										<title>What is the purpose of the deadband parameter in the DNP module?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=130</link>
										<description><![CDATA[The deadband parameter sets how event data is generated by your module as a DNP slave device. Take for instance the following configuration values:  AI Deadband : 1000 #0-32767 analog deadband value for events AI Class : 3 #default class for analog...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=133</guid>
										<title>Can there be multiple Master devices on a DNP 3.0 network?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=133</link>
										<description><![CDATA[At this time, our InRAx line of DNP3 serial communications solutions offer 2 DNP serial ports.  One will always be available as a DNP slave to provide data to a DNP serial master system.  The other port may be used as a secondary, redundant DNP slave...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=183</guid>
										<title>Does the ProSoft DNP driver support 32 bit Analog Inputs/Outputs?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=183</link>
										<description><![CDATA[Only the MVI56E-DNPNET supports 32 bit analogs, all other modules and gateways return only the low 16 bits.   However 32 bit counters and floats are supported by most of our DNP3 products.]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=587</guid>
										<title>CROB functions in serial DNP modules</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=587</link>
										<description><![CDATA[Example of using a conditional CROB to control BO 3 in slave 2 to using "Latch on" and Latch off" commands.    Node address (of the slave) is 2. Object 12 Variation 1 Function 5 (Direct Operate) Device Address (point index) in this slave is 3 Point...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=550</guid>
										<title>Shaded Areas in the Subset Definitions</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=550</link>
										<description><![CDATA[What do the shaded areas in the subset definitions indicate?  - Objects that we support that are not required within the Level II specification are shaded.  Refer to the associated notes to determine our response to the message.]]></description>
