Modbus TCP/IP to IEC60870-5-104 Server Communication Module
5201-MNET-104S
Product Description
The ProLinx family Modbus TCP/IP to IEC60870-5-104 Server communications module (5201-MNET-104S) creates a powerful connection between devices on a Modbus TCP/IP network and IEC 104 master devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one Ethernet port.
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.
The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.
Product Applications
The MNET-104S modules are the ideal solution for the many applications where Modbus TCP/IP connectivity can be used to integrate an IEC 104 master device into a system.
The Modbus TCP/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to other Modbus devices (Modicon processors and many others). In combination with the IEC60870-5-104 Server device support, the module provides a very powerful interface to the many IEC 104 master devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
IEC 60870-5-104 Server Protocol Specifications
Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers.
The 104S module acts as a gateway between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces. General specifications include:
- User-definable module memory usage
- Protocol implementation conforms to the IEC 60870-5-104 specification with fully configurable parameters
The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.
|
IEC 60870-5-101 Server
|
|
Configurable Parameters
|
Override StartDT
Clear queue on close
t1 timeout set value
t2 timeout set value
t3 timeout set value
k (maximum queue)
w (latest ack threshold) Time DB Offset
|
|
Status Data
|
The status data include the following: t0, t1, t2 and t3 timeout , Bad Address Errors, SocketState, Host IP Address.
|
|
Supported Data Points
|
M_SP_NA
M_DP_NA
M_ST_NA
M_ME_NA
M_ME_NB
M_IT_NA
C_SC_NA
C_DC_NA
C_RC_NA
C_SE_NA C_SE_NB
|
Modbus TCP/IP Protocol Specifications
The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks.
Modbus TCP/IP Port Specifications
Server
The MNET module supports server functionality using the reserved Modbus TCP/IP service port 502, as well as service port 2000 to support the TCP/IP encapsulated Modbus protocol that is supported by several HMI manufacturers. Services supported in the module permit client applications (i.e., HMI software packages, Quantum processors, etc.) to read from and write to the module's database.
Data in the module's internal database is accessible for read and write operations by any node on the network supporting the MBAP (service port 502) or MNET (service ports 2000/2001) TCP/IP protocols.
There is no configuration of the MNET module required to implement Server functionality other than setting up the network and database parameters in the user configuration file.
|
Modbus TCP/IP Server
|
|
Type
|
Specification
|
|
General
|
The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000. - Supports up to five (5) independent server connections for Service Port 502
- Supports up to five (5) independent server connections for Service Port 2000
|
|
Configurable Parameters
|
Module IP Address Modbus address offsetting
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
Client
The module supports a client connection on the TCP/IP network to interface with processors (and other server based devices) using a user constructed command list of up to 100 entries.
|
Modbus TCP/IP Client
|
|
Type
|
Specification
|
|
General
|
The client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.
- One client connection available (connect up to 100 servers/devices with 100 commands)
|
|
Configurable parameters
|
Number of active commands (Up to 100 for client)
Min Command Delay
Response Timeout
Retry Count Command Error Pointer
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
|
Command List
|
Up to 100 commands on the Client port, each fully configurable for function, Server IP address, Service Port, register to/from addressing and word/bit count
|
|
Status Data
|
Error codes available on an individual command basis.
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50 Deg C |
| |
-4 to 122 Deg F |
|
Storage Temperature |
-40 to 85 Deg C |
| |
-40 to 185 Deg F |
| Relative Humidity |
5-95% (w/o condensation) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
Mini-DIN |
| |
RS-232 only |
| |
No hardware handshaking |
|
Ethernet Port |
10Base-T Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports |
Mini-DIN |
| |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS422/485 screw termination included |
|
Port Isolation |
2500V Opto-Isolators |
| |
500V Power Supply Isolation |
|
Shipped with each unit |
Mini-DIN to DB-9M cables per serial port |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB9 to Screw Terminal |
| |
Adaptor (1 or 4, depending on ports) |
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class 1, Div 2
Ordering Information
|
5201-MNET-104S
|
Modbus TCP/IP to IEC60870-5-104 Server
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.