<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB Knowledge Base Script (http://www.knowledgebase-script.com)</description>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=322</guid>
										<title>How do I do a Remote Display Connection with the AppSrvCE?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=322</link>
										<description><![CDATA[To be able to have a remote display connection with the AppSrvCE you need to install the Microsoft Remote Desktop utility that you can download for free from the Microsoft Web Site.  Run the Microsoft Remote Desktop from the menu Start ->  Remote...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=323</guid>
										<title>I&#39m not able to create more than 7 interfaces in my EZStudio project, how can I add more interfaces?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=323</link>
										<description><![CDATA[In versions older than 7.07.0015 of the EZStudio Runtime is not possible to add more than 7 interfaces in an EZStudio Project. There are two ways to overcome this, request to the support department for an upgraded version of the EZRuntime or replace...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=341</guid>
										<title>How does one autostart an application in the appsrvce?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=341</link>
										<description><![CDATA[If one is using our EZ Runtime in conjunction with the EZ Dev Studio to develop real-time data aquisition or historical data aquisition and control applications then you may simply add an entry for the application in the Startup file in the...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=321</guid>
										<title>How do I setup the IP Address in an AppSrvCE?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=321</link>
										<description><![CDATA[If you connect a monitor, keyboard and mouse, the IP Address of an AppSrvCE can be changed the same way the IP is changed in a windows PC, going to the Control Panel -> Network Properties. Tipically when an AppSrvCE is installed is not easy to...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=320</guid>
										<title>What are the default IP Addresses on an AppSrvCE unit?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=320</link>
										<description><![CDATA[The factory default configuration of the AppSrvCE Ethernet Ports is as Follows:  Left Port: IP = 192.168.0.1 NetMask = 255.255.255.0   Right Port: IP = Is obtained using DHCP  The easiest way to connect to an AppServer is to connect using the left...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=263</guid>
										<title>How do I change the video display resolution in the AppSrv?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=263</link>
										<description><![CDATA[There is no configuration utility  provided to change the video display resolution. The resolution can be  set by changing the following values in the registry:       hkey_local_machinesoftwaregeoderesolution     ...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=349</guid>
										<title>What can I do to troubleshoot connection problems between Echo Historian and OPC/SLS servers on the PC56/PC56CE/7000AppSrvCE platforms?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=349</link>
										<description><![CDATA[DCOM configuration issues are the most likely causes for connectivity issues from/to the Echo Historian &amp; OPC/SLS servers offered on the PC56/PC56CE/7000 AppSrvCE solutions.  This relates to how Windows network clients validate each others...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=388</guid>
										<title>How do I get AppServCE applications to Auto-Start on power-up?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=388</link>
										<description><![CDATA[On the AppSrvCE you can create a registry value to start a program when the module starts up. In the registry editor (regedit), under &#39HKEY_LOCAL_MACHINESOFTWAREOnline DevelopmentLaunchIt&#39, create a new STRING value, give it any name you like...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=364</guid>
										<title>Every attempt to download an EZ-Studio project to the AppServ module results in an &quot;echoxmlcfg&quot; failure.  How do I fix this?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=364</link>
										<description><![CDATA[Running the TEMU utility in the /DiskOnChip area of the appsrv&#39s filesystem resolves this.]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=385</guid>
										<title>I&#39m developing applications for the AppServ CE and need to know, how do I get applications to auto-start on power-up?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=385</link>
										<description><![CDATA[On the AppSrvCE you can create a registry value to start a program when the module starts up. In the registry editor (regedit), under &#39HKEY_LOCAL_MACHINESOFTWAREOnline DevelopmentLaunchIt&#39, create a new STRING value, give it any name you like...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=373</guid>
										<title>I get an &quot;echoxmlcfg failure&quot; message whenever I try to download an EZ-Studio project to my ProSoft 7000 Historian.  How do I fix this?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=373</link>
										<description><![CDATA[Running the TEMU.exe utility in the /DiskOnChip area of the appsrv&#039;s file system resolves this.  If you are using OPC, then Register OPC Components checkbox should be checked.  The utility will walk you through the maze of unlocking the registry...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=437</guid>
										<title>How can I use fault code 0x00000035 (PWR_DWN_5V_LOSS Power supply is below 5v. Shutdown is eminent) or any other fault code(s) to trigger a shutdown on AppSrv module?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=437</link>
										<description><![CDATA[ When AppSrv actually sees and responds to the corresponding signal from the operating system, shutdown is truly imminent and there may not be adequate time remaining to perform an elegant shutdown so the recommendation is not to use the "0035" ...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=502</guid>
										<title>Why is COM port 1 not available on the AppSrvCE unit?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=502</link>
										<description><![CDATA[The latest AppSrvCE platform, v1.23, includes ELO USB and serial  touch screen drivers.&nbsp; COM1 is allocated by the touch screen serial  driver, whether or not a serial touch screen is actually present.&nbsp; As a  result COM1 is not available to...]]></description>
