EtherNet/IP to HART Multi-drop Communication Gateway
5207-DFNT-HART
Product Description
The ProLinx family EtherNet/IP to HART Multi-drop communications module (5207-DFNT-HART) creates a powerful connection between devices on an EtherNet/IP network and HART Multi-drop devices. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port and four HART Multi-drop channels.
The HART protocol driver works as a Master on four or eight channels (available only on some configurations) per interface card, depending on implementation. Each channel is individually configurable.
Product Applications
The DFNT-HART modules are the ideal solution for the many applications where EtherNet/IP connectivity can be used to integrate HART Multi-drop devices into a system.
The EtherNet/IP gateway is a powerful module designed with both Client and Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the HART Multi-drop device support, the module provides a very powerful interface to the over two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
EtherNet/IP (Explicit Messaging) Compatible Devices
Rockwell Automation equipment that supports EPIC:
-
PLC5/E rev C/N, D/E, E/D
-
SLC5/05 series A, OS503 frn4
-
1785-ENET Series A, rev D
-
Interchange V6.2
-
MicroLogix 1100/1400/ANY via 1761-NET-ENI
-
CompactLogix 1768-L43/L45 via 1768-ENBT
-
CompactLogix 1769-L32E/L35E/ANY
-
CompactLogix L23E
-
RSLinx Gateway V1.7+
-
ControlLogix 1756-ENET/ENBT/EN2T/EN2TR
Functional Specifications
Internal Database
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
Application Data Area
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
Status Data Area
This area is used to store error codes, counters, and port status information for each port.
Configuration Data Area
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
HART Specifications
The HART Master Protocol exists in 4 and 8 channel configurations depending on hardware configuration for the second protocol:
- 4 or 8 HART channels if second protocol is serial
- For other protocols, 4 HART channels
This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.
The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.
|
General Parameters (Software Configurable)
|
|
Type
|
Specifications
|
|
Communication parameters
|
Number of HART Preambles: 2 to 50
Enable Handheld: Y or N Primary Master: Y or N
|
|
Configurable Parameters per Channel
|
Auto-Poll Enable
Short Address Retries
Long Address Retries
Retries After Error
Poll Time After Error
Number of Commands Slave List Error Pointer
|
|
HART Driver
|
|
Type
|
Specifications
|
|
HART Commands supported
|
Universal Command Set
00 Read Unique Identifier
01 Read Primary Variable
02 Read Current And Percent Of Range
03 Read Dynamic Variables
06 Write Polling Address
11 Read Unique Identifier Associated With Tag
12 Read Message
13 Read Tag Descriptor Date
14 Read PV Sensor Info
15 Read Output Information
16 Read Final Assembly Number
17 Write Message
18 Write Tag Descriptor Date 19 Write Final Assembly Number
Common Practice Command Set
33 Read Transmitter Variables
34 Write Damping Value
35 WriteRange Values
36 SetUpperRange Value
37 SetLowerRange Value
38 Reset Configuration Changed Flag
39 EEprom Control
40 Enter Exit Fixed Current Mode
41 Perform Transmitter Self Test
42 Perform Master Reset
43 Set Pv Zero
44 Write Pv Units
45 Trim Dac Zero
46 Trim Dac Gain
47 Write Transfer Function
48 Read Additional Transmitter Status
49 Write Pv Sensor Serial Number
50 Read Dynamic Variable Assignments
51 Write Dynamic Variable Assignments
52 Set Transmitter Variable Zero
53 Write Transmitter Variable Units
54 Read Transmitter Variable Information
55 Write Transmitter Variable Damping Value
56 Write Transmitter Variable Sensor Serial Number
57 Read Unit Tag Descriptor Date
58 Write Unit Tag Descriptor Date
59 Write Number Of Response Preambles
108 Write Burst Mode Command Number
109 Burst Mode Control 110 Read All Dynamic Variables
|
|
Command List
|
Up to 100 command per channel, each fully configurable for function, slave address, register to/from addressing and word count for Floating Point or Integer Data
|
|
Status Data
|
Error codes returned by the HART protocol available on an individual command basis. In addition, a slave status list is maintained per active channel.
