<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=109</guid>
										<title>I am unable to view the Debug Menu on my MVI71-DNP module.</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=109</link>
										<description><![CDATA[The MVI71-DNP User Guide states that you should configure your terminal emulation software to 57,600 baud, 8 data bits, no parity, 1 stop bit, no hardware handshaking. In MVI71-DNP configuration, there is a parameter that sets the baud rate for the...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=306</guid>
										<title>How do I deal with an unsigned integer in an SLC, PLC5, or MicroLogix processor?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=306</link>
										<description><![CDATA[Scenario: A device that uses an INT value to represent a range of 0 to 65535, but in the processor the INT tag has a range of -32768 to 32767.    Since the A/B processor does not have an unsigned Integer data type, you will need to convert this value...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=6</guid>
										<title>Debug port connection parameters for Prosoft modules and gateways</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=6</link>
										<description><![CDATA[Connect PC to module&#039;s debug / configuration port using a null-modem cable        Start Hyperterminal, Putty or other comm program and use the following settings:                  bits per second: 57,600           data bits: 8           parity:...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=184</guid>
										<title>What is the difference between the 3100-MCM and the MVI71-MCM</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=184</link>
										<description><![CDATA[ The MVI71-MCM is the latest Modbus module for the Allen-BradleyPLC5 platform. The MVI71-MCM provides a debug port which allows the user to view module configuration and status. The MVI71-MCM provides a built-in data analyzer for troubleshooting...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=209</guid>
										<title>When the MVI71-MCM is connected using Side-Connect, can a Modbus Master device read and write to the same Modbus address in the module?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=209</link>
										<description><![CDATA[Yes, a Modbus master can read and write to the same address in the MVI71-MCM module when side-connect is used.  In the configuration file, the read start and write start values should both be set to the same value (e.g. read start = 0, write start =...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=477</guid>
										<title>IEC-60870-5-104 Server Tutorial</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=477</link>
										<description><![CDATA[The following document outlines the ProSoft implementation of the IEC-60870-5-104 Server communication module as pertains to all -104S products.&nbsp;]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=426</guid>
										<title>Do you have an in-rack Ethernet I/P solution for a PLC-2 processor?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=426</link>
										<description><![CDATA[Yes, the MVI71-DFNT can work in a 1771 chassis with a PLC-2 processor.  Along with the MVI71-DFNT sample ladder, you will need to use the following settings in the PLC-2 programming software:  *The Lengths of the BTW and BTR instructions should be...]]></description>

									</item>