DF1 Master/Slave to Hart Multidrop Communication Gateway

5127-DFCM-HART

Product Description

The ProLinx DF1 Master/Slave to Hart Multidrop communications gateway (5127-DFCM-HART) creates a powerful connection between devices on a DF1 network and Hart devices. The module is a stand-alone DIN-rail mounted protocol gateway that provides one serial port and 8 Hart channels.

The DF1 (DFCM) protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable, providing a great deal of flexibility.

The HART protocol driver works as a Master on eight individually configurable channels.

Product Applications

The DFCM-HART gateways are the ideal solution for many applications where DF1 connectivity can be used to integrate Hart devices into a system. The DF1 gateway is a powerful module designed with both Master and Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Hart device support, the module provides a very powerful interface to the many Hart devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Functional Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

DF1 Master/Slave Protocol Specifications

The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).

General Parameters (Software Configurable)

Type

Specifications

Communication parameters

Local Station ID: 0 to 254
Baud Rate:110 to 115K baud
Stop Bits: 1
Data Size: 8 bits
Parity:None, Even, Odd
RTS Timing delays:0 to 65535 ms

Error Checking

BCC and CRC

Miscellaneous

  • Full hardware handshaking control, providing radio, smart modem and multi-drop support
  • Floating point data supported

DF1 Master Protocol Specifications

The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.

The DF1 Master functionality supported by the module includes:

DF1 Master Driver

Type

Specifications

DF1 Modes

Full-Duplex - Master (Module generates commands)
Half-Duplex - Polling

DF1 Supported Commands

Basic Command Set

0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write
0x08 Unprotected Write

PLC-5 Command Set (0x0F)

0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x26 Read-Modify-Write (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address)
0x26 Read-Modify-Write (ASCII Address)

SLC Command Set (0x0F)

0xA1 Prot Typed Read w/2 addr fields
0xA2 Prot Typed Read w/3 addr fields
0xA9 Prot Typed Write w/2 addr fields
0xAA Prot Typed Write w/3 addr fields
0xAB Prot Typed Write w/Mask 3 addr fields

Command List

Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.

Polling of Command List

User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

DF1 Slave Protocol Specifications

The ports on the module can be individually configured to support the slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.

The DF1 Slave functionality supported by the module includes:

DF1 Slave Driver

Type

Specifications

DF1 Modes

Full Duplex - Slave (not peer mode)
Half Duplex - Polled

Configurable parameters per slave port

Data Table File Start (File N[x] 0 to 999)
Data Table File Size (1 - 1000 words)
Data Table location in database (0 to 3999)

DF1 Supported Commands

Basic Command Set

0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write
0x08 Unprotected Write

PLC-5 Command Set (0x0F)

0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address)

SLC Command Set (0x0F)

0xA1 Prot Typed Read w/2 addr fields
0xA2 Prot Typed Read w/3 addr fields
0xA9 Prot Typed Write w/2 addr fields
0xAA Prot Typed Write w/3 addr fields

HART Specifications

This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters (Software Configurable)

Type

Specifications

Communication parameters

Number of HART Preambles: 2 to 50
Enable Handheld: Y or N
Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable
Short Address Retries
Long Address Retries
Retries After Error
Poll Time After Error
Number of Commands
Slave List Error Pointer

HART Driver

Type

Specifications

HART Commands supported

Universal Command Set

00 Read Unique Identifier
01 Read Primary Variable
02 Read Current And Percent Of Range
03 Read Dynamic Variables
06 Write Polling Address
11 Read Unique Identifier Associated With Tag
12 Read Message
13 Read Tag Descriptor Date
14 Read PV Sensor Info
15 Read Output Information
16 Read Final Assembly Number
17 Write Message
18 Write Tag Descriptor Date
19 Write Final Assembly Number

Common Practice Command Set

33 Read Transmitter Variables
34 Write Damping Value
35 WriteRange Values
36 SetUpperRange Value
37 SetLowerRange Value
38 Reset Configuration Changed Flag
39 EEprom Control
40 Enter Exit Fixed Current Mode
41 Perform Transmitter Self Test
42 Perform Master Reset
43 Set Pv Zero
44 Write Pv Units
45 Trim Dac Zero
46 Trim Dac Gain
47 Write Transfer Function
48 Read Additional Transmitter Status
49 Write Pv Sensor Serial Number
50 Read Dynamic Variable Assignments
51 Write Dynamic Variable Assignments
52 Set Transmitter Variable Zero
53 Write Transmitter Variable Units
54 Read Transmitter Variable Information
55 Write Transmitter Variable Damping Value
56 Write Transmitter Variable Sensor Serial Number
57 Read Unit Tag Descriptor Date
58 Write Unit Tag Descriptor Date
59 Write Number Of Response Preambles
108 Write Burst Mode Command Number
109 Burst Mode Control
110 Read All Dynamic Variables

Command List

Up to 100 command per channel, each fully configurable for function, slave address, register to/from addressing and word count for Floating Point or Integer Data

Status Data

Error codes returned by the HART protocol available on an individual command basis. In addition, a slave status list is maintained per active channel.

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

Hardware Specifications

Power Supply 24 VDC nominal
  18-32 VDC allowed
  Positive, Negative, GND Terminals
  2.5 mm screwdriver blade

Current Load

500 mA max@ 32 VDC max
Operating Temperature -20 to 50°C
  -4 to 122°F
Storage Temperature -40 to 85°C
  -40 to 185°F
Relative Humidity 5% to 95% (non-condensing)
Dimensions

Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD

LED Indicators

Power and Module Status

  Application Status
  Serial Port Activity LED
  Serial Activity and Error LED Status
Configuration Serial Port DB-9M RS-232 only
  No hardware handshaking
Ethernet Port
(Ethernet protocol gateways only)
10Base-T half duplex RJ45 Connector
  Link and Activity LED indicators
  Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
  Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration
Application Serial Ports (Serial protocol gateways only) RS-232/422/485
  RS232 handshaking configurable
  RS-422/485 DB-9 to Screw Terminal Adaptor
  Note: The number of serial application ports depends on the module type, and the combination of protocols.
Serial Port Isolation 2500V RMS port signal isolation per UL 1577
  3000V DC min. isolation port to ground and port to logic
Shipped with each unit Mini-DIN to DB-9M serial cables
  4 ft RS-232 configuration cable
  2.5mm screwdriver
  CD (docs and Configuration utility)
  RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only)

HART Connector

12 pos screw-terminal plug (J212)

 

Termination Resistor Packet (4 resistors)

HART LED Indicators

CH1-4

Click here for dimensions diagram

Certifications

The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2


Ordering Information

5127-DFCM-HART

DF1 Master/Slave to HART Multi-drop 8 channel

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe/Middle East/Africa
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com

Home : Products : Support : Distributors : Services : News/Events : Contact : ProSoft Tested