The Industrial Frequency Hopping 900 MHz Ethernet provides powerful and secure wireless Ethernet communications and is well suited for demanding, long-range (up to 30+ miles) SCADA and other Ethernet applications in tough environments. Operating in the license-free 900 MHz band, the RadioLinx Industrial Frequency Hopping 900 MHz Ethernet penetrates foliage and walls / ceilings better than higher frequency radios. The RLX-IFH9E is user configurable as a master, repeater and remote radio and employs the 128 bit AES encryption algorithm approved by the United States government for top secret information.

Industrial Frequency Hopping 900 MHz Ethernet radios are quickly and easily configured using the included, graphical ControlScape software. An OPC server software is also included and allows users to monitor radio network health with any OPC client based HMI software.

Architectures

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Features and Benefits

High Speed 900 MHz Ethernet

  • 1.1 Mbps RF data rate at up to 30+ miles
  • Low latency mode supports up to 300 packets per second
  • Longer wavelength of the unlicensed 900 MHz for superior wireless signal propagation vs. higher frequency

Rugged and Powerful

  • Up to 1 watt transmit power for long distance
  • Programmable frequencies to co-exist with other wireless networks or avoid interference
  • Metal enclosure, industrial operating temperatures, vibration and shock resistant
  • Certification Pending for use in hazardous locations (CSA/UL Class I Div 2)

Strong Data and Network Security

  • 128 bit AES Encryption with TKIP
  • Proprietary FHSS not detected by 802.11 wireless
  • Easy to Configure and Monitor
  • Graphical representation of network for configuration and diagnostics
  • Advanced diagnostics including VSWR, temperature, and signal quality
  • Included OPC Server for HMI-based RF network diagnostics

Backed by ProSoft Technology

  • Industrial data communications experts who understand your protocols, devices, and applications
  • Indoor/outdoor radio network design assistance – accessory selection, path studies, and site survey
  • Three year standard warranty

Specifications

Frequency

902-928 MHz

Protocols

All Standard IEEE 802.3 protocols

Security

128 bit AES encryption

Network Topology

Point-to-point, point-to-multipoint, Store and forward repeater

Error Detection

32 bit CRC, ARQ (Automatic Resend Query)

Radio Type

Frequency Hopping Spread Spectrum

Transmit Power

(Programmable)

100 mW to 1 W (Programmable)

20 dBm to30 dBm (Programmable)

Channel data Rates

1.1 Mbps or 345 kbps (Programmable)

Receiver Sensitivity

1.1 Mbps: -98 dBm @ 10-6 BER 345 kbps: -106 dBm @ 10-6 BER

Outdoor Ranger

30+ miles pt-pt with high gain directional antennas and RF line-of-sight

Network Specifications

IP Assignment

Static, DHCP

VLAN

Supported

Network Time Protocol

Supported

Quality of Service

Supported

Security

AES-128 bit Encryption
Radius Authentication

Management Specifications

Web

HTTP, HTTPS, SSH

SNMP

SNMP v1, v2, v3

OPC

OPC Server Available

Spectrum Analyzer

Supported via Web

Windows Utility

RadioLinx ControlScape

Other

Console, Telnet

Hardware

Enclosure

Extruded aluminum with DIN and panel mount

Size

117 x 112 x 41 mm (W x H x D)
4.6 x 4.4 x 1.6 inches

Vibration

IEC 60068 2-6 (20g, 3-Axis)

Shock

IEC 60068 2-27 (5g, 10Hz to 150Hz)

Ethernet Ports

One 10/100 Base-T connector, shielded RJ45

IEEE 802.3, 802.3u, 802.3x

Serial Data Port

RS-232, DB9 / RS-422 and RS-485

300 bps to 230 kbps Supports serial to serial tunneling and
serial TCP/UDP encapsulation.

Antenna Ports

(1) RP-SMA connector

Weight

1.0 lbs (454 g)

Environmental

Operating Temperature

-40° F to 149°F(-40° C to +65° C)

Humidity

Up to 100% RH, with no condensation

External Power

9Vdc to 30Vdc

Power Consumption

12 W peak

Downloads

ControlScape User’s Manual 1.75 MB Last Modified 02/21/2013
ProSoft Wireless Designer (PSW-PWD) Datasheet 169.63 kB Last Modified 02/21/2013
RLX-IFHxE Overall Dimension Drawings 105.18 kB Last Modified 06/13/2014
ProSoft Wireless Designer User Manual 1.32 MB Last Modified 02/22/2013
SNMP MIB file 53.65 kB Last Modified 02/22/2013
RLX-IFH9E Datasheet 338.17 kB Last Modified 09/06/2013
ControlScape Datasheet 1.17 MB Last Modified 02/01/2018
RadioLinx OPC Server Datasheet 282.21 kB Last Modified 07/10/2015
RLX-IFHE User Manual 1.72 MB Last Modified 11/19/2013
RadioLinx OPC Server version 1.3.1 (XP) 1.10 MB Last Modified 02/21/2013
ProSoft Wireless Designer (PSW-PWD) version 4.5.013 6.00 MB Last Modified 05/30/2014
ControlScape FH v6.00.041 3.53 MB Last Modified 05/06/2014
RLX-IFH9E firmware v2011 1.11 MB Last Modified 02/21/2013

Videos

 

Certifications

Australian C-Tick Mark 216.87 kB Last Modified 12/17/2013
Ex Certificate (ATEX Directive) 106.11 kB Last Modified 11/11/2013
CB Safety 32.95 kB Last Modified 08/27/2012
GOST-R Declaration of Conformity 6.68 MB Last Modified 12/18/2012
Country Approval - Brazil 99.34 kB Last Modified 09/12/2012
Country Approval - Brazil 677.10 kB Last Modified 09/12/2012
Country Approval - New Zealand 92.43 kB Last Modified 09/12/2012