<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Protocols  - PROFIBUS  </title>
<link>https://www.prosoft-technology.com/kb/category.php?id=22</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB Knowledge Base Script (http://www.knowledgebase-script.com)</description>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=85</guid>
										<title>SYCON registration number</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=85</link>
										<description><![CDATA[Registration number : F70FF09BF806       Related Keywords: Sycon software all PDPM ProLinx modules (pdpm - profibus dp master protocol) ]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=121</guid>
										<title>Does ProSoft or ProLinx support Profibus PA?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=121</link>
										<description><![CDATA[By itself the module does not support PROFIBUS PA. However, when used with a PROFIBUS DP/PA coupler, it is possible to communicate with the ProLinx module via PROFIBUS PA.     Related Keywords: PROFIBUS PA DP PDPS PDPM]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=328</guid>
										<title>What is Profibus?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=328</link>
										<description><![CDATA[Please click on the attachment&nbsp;for a tech note on this protocol.]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=129</guid>
										<title>How do I setup my 3170-PDP in Step 7 software?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=129</link>
										<description><![CDATA[Make sure to drop the "3170-PDP 1.2 status" information into the first slot, then each of your I/O modules after that. Any unused slots must have a "flex I/O empty slot" defined in the configuration for that slot setup. ]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=264</guid>
										<title>How to resolve an issue where Siemens Step 7 software displays a message indicating that the ProSoft GSD file cannot be interpreted.</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=264</link>
										<description><![CDATA[PROFIBUS DP GSD file names should be limited to eight characters.File names longer than eight characters will cause this error. Delete the excess characters in the file name so that the file name contains no more than eight characters before the .gsd...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=367</guid>
										<title>I need to set up a ProSoft PROFIBUS Master to talk to a Siemens S7-300 series CPU that is set up as a PROFIBUS Slave.  How do I do that?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=367</link>
										<description><![CDATA[The attached file shows how to set up a S7-315 CPU to be a PROFIBUS DP Slave to a ProSoft MVI56-PDPMV1 PROFIBUS Master and was written for that specific application.Â  However, many of the setup steps apply to other S7 configurations and other...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=296</guid>
										<title>How can I monitor module and slave status with the MVI56-PDPV1 and other PDPMV1 PROFIBUS master modules?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=296</link>
										<description><![CDATA[The PDPMV1 operating state is stored in the MVIxxPDPMV1.Status.Fieldbus.FB_op_state tag:        &nbsp;00 = Offline     &nbsp;40 = Stop     &nbsp;80 = Clear     &nbsp;C0 = Operate         To determine slave status, the MVIxxPDPMV1.Status.Fieldbus...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=393</guid>
										<title>I have a PROFIBUS DP network with ProSoft PROFIBUS DP Master solution that appears to be operating normally (no bus faults, slaves report &quot;OK&quot;), but I am unable to control my devices.  What</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=393</link>
										<description><![CDATA[Many things can result in these symptoms.&nbsp; One of the most common causes is that&nbsp;not all&nbsp;slave manufacturers&nbsp;use a standard byte order.&nbsp; It is very possible that when you think you&#039;re sending a value of "1" to a slave&...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=377</guid>
										<title>I am trying to download my PROFIBUS PDPMV1 Master/Slave configuration from the ProSoft Configuration Builder (PCB) &quot;PROFIBUS - PDPMV1&quot; Online-Download Configuration menu option; and it is lo</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=377</link>
										<description><![CDATA[Please do not use the "Online - Download Configuration" menu option from inside the PCB "PROFIBUS - PDPMV1" configuration window.&nbsp; If you do this, it will lock up PCB, requiring you to shut it down and restart it to clear the error.  Instead,...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=376</guid>
										<title>Can a ProSoft PROFIBUS DP v1 Master solution also be configured as a Slave to another Master?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=376</link>
										<description><![CDATA[Sorry; but this is not possible.&nbsp; However, a ProSoft PROFIBUS DP v1 Master can be configured to pass data to and from another PROFIBUS DP Master by using a third-party DP-to-DP coupler.]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=375</guid>
										<title>Can a ProSoft PROFIBUS DP v1 Master solution communicate directly with other PROFIBUS DP v1 Masters?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=375</link>
										<description><![CDATA[Not all PROFIBUS DP v1 Master devices support Master to Master or&nbsp;"peer-to peer"&nbsp;messaging, as some do.&nbsp; ProSoft PROFIBUS DP v1 Master solutions (those with -PDPMV1 in their part numbers) do not have peer-to-peer support built-in.&nbsp...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=454</guid>
										<title>My Profibus Master (PDPMV1) card is not communicating and will not go into RUN mode but does not show an error in the ProSoft Configuration Builder software, why?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=454</link>
										<description><![CDATA[Due to GSD file errors or&nbsp;device configuration&nbsp;errrors&nbsp;the module&nbsp;may not be able to go into RUN mode.&nbsp; However&nbsp;depending on the type of error (invalid GSD file or exceeding parameter data configuration) the ProSoft...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=402</guid>
										<title>I can't get my ProSoft PROFIBUS DP V1 Master to talk to all of the Slave Nodes on my PROFIBUS network.  What might the problem be?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=402</link>
										<description><![CDATA[The question has several possible answers.&nbsp; Most of them are obvious to anyone familiar with PROFIBUS networks, so we won&#039;t mention them all here.  However, there is one remote possibility that has been known to cause problems in the past...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=476</guid>
										<title>Will the PS69-DPM work with a Siemens 157-xxxxx-0XA0 DP/PA coupler at the baud rate 45.45 Kbit/s?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=476</link>
										<description><![CDATA[          The PS69-DPM does not communicate natively at 45.45 baud.    To communicate through this DP/PA coupler you will need the Siemens “Simatic DP Link”.]]></description>

									</item>

</channel>

</rss>