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.
|
EtherNet/IP Protocol Specifications
The EtherNet/IP protocol is one of the primary connectivity tools to the different Rockwell Automation platforms. The Explicit Messaging aspect of the protocol (only) has been implemented in the ProLinx units to provide the data transfer link between the ProLinx units and the Rockwell Automation hardware. (Implicit Messaging (I/O communications) is not supported)
|
General Protocol Information
|
|
Messaging
|
PCCC on CIP Explicit Messaging supported
|
|
Compatibility
|
Compatible devices include a wide assortment of other client/server devices such as:
- PLC5/E Rev. C/N, D/E, E/D or later
- SLC5/05 Series A, OS503 frn4 or later
- ControlLogix processor via 1756-ENET
- 1785-ENET Series A, Rev. D
- Interchange (release dependent)
- RSLinx Gateway V1.7 or later
|
|
Miscellaneous
|
125 word read and write data lengths Floating point data supported
|
EtherNet/IP Server Specifications
When in the Server mode, the module accepts commands from one or more clients to read/write data stored in the module's internal registers.
|
EtherNet/IP Server Specifications
|
|
Connections
|
Five (5) independent TCP server sockets permit remote clients to interact with all data contained in the module.
|
|
Data File
|
Data Table File Start - Fixed at N10 Data Table File Size - 100 or 1000 words
|
|
PCCC on CIP
Commands supported
(DF1 commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x00 WordRange Write (ASCII Address) 0x01 WordRange Read (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields 0xAA Prot Typed Write w/ 3 addr fields
|
|
CIP Services Supported
|
0x4C CIP Data Table Read 0x4D CIP Data Table Write
|
EtherNet/IP Client Specifications
When configured in Client mode, the module controls the read/write data transfer between the gateway and other Ethernet/IP devices. When configured in this mode, data transfer can be initiated and executed without any ladder programming being required in the Rockwell Automation hardware.
|
EtherNet/IP Client Specifications
|
|
General
|
One client
|
|
Command List
|
Support for 100 commands, each configurable for command, IP address, register to/from addressing and word/bit count
|
|
Polling of command list
|
User configurable polling of commands, including disabled, continuous and on change of data (write only)
|
|
PCCC on CIP
Commands Supported
(DF1 Commands)
|
Basic Command Set
0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write 0x08 Unprotected Write
PLC-5 Command Set (0x0F)
0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x26 Read-Modify-Write (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address) 0x26 Read-Modify-Write (ASCII Address)
SLC Command Set (0x0F)
0xA1 Prot Typed Read w/ 2 addr fields
0xA2 Prot Typed Read w/ 3 addr fields
0xA9 Prot Typed Write w/ 2 addr fields
0xAA Prot Typed Write w/ 3 addr fields 0xAB Prot Typed Write w/ Mask 3 addr fields
|
|
Status Data
|
Error codes available on an individual command basis.
|
EtherNet/IP (Explicit Messaging) Compatible Devices
List of Rockwell Automation material that support EPIC:
- PLC5/E rev C/N, D/E, E/D
- SLC5/05 series A, OS503 frn4
- 1785-ENET Series A, rev D
- Interchange V6.2
- MicroLogix 1100/1400/ANY via 1761-NET-ENI
- CompactLogix 1768-L43/L45 via 1768-ENBT
- CompactLogix 1769-L32E/L35E/ANY via 1761-NET-ENI
- RSLinx Gateway V1.7+
- ControlLogix 1756-ENET/ENBT/EN2T
ProLinx DFNT Client Counts
The following table lists the number and type of DFNT Clients and Servers available on ProLinx
gateways based on the companion protocol installed on the gateway.
