Modbus TCP/IP to Hart Analog Gateway
5208-MNET-HART
5228-MNET-HART
Product Description
The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a Modbus TCP/IP network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.
The Modbus TCP/IP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol. The MNET driver supports Client connections as well as Server connections.
The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
Product Applications
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration File
This file contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, the module.
Modbus TCP/IP Protocol Specifications
The Ethernet driver interfaces with a common internal database in the module. This permits the sharing of data across many different protocols and networks.
Modbus TCP/IP Port Specifications
Server
The MNET module supports server functionality using the reserved Modbus TCP/IP service port 502, as well as service port 2000 to support the TCP/IP encapsulated Modbus protocol that is supported by several HMI manufacturers. Services supported in the module permit client applications (i.e., HMI software packages, Quantum processors, etc.) to read from and write to the module's database.
Data in the module's internal database is accessible for read and write operations by any node on the network supporting the MBAP (service port 502) or MNET (service ports 2000/2001) TCP/IP protocols.
There is no configuration of the MNET module required to implement Server functionality other than setting up the network and database parameters in the user configuration file.
|
Modbus TCP/IP Server
|
|
Type
|
Specification
|
|
General
|
The server driver supports connections to Modbus TCP/IP clients supporting Service Port 502 using the standard MBAP protocol, and clients supporting Modbus on Service Port 2000. - Supports up to five (5) independent server connections for Service Port 502
- Supports up to five (5) independent server connections for Service Port 2000
|
|
Configurable Parameters
|
Module IP Address Modbus address offsetting
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
Client
The module supports a client connection on the TCP/IP network to interface with processors (and other server based devices) using a user constructed command list of up to 100 entries.
|
Modbus TCP/IP Client
|
|
Type
|
Specification
|
|
General
|
The client driver supports the active reading and writing of data with Modbus TCP/IP compatible devices.
- One client connection available (connect up to 100 servers/devices with 100 commands)
|
|
Configurable parameters
|
Number of active commands (Up to 100 for client)
Min Command Delay
Response Timeout
Retry Count Command Error Pointer
|
|
Modbus Commands supported
|
1 : Read Output Status
2 : Read Input Status
3 : Read Multiple Data Registers
4 : Read Input Registers
5 : Write Single Bit
6 : Write Single Data Register
15 : Write Multiple Bits 16 : Write Multiple Data Register
|
|
Command List
|
Up to 100 commands on the Client port, each fully configurable for function, Server IP address, Service Port, register to/from addressing and word/bit count
|
|
Status Data
|
Error codes available on an individual command basis.
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
|
General Parameters
|
|
Communication parameters
|
Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
|
|
Configurable Parameters per Channel
|
Auto-Poll Enable, Short / Long Address Retries, Retries After Error Poll Time After Error, Number of Commands, Slave List Error Pointer
|
|
HART Driver
|
|
Command List
|
Up to 100 fully configurable commands per channel
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
|
|
Isolated HART Analog Input Specifications
|
|
Input Range
|
Current: 4 to 20mA with HART
|
|
esolution
|
16bits
|
|
Input Filter
|
First Order Sync: 10 Hz
|
|
Current Input Resistance
|
247.6 ohms +/- 1%
|
|
Open circuit detection time
|
1/2 second maximum
|
|
Over current
|
+/-40mA continuous, maximum
|
|
Common Mode Noise Rejection
|
105dB
|
|
Calibrated Accuracy @ 25°C
|
4 to 20 mA: 0.05% of reading
|
|
Input Isolation Voltage
|
2500 V RMS per UL 1577, transformer isolated
|
|
24V DC Isolation Voltage
|
1500 VDC
|
HART® is a registered trademark of the HART Communication Foundation
Hardware Specifications
|
Specification
|
Description
|
|
Power Supply Input
|
24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals 2.5 mm screwdriver blade
|
|
Current Load
|
1-4 ch: 190 mA max@ 32 VDC max 5-8 ch: 250 mA max@ 32 VDC max
|
|
Operating Temperature
|
-20 to 50°C (-4 to 122°F)
|
|
Storage Temperature
|
-40 to 85°C (-40 to 185°F)
|
|
Relative Humidity
|
5% to 95% (non-condensing)
|
|
Dimensions
|
Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD) Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)
|
|
LED Indicators
|
Power and Module Status
Application Status HART Channel Activity (Green)
|
|
Configuration Serial Port
|
DB-9M RS-232 only No hardware handshaking
|
|
HART Interface
|
Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs) Screw terminals for each channel
|
|
Electrical Isolation
|
1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
|
|
Input Type
|
Current 4-20mA
|
|
Number of Inputs
|
5X08 = 4 Inputs, 5X28 = 8 Inputs
|
|
Resolution
|
16bits
|
|
Input Filter
|
First Order Sync: 10Hz
|
|
Common Mode Rejection
|
105db @ DC
|
|
Over current
|
+/- 40mA continuous, maximum
|
|
Overvoltage Protection
|
All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection
|
|
Accuracy
|
4 to 20 mA: 0.05% of reading @ 25°C
|
|
24VDC loop output power
|
1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power May be used to provide HART loop power
|
|
Shipped with Each Unit
|
Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only) HART Terminal Block connector
|
|
Certifications
|
CE, cCSAus (Class I, Div 2, Groups ABCD), and ATEX (pending)
|
Click here for dimensions diagram
Ordering Information
|
5208 MNET-HART
|
Modbus TCP/IP to HART Analog Gateway (4 chan)
|
|
5228 MNET-HART
|
Modbus TCP/IP to HART Analog Gateway (8 chan)
|
To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.