The ProLinx Rockwell Automation Remote I/O Adapter to DNP 3.0 Master Gateway creates a powerful connection between devices on a DNP 3.0 network and a Remote I/O network. This stand-alone DIN-rail mounted protocol gateway provides one serial port and one RIO port.
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The RIO-PDPM modules are the ideal solution for the many applications where Remote I/O connectivity can be used to integrate a PROFIBUS DP slave device into a system. The Remote I/O gateway is a powerful module designed with Slave support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the PROFIBUS DP Master device support, the module provides a very powerful interface to the many PROFIBUS slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The RIO-DNPM modules are the ideal solution for the many applications where DNP 3.0 Master connectivity can be used to integrate Remote I/O serial devices into a system. The DNP Master gateway is a powerful module designed with Server support, enabling easy connection to Rockwell Automation PLCs (CLX, SLC, PLC, CPLX, and similar devices). In combination with the Remote I/O device support, the module provides a very powerful interface to the many Remote I/O devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.
The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.
The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.
The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.
This area is used to store error codes, counters, and port status information for each port.
This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.
Specification | Description |
Power Supply |
24 VDC nominal |
Current Load | 500 mA max @ 32 VDC max |
Operating Temperature | -4° F to 122° F (-20° C to 50° C) |
Storage Temperature | -40° F to 185° F (-40° C to 85° C) |
Relative Humidity | 5% to 95% (with no condensation ) |
Dimensions |
Standard: |
LED Indicators |
Power and Module Status |
Configuration Serial Port |
DB-9M RS-232 only |
Ethernet Port (Ethernet modules only) |
10Base-T half duplex RJ45 Connector |
Application Ports |
Modbus Plus Connector |
Serial Port Isolation |
2500 V RMS port signal isolation per UL 1577 |
Shipped with Each Unit |
Mini-DIN to DB-9M serial cables |
ProSoft Configuration Builder (PCB) | ||
RIO-DNPM Datasheet | 67.69 kB | Last Modified 05/10/2010 |
DNPM Driver Manual | 1.22 MB | Last Modified 12/14/2020 |
RIO Protocol Manual | 571.18 kB | Last Modified 02/10/2012 |
Prlxrio Sample Ladder | 257.05 kB | Last Modified 09/03/2008 |
The RIO interface is an adapter (slave) which can be connected to a scanner (master) that controls the data transfer. The module also supports limited high speed data transfer via the Input and Output images.
The RIO interface is an adapter (slave) and is connected to a scanner (master) that controls the data transfer. For example, the master/slave relationship can be accomplished using the RIO module (adapter/slave unit) with a Rockwell Automation PLC5 (scanner/master unit). Ladder logic must be programmed into a PLC to perform BTR/BTW commands to receive and transmit data between the module and the PLC. The module also supports limited high speed data transfer via the input and output images.
Software Configurable Parameters |
|
Rack Number Addressing | 0 to 63 |
Rack Size | ¼-rack, ½-rack, ¾-rack and full rack |
Starting Group | 0,2,4,6 |
Last Rack | Yes or No |
Baud Rate | 57.6K, 115K, 230K |
Functional Specifications |
|
Supports block-transfers of data with scanner |
|
Supports I/O data movement. Amount determined by rack size configuration |
|
BTW Command - up to 64 words |
|
BTR Command - up to 63 words |
|
Physical Connection |
|
Remote I/O connector | Standard 3-screw termination connector |
The DNP 3.0 Master protocol driver supports Master implementations of the protocol on one port. This port is fully configurable.
The DNP 3.0 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the DNP 3.0 protocol (Master, Baud Rate, etc).
General Parameters |
|
Internal Database | Binary Inputs: 0 to 500 word count Analog Inputs: 0 to 500 points Counters: 0 to 250 points Binary Outputs: 0 to 500 word count Analog Outputs: 0 to 500 points |
DNP Mode | DNP 3.0 Master - Level 2 |
DNP Object Support | DNPM Driver Manual contains full Object Definition documentation |
DNP Master |
|
Node address | 0 to 65534 (software selectable) |
Slave count | Up to 40 slave devices |
Command count | Up to 300 user defined commands to interface with remote slave devices |
Ex Certificate (ATEX Directive) | 114.27 kB | Last Modified 03/13/2019 |
CB Safety | 35.78 kB | Last Modified 08/27/2012 |
CE Mark | 92.32 kB | Last Modified 03/07/2019 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1.92 MB | Last Modified 07/10/2020 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1.92 MB | Last Modified 07/10/2020 |
UL/cUL; Class 1, Div 2 | 1.08 MB | Last Modified 03/31/2020 |
UL/cUL; Class 1, Div 2 (Canada) | 1.10 MB | Last Modified 07/02/2013 |