DF1 Master/Slave to HART Analog Gateway

5108-DFCM-HART

5128-DFCM-HART

Product Description

The HART Analog Input Gateway provides a clean way to integrate HART Analog instruments with existing controller platforms on a DF1 network. The gateway works well for field applications where it can be installed closer to HART instrument, saving on copper cable and installation costs. The gateway also saves valuable rack space for other in-chassis options. The gateways provide extremely fast channel update times (all channels updating simultaneously in 67 ms) making the HART Analog Input Gateway ideal for applications where high speeds and point-to-point connectivity are required. These gateways are available in 4 and 8 Analog input channel options.

The DF1 (DFCM) protocol driver supports Master or Slave implementations of the protocol on each DF1 port. All DF1 ports are individually configurable, providing a great deal of flexibility.

The HART Analog Protocol exists in 4 and 8 channel implementations. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

Product Applications

Configuration
ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files and view module and network diagnostics. PCB is not only a powerful solution for new configuration files, but also allows you to import information from previously installed (known working) configurations to new projects.

Functional Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

DF1 Master/Slave Protocol Specifications

The DF1 Master/Slave Protocol driver provides extensive support for both Master and Slave implementations of the protocol. The serial port on the gateway is user-configurable to support the DF1 protocol (Master or Slave, Error Checking, Baud rate, etc).

General Parameters (Software Configurable)

Type

Specifications

Communication parameters

Local Station ID: 0 to 254
Baud Rate:110 to 115K baud
Stop Bits: 1
Data Size: 8 bits
Parity:None, Even, Odd
RTS Timing delays:0 to 65535 ms

Error Checking

BCC and CRC

Miscellaneous

  • Full hardware handshaking control, providing radio, smart modem and multi-drop support
  • Floating point data supported

DF1 Master Protocol Specifications

The ports on the module can be individually configured as Master ports. When configured in master mode, the DFCM module is capable of reading and writing data to remote DF1 devices.

The DF1 Master functionality supported by the module includes:

DF1 Master Driver

Type

Specifications

DF1 Modes

Full-Duplex - Master (Module generates commands)
Half-Duplex - Polling

DF1 Supported Commands

Basic Command Set

0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write
0x08 Unprotected Write

PLC-5 Command Set (0x0F)

0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x26 Read-Modify-Write (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address)
0x26 Read-Modify-Write (ASCII Address)

SLC Command Set (0x0F)

0xA1 Prot Typed Read w/2 addr fields
0xA2 Prot Typed Read w/3 addr fields
0xA9 Prot Typed Write w/2 addr fields
0xAA Prot Typed Write w/3 addr fields
0xAB Prot Typed Write w/Mask 3 addr fields

Command List

Up to 100 commands per Master port, each fully-configurable for function, slave address, register to/from addressing and word/bit count

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.

Polling of Command List

User-configurable polling of commands, including disabled, continuous, and on change of data (write only)

DF1 Slave Protocol Specifications

The ports on the module can be individually configured to support the slave mode of the DF1 protocol. When in slave mode, the module can accept DF1 commands from a master to read/write data stored in the module's internal registers.

The DF1 Slave functionality supported by the module includes:

DF1 Slave Driver

Type

Specifications

DF1 Modes

Full Duplex - Slave (not peer mode)
Half Duplex - Polled

Configurable parameters per slave port

Data Table File Start (File N[x] 0 to 999)
Data Table File Size (1 - 1000 words)
Data Table location in database (0 to 3999)

DF1 Supported Commands

Basic Command Set

0x00 Protected Write
0x01 Unprotected Read
0x02 Protected Bit Write
0x05 Unprotected Bit Write
0x08 Unprotected Write

PLC-5 Command Set (0x0F)

0x00 WordRange Write (Binary Address)
0x01 WordRange Read (Binary Address)
0x00 WordRange Write (ASCII Address)
0x01 WordRange Read (ASCII Address)

SLC Command Set (0x0F)

0xA1 Prot Typed Read w/2 addr fields
0xA2 Prot Typed Read w/3 addr fields
0xA9 Prot Typed Write w/2 addr fields
0xAA Prot Typed Write w/3 addr fields

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters

Communication parameters

Number of HART Preambles: 2 to 50
Enable Handheld: Y or N
Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable, Short / Long Address Retries, Retries After Error
Poll Time After Error, Number of Commands, Slave List Error Pointer

HART Driver

Command List

Up to 100 fully configurable commands per channel

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

Isolated HART Analog Input Specifications

Input Range

Current: 4 to 20mA with HART

esolution

16bits

Input Filter

First Order Sync: 10 Hz

Current Input Resistance

247.6 ohms +/- 1%

Open circuit detection time

1/2 second maximum

Over current

+/-40mA continuous, maximum

Common Mode Noise Rejection

105dB

Calibrated Accuracy @ 25°C

4 to 20 mA: 0.05% of reading

Input Isolation Voltage

2500 V RMS per UL 1577, transformer isolated

24V DC Isolation Voltage

1500 VDC

HART® is a registered trademark of the HART Communication Foundation

Hardware Specifications

Specification

Description

Power Supply Input

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

1-4 ch: 190 mA max@ 32 VDC max
5-8 ch: 250 mA max@ 32 VDC max

Operating Temperature

-20 to 50°C (-4 to 122°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Relative Humidity

5% to 95% (non-condensing)

Dimensions

Standard: 5.20H x 2.07W x 4.52D in. (13.2cmH x 5.25cmW x 11.48cmD)
Extended: 5.20H x 2.73W x 4.52D in. (13.2cmH x 6.934cmW x 11.48cmD)

LED Indicators

Power and Module Status
Application Status
HART Channel Activity (Green)

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

HART Interface

Four or eight HART Point-to-Point channels (5x08 = 4 inputs; 5x28 = 8 inputs)
Screw terminals for each channel

Electrical Isolation

1500 Vrms at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

Input Type

Current 4-20mA

Number of Inputs

5X08 = 4 Inputs, 5X28 = 8 Inputs

Resolution

16bits

Input Filter

First Order Sync: 10Hz

Common Mode Rejection

105db @ DC

Over current

+/- 40mA continuous, maximum

Overvoltage Protection

All HART Inputs: 90V 3-electrode gas discharge tube, surge arrestor: 30V MOV for voltage protection, 300mA poly switch resettable fuse for over current protection

Accuracy

4 to 20 mA: 0.05% of reading @ 25°C

24VDC loop output power

1 Internal 24VDC supply for each 4 channels. Screw terminals for Isolated 24VDC loop power
May be used to provide HART loop power

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports, serial protocol modules only)
HART Terminal Block connector

Certifications

CE, cCSAus (Class I, Div 2, Groups ABCD), and ATEX (pending)

Click here for dimensions diagram

Ordering Information

5108-DFCM-HART

DF1 Master/Slave to HART Analog Gateway (4 chan)

5128-DFCM-HART

DF1 Master/Slave to HART Analog Gateway (8 chan)

To place an order, please contact your local ProSoft Technology, Inc. distributor. For a list of ProSoft distributors near you, click here.

Distributors:
Place your order by email to orders@prosoft-technology.com:, fax to +1 661-716-5101.

Sales and Support:

Asia Pacific
+603.7724.2080
asiapc@prosoft-technology.com
Europe
+33 (0)5.34.36.87.20
europe@prosoft-technology.com
Latin America
Office: +1 281.298.9109
Mobile: +1-281-830-8946
latinam@prosoft-technology.com
North America
+1 661.716.5100
Fax: +1 661.716.5101
info@prosoft-technology.com