<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Rockwell In-chassis  - CompactLogix  - MVI69 Series  </title>
<link>https://www.prosoft-technology.com/kb/category.php?id=6</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB Knowledge Base Script (http://www.knowledgebase-script.com)</description>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=540</guid>
										<title>Do ProSoft CompactLogix modules work with the new CompactLogix processors?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=540</link>
										<description><![CDATA[The requirements for Prosoft&#039;s CompactLogix InRAx modules are:  * 1769 I/O bus * 450-800ma @5v from the bus, depending on the MVI module * Placement within 2-4 slots of a CompactLogix power supply, depending on the MVI module  The power and...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=6</guid>
										<title>Debug port connection parameters for Prosoft modules and gateways</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=6</link>
										<description><![CDATA[Connect PC to module&#039;s debug / configuration port using a null-modem cable        Start Hyperterminal, Putty or other comm program and use the following settings:                  bits per second: 57,600           data bits: 8           parity:...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=335</guid>
										<title>I have an In-Chassis module, and am seeing a type mismatch shown in the module properties. What is the issue?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=335</link>
										<description><![CDATA[The type mismatch error is always shown since the ProSoft In-Chassis modules do not support the additional functionality required to respond to this inquiry from the processor.&nbsp; This field does not reflect the status of the ProSoft In-Chassis...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=211</guid>
										<title>RSLogix 500 sample for MVI69-xxx faults MicroLogix processor</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=211</link>
										<description><![CDATA[I/O mismatch the first versions of our MVI69-XXX sample for MicroLogix processors had the wrong vendor ID code defined under the I/O configuration.   Within the RSLogix 500 program change the vendor ID code from 22 to the correct vendor ID code of...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=172</guid>
										<title>Is the MVI69 series of ProSoft modules compatible with the MicroLogix1500 processor?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=172</link>
										<description><![CDATA[If the controller is an LRP with serial ports and has firmware version 6.0 or greater, then yes, the MVI69 is compatible with the system.     Related Keywords: MVI69 CompactLogix MicroLogix ]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=477</guid>
										<title>IEC-60870-5-104 Server Tutorial</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=477</link>
										<description><![CDATA[The following document outlines the ProSoft implementation of the IEC-60870-5-104 Server communication module as pertains to all -104S products.&nbsp;]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=415</guid>
										<title>Will ProSoft MVI69-xxxx solutions work with the new Allen-Bradley CompactLogix L23 series of processors?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=415</link>
										<description><![CDATA[ProSoft&nbsp; MVI69 solutions require a minimum of 800mA of 5vdc current be available from the backplane of any CompactLogix system in which they are installed.  Within the 1769-L23x processor family, our MVI69-xxx modules will work with some but not...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=438</guid>
										<title>When using an MVI69-xxx or PS69-xxx module, why does a L43/L45 CompactLogix processor fault immediately after a download or after a power cycle?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=438</link>
										<description><![CDATA[A firmware anomaly has been identified in version 17 for the CompactLogix 1768-L43 and L45 processor that will&nbsp;not work properly when using any Prosoft MVI69 or PS69 communication modules.  FRN 18 will correct the issue.    Work around&#039;s...]]></description>

									</item>
<item>
										<guid>https://www.prosoft-technology.com/kb/article.php?id=405</guid>
										<title>My MVI69 module is not working.  What might be wrong?</title>
										<link>https://www.prosoft-technology.com/kb/article.php?id=405</link>
										<description><![CDATA[There are many things that may prevent a MVI69 module from working properly.&nbsp; Here is a list of the most commonly overlooked items that can prevent it from working as expected:    1.&nbsp; The Prosoft provided sample ladder logic OR Add-On...]]></description>

									</item>

</channel>

</rss>