Examples:
Client-0 enable Command bits are in N50:21, MSB xxxx xxxx xxxx xxxx LSB.
Client-1 enable Command bits are in N50:22, -//-
Client-29 enable Command bits are in N50:50, -//-
Most users will find it helpful to view this with the radix set to binary.
After manipulating these bits, triggering block 6000 the command enable data to the module. B3:0/4 would trigger this in our sample logic.
Article ID: 528
Created On: Wed, Sep 24, 2014 at 8:34 PM
Last Updated On: Wed, Sep 24, 2014 at 8:35 PM
Authored by: Administrator
Online URL: https://www.prosoft-technology.com/kb/article.php?id=528