IEC60870-5-104 Server to PROFIBUS DPV0 Slave Gateway
5205-104S-PDPS (104S Version 3 with Extended Edition 2 Support)
5205-TS-104S-PDPS (104S Version 2 with Original Edition 2 Support and Time-Stamping Support)
Product Description
The IEC 60870-5-104 Server to PROFIBUS DP Slave Gateway creates a powerful connection between devices on an IEC 104 network and PROFIBUS DP Master devices. This stand-alone DIN-rail mounted gateway provides one PROFIBUS DPV0 Slave DB9F port and one IEC 104 Server Ethernet port.
The IEC 104S gateway accepts and responds to commands from a network-connected IEC 104 Client (Master) and can also autonomously generate unsolicited messages for cyclic or event-driven data transmission. Firmware versions 3.00 and later support a wider range of IEC 60870-5-104 Edition 2 data types and Causes of Transmission than previously offered.
The PROFIBUS DP Slave protocol (PDPS) supports the PROFIBUS DP Version 0 implementation, providing powerful data transfer capability between the ProLinx gateway and a PROFIBUS DP Master. With relatively few options to adjust, the PROFIBUS DP Slave configuration is quick, simple, and easily accomplished using the provided ProSoft Configuration Builder software.
Product Applications
|
Features
|
Benefits
|
|
Powerful network integration
|
-
Move data between dissimilar networks using two communication protocols on one gateway
-
Protocols share access to a common memory database to exchange data between networks
-
View diagnostic data for both networks from a single configuration/debug port
|
|
EC 60870-5-104 Server protocol Interface (version 3)
|
-
Adds an IEC 60870-5-104 Server (Slave) Input and Output link to a PROFIBUS DP network
-
IEC 60870-5-104, extended Edition 2 Data Types and Causes of Transmission Support
-
Advanced Event Buffer control parameters allow better data bandwidth utilization
|
|
PROFIBUS DPV0 Slave protocol interface
|
-
Adds PROFIBUS DPV0 Slave device monitoring and control to a IEC 60870-5-104 network
-
Easy configuration - GSD file provided
-
PROFIBUS Slave status may be stored in gateway database and retrieval by either protocol
|
|
ProSoft Configuration Builder software included
|
-
Graphical drag-and-drop configuration tool for simple module configuration
-
Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics
-
View module database contents through serial connection to a desktop PC
|
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing communication and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations into new projects.
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
IEC 60870-5-104 Server Protocol Specifications
Operating in the Server mode, the protocol driver accepts commands from an IEC 60870-5-104 to read/write data stored in the gateway's internal registers.
The 104S acts as a gateway between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include:
- User-definable module memory usage
- Protocol implementation conforms to the IEC 60870-5-104 specification with fully configurable parameters
The 104S gateway accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
|
IEC 60870-5-104v3 Server
|
|
Configurable Parameters
|
Override StartDT
Clear queue on close
t1 timeout set value
t2 timeout set value
t3 timeout set value
k (maximum queue)
w (latest ack threshold) Time DB Offset
|
|
Status Data
|
The status data include the following: t0, t1, t2 and t3 timeout , Bad Address Errors, SocketState, Host IP Address.
|
|
Supported Data Points
|
M_SP_NA
M_DP_NA
M_ST_NA
M_ME_NA
M_ME_NB
M_ME_NC
M_IT_NA
M_BO_NA
C_SC_NA
C_DC_NA
C_RC_NA
C_SE_NA
C_SE_NB
C_SE_NC C_BO_NA
|
PROFIBUS DP Slave Specifications
The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 200 bytes of Input data and 200 bytes of Output data. These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.
|
General Parameters
|
|
GSD File
|
PRLX05A5.GSD Downloadable from ftp site
|
|
PROFIBUS Specifications
|
|
Communication parameters
|
Baud Rate: 9.6 kbit/s - 12 Mbit/s
|
|
Supported I/O length
|
200 bytes Input data 200 bytes Output data
|
|
Supported PROFIBUS DP features
|
PROFIBUS V0 Slave using Siemens SPC3 chipset
Freeze Mode
Sync Mode Auto Baud Setting
|
|
Configurable Parameters
|
- PROFIBUS Node Address: 1 to 125
- Data byte swapping
- Action on loss of PROFIBUS connection
- Comm Fail Timeout Multiplier - Status Data location in Internal Database
|
|
Status Data
|
Status data is available through the debug menu. The status information includes diagnostic data, input and output counters and module state.
|
Important Note: The slave node address is set to 126 by default in the module configuration file. The default node address must be changed to a valid address between 1-125 by the user for the slave to function on the PROFIBUS network.
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50°C |
| |
-4 to 122°F |
|
Storage Temperature |
-40 to 85°C |
| |
-40 to 185°F |
| Relative Humidity |
5% to 95% (non-condensing) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
DB-9M RS-232 only |
| |
No hardware handshaking |
Ethernet Port (Ethernet protocol gateways only) |
10Base-T half duplex RJ45 Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports (Serial protocol gateways only) |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor |
| |
Note: The number of serial application ports depends on the module type, and the combination of protocols. |
|
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
| |
3000V DC min. isolation port to ground and port to logic |
|
Shipped with each unit |
Mini-DIN to DB-9M serial cables |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) |
|
PROFIBUS Connector
|
DB-9F Standard PROFIBUS connector
|
|
PROFIBUS LED Indicators
|
Active - Green
|
|
|
Error - Red
|
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2
PNO Certified - PROFIBUS Test Center
Ordering Information
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.