<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Rockwell In-chassis  - ControlLogix  - MVI56 Series  </title>
<link>https://www.prosoft-technology.com/kb/category.php?id=10</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB Knowledge Base Script (http://www.knowledgebase-script.com)</description>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=58</guid>
										<title>Why do I have a yellow question mark in the RSWho window or in RSNetworx for my MVI56 Series module?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=58</link>
										<description><![CDATA[If you have a yellow question mark in RSLinx&#039;s RSWho window, or in the RSNetworx window it is usually due to not having the EDS file registered for the MVI56 Series modules.&nbsp;     ]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=6</guid>
										<title>Debug port connection parameters for Prosoft modules and gateways</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=6</link>
										<description><![CDATA[Connect PC to module&#039;s debug / configuration port using a null-modem cable        Start Hyperterminal, Putty or other comm program and use the following settings:                  bits per second: 57,600           data bits: 8           parity:...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=69</guid>
										<title>Can the MVI56-xx modules be placed in a remote rack?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=69</link>
										<description><![CDATA[Generally, yes. When using ControlNet to access the remote chassis, however, I/O bandwidth limitation may become an issue.          Because the MVI56 modules requires 250 words of inputs, and 248 words of output, the ControlNet bandwidth may not be...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=335</guid>
										<title>I have an In-Chassis module, and am seeing a type mismatch shown in the module properties. What is the issue?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=335</link>
										<description><![CDATA[The type mismatch error is always shown since the ProSoft In-Chassis modules do not support the additional functionality required to respond to this inquiry from the processor.&nbsp; This field does not reflect the status of the ProSoft In-Chassis...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=225</guid>
										<title>&quot;Invalid Input Size&quot; when adding an Prosoft module to RSLogix 5000</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=225</link>
										<description><![CDATA[Confirm that the Comm Format parameter in the modules I/O configuration is set to Data - INT. The default setting for this parameter in RSLogix5000 is Data - DINT. This setting will generate the error message mentioned above.       If the incorrect...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=339</guid>
										<title>What is the heat dissapation for MVI56, MVI56E, MVI69, MVI46 and MVI71 modules?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=339</link>
										<description><![CDATA[The heat dissipation for MVI56, MVI56E, MVI69, MVI46 and MVI71modules is as follows: The power ratings label states that the maximum current drawn from the ControlLogix backplane is 800 ma at 5.1 VDC, 4.08 watts.  If you want to convert this to BTU...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=193</guid>
										<title>What RSLogix 5000 function will indicate whether a Prosoft module is present and functioning in the ControlLogix chassis?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=193</link>
										<description><![CDATA[The GSV (get system value) instruction in RSLogix 5000 can retrieve the status of the communication or I/O modules.&nbsp;     The required parameters for GSV are:     class name   module instance name   module name in the I/O configuration  ...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=266</guid>
										<title>The BATT LED on my ProSoft MVI module is RED.  How can I fix this problem?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=266</link>
										<description><![CDATA[The battery is integral, rechargeable, and soldered to the main board of the module. The on-board battery is not user-serviceable.    The purpose of the battery on the MVI module is to maintain the BIOS settings which are checked during the boot up...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=348</guid>
										<title>Can the MVI56-WA-EIP be used to acquire I/O data from a ControlLogix CPU from a remote rack?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=348</link>
										<description><![CDATA[The MVI56-WA-EIP must be installed in a chassis that also has a ControlLogix processor installed.  It will not function in a chassis that is loaded only with I/O modules. Thus you can use two MVI56-WA-EIP modules to move data between two processors. ...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=342</guid>
										<title>What is the backplane current draw for MVI56, MVI56E, MVI69, MVI46 and MVI71  modules?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=342</link>
										<description><![CDATA[The backplane current draw for modules in these series is 800mA at 5.1VDC. Additionally, MVI69 modules are required to be within two slots of a power supply on the 1769 bus.      ]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=604</guid>
										<title>What are Optional AOIs and do I need them?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=604</link>
										<description><![CDATA[Optional AOIs, are, as their name suggests, Add-On Instructions which are not necessary for the operation of their corresponding card.  For most applications, they are completely unnecessary, as the only features they provide are the ability to...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=412</guid>
										<title>I upgraded my RSLogix5000 software from an older version to Version 16 and now the clock in my MVI56 module does not seem to show the correct time.  Why not?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=412</link>
										<description><![CDATA[When Rockwell Automation released Version 16 (and later) revisions of RSLogix5000 programming software for ControlLogix systems, they had to change the starting point of the timebase for the processor&#039;s internal clock and added some new features...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=444</guid>
										<title>When saving a project including a ControlNet network in RSLogix5000 v18, a warning message appears - &quot;Warning: Failed to create new device in ControlNet project file. Generic module cannot be created.&quot;  What does this mean?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=444</link>
										<description><![CDATA[      Using the following configuration:                ·&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; - RSLogix 5000 Version 18              ·&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; - A ControlNet Network is implemented in the project....]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=450</guid>
										<title>My ControlNet network shows a maximum usage value of 99.61% when an MVI56-XXX or MVI56E-XXX is in the rack, why is this?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=450</link>
										<description><![CDATA[99.61% represents the allowable ControlNet bandwidth. The bandwidth rule is that each scheduled node gets 1 and only 1 opportunity to talk during the scheduled portion of a NUT (Network Update Time). The maximum amount of data that any node can...]]></description>

									</item>