Modbus TCP/IP to CC-Link Local and Intelligent Station Gateway

5209-MNET-CCLINK

Product Description

The ProSoft Technology Modbus TCP/IP to CC-Link communication gateway allows Schneider Electric control platform users to integrate CC-Link Master compatible products with existing Modbus TCP/IP control networks.

The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.

The CC-Link protocol driver acts as a Local or Intelligent Station, which enables easy connection to the CC-Link Master-controlled network for data transfer. Configuration options allow the gateway to occupy up to four (4) stations on the CC-Link network. Transient Messaging capability increases overall I/O data transfer capacity by more than 8,000 words. When configured as a Local Station, the gateway allows read-only viewing of the entire CC-Link Master cyclic database from all configured slave on the CC-Link network.

Product Applications

Features Benefits
Powerful network integration
  • Communicate between dissimilar networks
  • A shared 10.000-word database exchanges information from devices on both networks
  • Allows integration of Modbus TCP/IP-based systems into a CC-Link Master-controlled network
Modbus TCP/IP
  • Client and/or Server communication configurations supported
  • Five simultaneous Server connections on TCP/IP Service Port 502 and five additional Server connections on any unreserved service port (typically TCP/IP Service Port 2000)
  • One Client connection supports up to 100 commands to interface with processors or other Server-based devices
CC-Link Intelligent or Local Station
  • Compatible with CC-Link Version 1.10
  • Transient Message support for peer station communication adds more than 8,000 words of additional I/O data transfer capacity
  • Supports up to 4 occupied slave stations with 4 data words and 32 data bits per station
  • As a Local Station, provides a read-only list of all network slave cyclic and status data
  • CC-Link Partner Association (CLPA) Certification
Backed by ProSoft Technology
  • 20-year history of delivering high-quality, reliable solutions designed with you in mind
  • Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support help you get going sooner and stay running longer
  • Three-Year Warranty ensures reliability and protects against equipment failures
  • Free ProSoft Software tools tightly integrated with our gateway hardware...a simple and quick, total solution to help you make our gateways fit your applications
Configuration
ProSoft Configuration Builder (PCB) provides a PC-based software configuration solution for quick and easy management of gateway configuration files, as well as viewing gateway and network diagnostics. The CC-Link Setup Guide and sample configuration provide a quick and easy example with step by step instructions on how to move data from one network to the other.

Functional Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration File

This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.

Modbus TCP/IP Protocol Specifications

The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks.

Modbus TCP/IP Port Specifications

Server

The MNET module supports server functionality using the reserved Modbus TCP/IP service port 502, as well as service port 2000 to support the TCP/IP encapsulated Modbus protocol that is supported by several HMI manufacturers. Services supported in the module permit client applications (i.e., HMI software packages, Quantum processors, etc.) to read from and write to the module's database.

Data in the module's internal database is accessible for read and write operations by any node on the network supporting the MBAP (service port 502) or MNET (service ports 2000/2001) TCP/IP protocols.

There is no configuration of the MNET module required to implement Server functionality other than setting up the network and database parameters in the user configuration file.

Modbus TCP/IP Server

Type

Specification

General

The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000.
- Supports up to five (5) independent server connections for Service Port 502

- Supports up to five (5) independent server connections for Service Port 2000

Configurable Parameters

Module IP Address
Modbus address offsetting

Modbus Commands supported

1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits
16 : Write Multiple Data Register

Client

The module supports a client connection on the TCP/IP network to interface with processors (and other server based devices) using a user constructed command list of up to 100 entries.

Modbus TCP/IP Client

Type

Specification

General

The client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.

- One client connection available (connect up to 100 servers/devices with 100 commands)

Configurable parameters

Number of active commands (Up to 100 for client)
Min Command Delay
Response Timeout
Retry Count
Command Error Pointer

Modbus Commands supported

1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits
16 : Write Multiple Data Register

Command List

Up to 100 commands on the Client port, each fully configurable for function, Server IP address, Service Port, register to/from addressing and word/bit count

Status Data

Error codes available on an individual command basis.

Polling of command list

User configurable polling of commands, including disabled, continuous and on change of data (write only)

CC-Link Protocol Specifications

CC-Link (Control & Communication Link) is an open-standard-based communication protocol that enables easy connection to Mitsubishi and other Master PLCs.

  • CC-Link is one of the dominant protocols used in Asia and is rapidly gaining acceptance worldwide.
  • The ProLinx CC-Link interface is a slave (Local Station or Intelligent Device), which can be connected to a CC-Link Master that controls data transfer.
  • The gateway is a stand-alone, DIN-rail-mounted solution that provides one CC-Link network port with TE-CON7 4P connector and an Ethernet port with RJ45 connector

CC-Link Functional Specifications

CC-Link technology is based on an Application Specific Integrated Circuit (ASIC) designed and provided by Mitsubishi Electric Automation. Each CC-Link station transfers 4 words and 32 bits of I/O data to and from the Master station. The CCLINK gateway can occupy up to 4 consecutive stations on the CC-Link network increasing it's I/O data transfer capacity.

Maximum Number of Occupied Stations

4 stations, consecutive addresses

Maximum Number of Devices per Network

26-64 Devices depending on Local and Slave Stations configured

Device Types Supported

Intelligent Device and Local Station

CC-Link Version supported

CC-Link Version 1.10 cyclic data transmission

Message handling

Cyclic Messages and Transient Messages

Cyclic Data Capacity

24 input data words and 24 output data words. Up to 4 slave stations supporting 4 words/32 bits per slave

Additional I/O Data Transfer Capacity

Transient Messaging extends I/O data transfer capacity by more than 8,000 additional words

Transient Message Commands

System Information, Memory Access Information, RUN, STOP, Line Test, Memory Read, and Memory Write commands

Communication speed

10 Mbps, 5 Mbps, 2.5 Mbps, 625 kbps, 156 kbps

Transmission path format

Bus format (EIA RS485 conformance)

Transmission format

HDLC conformance

Error control system

CRC (X16+X12+X5+1)

Hardware Specifications

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, and Ground terminals
2.5 mm screwdriver blade-sized terminals

Current Load

500 mA max@ 32 VDC max

Operating Temperature

If in compliance with Relative Humidity
-20 to 50°C (-4 to 122°F)

If not in compliance with Relative Humidity
0 to 50°C (32 to 122°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Relative Humidity

5% to 95% (non-condensing)

Dimensions

Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD)

Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

General LED Indicators

Power and General Status
Application Status
Serial Port Activity LED
Serial Activity and Error LED Status

CC-Link LED Indicators

Run (Network Status)
L Run (Data Link Execution)
L Err (Data Link Comm Error)
SD (Sending Data LED)
RD (Receiving Data LED)
ERR (Switch Setting Error)

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port

RJ45 Connector, 10Mbit, half-duplex only
Link and Activity LED indicators
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

CC-Link Interface

Pin

Description

DA

Data Communication line A

DB

Data Communication line B

DG

Digital Ground

SLD

Shield

FG

Frame Ground

Shipped with Each Unit

Mini-DIN to DB-9M serial cable
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
CC-Link to Terminal Block connector

Click here for dimensions diagram

Conformance Testing

Conformance testing through the CC-Link partner Association (CLPA) ensures that the gateway meets the performance specifications required to become CC-Link certified.

Ordering Information

5209-MNET-CCLINK

Modbus TCP/IP to CC-Link Local & Intelligent Station Gateway

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe/Middle East/Africa
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

Image Gallery




Home : Products : Support : Distributors : Services : News/Events : Contact : ProSoft Tested