Modbus TCP/IP to Siemens 3964R Gateway
5202-MNET-S3964R4
Product Description
The ProLinx Modbus TCP/IP to Siemens 3964R Gateway allows point-to-point communication between a Modbus TCP/IP Ethernet network and 3964R serial communication partners.
The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.
The 3964R protocol was designed by Siemens for bi-directional data communication. It provides a point-to-point, serial interface connection that supports assigning high-priority or low-priority read and write access to each communication partner. This reduces initialization errors and improves data messages, increasing its versatility and range of possible applications.
Product Applications
|
Features
|
Benefits
|
|
Powerful network integration
|
-
Communicate between dissimilar networks
-
Shared database exchanges information from devices on both networks
-
View diagnostics between both networks
|
|
Modbus TCP/IP protocol interface
|
-
Modbus TCP/IP adds Ethernet capability to one of the most widely used industrial protocols
-
Suitable for SCADA and foreign device interface applications
-
Floating point data movement supported, including configurable support for Enron and Daniel floating point applications
-
Communicate with programmable controllers, intelligent devices, sensors and instruments
-
Allows PCs and HMIs to monitor field devices
|
|
S3964R Protocol Interface
(on four serial ports)
|
-
Integrates with Schneider Electric baggage-handling projects using Siemens 3964R protocol
-
Bi-directional data communication with communication partner high/low priority assignment
-
Support simultaneous connections to as many as four 3964R communication partners
-
Shares common database with Modbus TCP/IP network
|
|
Backed by ProSoft Technology
|
-
20-year history of delivering high-quality, reliable solutions designed with you in mind
-
Free, unlimited, worldwide Technical Support by phone anytime for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer
-
Three-Year Warranty ensures reliability and protects against equipment failures
-
Free ProSoft Software tools tightly integrated with our hardware...a simple and quick, total solution to help you make our products fit your applications
|
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
Modbus TCP/IP Protocol Specifications
The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks.
Modbus TCP/IP Port Specifications
Server
The MNET module supports server functionality using the reserved Modbus TCP/IP service port 502, as well as service port 2000 to support the TCP/IP encapsulated Modbus protocol that is supported by several HMI manufacturers. Services supported in the module permit client applications (i.e., HMI software packages, Quantum processors, etc.) to read from and write to the module's database.
Data in the module's internal database is accessible for read and write operations by any node on the network supporting the MBAP (service port 502) or MNET (service ports 2000/2001) TCP/IP protocols.
There is no configuration of the MNET module required to implement Server functionality other than setting up the network and database parameters in the user configuration file.
|
Modbus TCP/IP Server
|
|
Type
|
Specification
|
|
General
|
The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000. - Supports up to five (5) independent server connections for Service Port 502
- Supports up to five (5) independent server connections for Service Port 2000
|
|
Configurable Parameters
|
Module IP Address Modbus address offsetting
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
Client
The module supports a client connection on the TCP/IP network to interface with processors (and other server based devices) using a user constructed command list of up to 100 entries.
|
Modbus TCP/IP Client
|
|
Type
|
Specification
|
|
General
|
The client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.
- One client connection available (connect up to 100 servers/devices with 100 commands)
|
|
Configurable parameters
|
Number of active commands (Up to 100 for client)
Min Command Delay
Response Timeout
Retry Count Command Error Pointer
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
|
Command List
|
Up to 100 commands on the Client port, each fully configurable for function, Server IP address, Service Port, register to/from addressing and word/bit count
|
|
Status Data
|
Error codes available on an individual command basis.
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
Siemens S3964R
- Supported baud rates: 600 through 19200 are typical; up to 115200 is possible
- Supported protocols: 3964 with RK512, 3964 without RK512
- Priority setting to define the behavior of the protocol in case of an initialization conflict.
- Offers four independently configurable serial ports. Each port can communicate using 3964R protocol with or without RK512 formatting. Each port can be set to use an RS-232 or RS-422 serial signal interface. The ports operate independently from each other and each port is assigned its own space in the gateway's user memory database.
- When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can initiate or receive DB-SEND instructions.
- RK512 mode on Port 0, Port 1, Port 2, and Port 3 allow evaluation of RK512 header information: DB data block, DW data word, Coordination Byte 9, and CPU Coordination Byte 10.
- When using S3964R without RK512 communications mode, Port 0, Port 1, Port 2, and Port 3 can send or receive standard communication telegrams (message packets).
- In either mode, 512 bytes is the maximum amount of data transferred per data transfer operation
- Data byte order can be swapped to support different device-specific word formats
- Communication activity indications and diagnostic information are available through LEDs and acknowledgment telegrams.
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50°C |
| |
-4 to 122°F |
|
Storage Temperature |
-40 to 85°C |
| |
-40 to 185°F |
| Relative Humidity |
5% to 95% (non-condensing) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
DB-9M RS-232 only |
| |
No hardware handshaking |
Ethernet Port (Ethernet protocol gateways only) |
10Base-T half duplex RJ45 Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports (Serial protocol gateways only) |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor |
| |
Note: The number of serial application ports depends on the module type, and the combination of protocols. |
|
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
| |
3000V DC min. isolation port to ground and port to logic |
|
Shipped with each unit |
Mini-DIN to DB-9M serial cables |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) |
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2
Ordering Information
|
5202-MNET-S3964R4
|
Modbus TCP/IP to Siemens 3964R Protocol Gateway
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.
Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.