communication parameters
|
Local Station ID: 0 to 31
Port 0 Baud Rate: 110 to 38.4K baud
Port 1,2,3 Baud Rate: 110 to 115K baud
Stop Bits : 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd RTS Timing delays: 0 to 65535 ms
|
DH485 Slave Mode
In the Slave mode, the module accepts commands from one or more Masters to read/write data stored in the module's internal data memory. In this mode, the ProLinx unit is answering DH485 commands and has the appearance of an SLC processor to the network.
|
DH485 Functioning as a Slave
|
|
Type
|
Specifications
|
|
Data File
|
Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
|
|
Supported Commands
|
0x01 P3_UNPROTECTED_READ_CMD
0x06 P3_DIAGNOSTIC_CMD
0x00 P3_DIAG_LOOP_FUNC
0x01 P3_DIAG_READ_FUNC
0x03 P3_DIAG_STATUS_FUNC
0x07 P3_DIAG_RESET_FUNC
0x09 P3_DIAG_READ_LINK_FUNC
0x0A P3_DIAG_SET_LINK_FUNC
0x08 P3_UNPROTECTED_WRITE_CMD
0x0F P3_TYPED_RW_CMD
0xA1 P3_TYPED_READ_2ADD_FUNC
0xA2 P3_TYPED_READ_3ADD_FUNC
0xA9 P3_TYPED_WRITE_2ADD_FUNC 0xAA P3_TYPED_WRITE_3ADD_FUNC
|
DH485 Master Mode
In the Master mode, the ProLinx DH485 driver will actively gather data from other devices on the network, controlling the read/write data transfer between the gateway and other DH485 devices, such as SLC processors. When configured in this mode, data transfer can be initiated and executed with the other devices without any ladder logic being required in the Rockwell Automation slave hardware.
These commands are user-configured in the module via the master command list received from the configuration file. Command status is available in the status data block for each individual command in the command list status data area. The location of this status block in a module's internal database is user-defined.
|
DH485 Functioning as a Master
|
|
Type
|
Specifications
|
|
Configurable Parameters per Master port
|
Min Command Delay
Command Error DB Offset
Response Timeout Token Hold Factor
|
|
Command List
|
Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count
|
|
Status Data
|
Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50°C |
| |
-4 to 122°F |
|
Storage Temperature |
-40 to 85°C |
| |
-40 to 185°F |
| Relative Humidity |
5% to 95% (non-condensing) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
DB-9M RS-232 only |
| |
No hardware handshaking |
Ethernet Port (Ethernet protocol gateways only) |
10Base-T half duplex RJ45 Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports (Serial protocol gateways only) |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor |
| |
Note: The number of serial application ports depends on the module type, and the combination of protocols. |
|
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
| |
3000V DC min. isolation port to ground and port to logic |
|
Shipped with each unit |
Mini-DIN to DB-9M serial cables |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) |
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2
Ordering Information
|
5201-104S-DH485
|
IEC60870-5-104 Server to DH-485
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.