My RSSI values do not seem to be accurate beyond a -60dBM signal in my RLX-IFH9E/RLXIFH24E radio. Why?
Due to the design and physical limitations of the RLX-IFH9E and RLX-IFH24E radios, any RSSI values reported that are greater than -60dBm is not accurate. These values cannot be compared to provide a meaningful status of the signal level.
For example, an RSSI reported as -39dBm at one time and -39dBm at another time from the same radio does not mean the signal level is the same. In addition, an RSSI reported as -40dbm is not necessarily a better signal than one reported as -50dbm.
Values above -60dBm will be reported as Max. Values -60dBm and below down to the threshold of operation (about -100dBm) are accurate to within a few dB.
As of July 27, 2010, the latest version is 3.21/1/102. It is planned to address this issue in a future release of ControlScape.?xml:namespace>
?xml:namespace>
Article ID: 445
Created On: Wed, Jul 28, 2010 at 5:49 AM
Last Updated On: Thu, Aug 20, 2015 at 7:57 PM
Authored by: Administrator