|
ProLinx
Model Number / Part Number
|
Number of Connected DFNT Clients (TCP/IP)
|
Number of Unconnected DFNT Clients (UDP)
|
Number of Connected DFNT Servers ( TCP/IP)
|
|
5201-DFNT-101M
|
2
|
1
|
1
|
|
5201-DFNT-101S
|
2
|
1
|
1
|
|
5201-DFNT-103M
|
1
|
1
|
1
|
|
5201-DFNT-104S
|
2
|
1
|
1
|
|
5201-DFNT-ASCII
|
2
|
1
|
1
|
|
5201-DFNT-BACNET
|
2
|
1
|
1
|
|
5201-DFNT-BSCH
|
2
|
0
|
1
|
|
5201-DFNT-CLVM
|
2
|
0
|
1
|
|
5201-DFNT-DFCM
|
2
|
1
|
1
|
|
5201-DFNT-DH485
|
2
|
1
|
1
|
|
5201-DFNT-DNPM
|
1
|
1
|
1
|
|
5201-DFNT-DNPS
|
2
|
1
|
1
|
|
5201-DFNT-DNPSNET
|
2
|
1
|
1
|
|
5201-DFNT-EGD
|
1
|
1
|
1
|
|
5201-DFNT-GRCM
|
2
|
0
|
1
|
|
5201-DFNT-ISDA
|
2
|
0
|
1
|
|
5201-DFNT-MCM
|
2
|
1
|
1
|
|
5201-DFNT-PNPM
|
2
|
0
|
1
|
|
5201-MNETC-DFNT
|
1
|
1
|
0
|
|
5201-MNET-DFNT
|
1
|
1
|
1
|
|
5202-DFNT-ASCII4
|
2
|
1
|
1
|
|
5202-DFNT-BSCH4
|
2
|
0
|
1
|
|
5202-DFNT-CLVM4
|
2
|
0
|
1
|
|
5202-DFNT-DFCM4
|
1
|
1
|
1
|
|
5202-DFNT-GRCM4
|
2
|
0
|
1
|
|
5202-DFNT-ISDA4
|
2
|
0
|
1
|
|
5202-DFNT-MCM4
|
2
|
1
|
1
|
|
5202-DFNT-PNPM4
|
2
|
0
|
1
|
|
5204-DFNT-PDPM
|
5
|
1
|
1
|
|
5204-DFNT-PDPMV1
|
2
|
1
|
0
|
|
5205-DFNT-PDPS
|
5
|
1
|
1
|
|
5206-DFNT-DEM
|
5
|
1
|
1
|
|
5207-DFNT-HART
|
4
|
1
|
1
|
|
5208-DFNT-HART
|
4
|
1
|
1
|
|
5209-DFNT-CCLINK
|
2
|
1
|
1
|
|
5210-DFNT-RIO
|
5
|
1
|
1
|
|
5228-DFNT-HART(2)
|
4
|
1
|
1
|
|
5303-MBP-DFNT
|
2
|
1
|
1
|
Hardware Specifications
| Power Supply |
24 VDC nominal |
| |
18-32 VDC allowed |
| |
Positive, Negative, GND Terminals |
| |
2.5 mm screwdriver blade |
Current Load
|
500 mA max@ 32 VDC max |
| Operating Temperature |
-20 to 50°C |
| |
-4 to 122°F |
|
Storage Temperature |
-40 to 85°C |
| |
-40 to 185°F |
| Relative Humidity |
5% to 95% (non-condensing) |
| Dimensions |
Standard
5.20H x 2.07W x 4.52D inches
13.2cmH x 5.25cmW x 11.48cmD
Extended
5.20H x 2.73W x 4.52D inches
13.2cmH x 6.934cmW x 11.48cmD |
|
LED Indicators |
Power and Module Status |
| |
Application Status |
| |
Serial Port Activity LED |
| |
Serial Activity and Error LED Status |
| Configuration Serial Port |
DB-9M RS-232 only |
| |
No hardware handshaking |
Ethernet Port (Ethernet protocol gateways only) |
10Base-T half duplex RJ45 Connector |
| |
Link and Activity LED indicators |
| |
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 |
| |
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
|
Application Serial Ports (Serial protocol gateways only) |
RS-232/422/485 |
| |
RS232 handshaking configurable |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor |
| |
Note: The number of serial application ports depends on the module type, and the combination of protocols. |
|
Serial Port Isolation |
2500V RMS port signal isolation per UL 1577 |
| |
3000V DC min. isolation port to ground and port to logic |
|
Shipped with each unit |
Mini-DIN to DB-9M serial cables |
| |
4 ft RS-232 configuration cable |
| |
2.5mm screwdriver |
| |
CD (docs and Configuration utility) |
| |
RS-422/485 DB-9 to Screw Terminal Adaptor for each serial application port (serial protocols only) |
|
HART Connector
|
12 pos screw-terminal plug (J212)
|
|
|
Termination Resistor Packet (4 resistors)
|
|
HART LED Indicators
|
CH1-4
|
Click here for dimensions diagram Certifications
The ProLinx gateway module has the following certifications:
CE
ATEX Cat 3 Zone 2
cULus Haz Loc Class I, Div 2
Ordering Information
|