ReadMe.txt - README FILE FOR MVI69E-AFC SAMPLE LADDER PROGRAMS
Ver#         Date     
-----     ----------  
v1.3      2020-05-27     
v1.4	  2021-06-24
v1.5      2021-12-20
v1.6	  2022-02-25
v1.7	  2022-06-03 No real fuctional changes.

OVERVIEW
Version 1.1 of the meter AOI's require version 4.04 firmware.
Version 1.1 of the main AOI requires version 4.04 firmware.

History of changes: MVI69E_AFC_AddOn_Rung_DifferentialGas
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.2      2019-10-23   KS   Added Flow Rate Process Input and Flow Rate Alarm Controller Tags for Flow Rate Devices (and not just for Differential Pressure).
v1.3      2020-03-23  IJL   Addition of default process input data mapping.
v1.4	  2021-06-24   NH   Changed Prescan FLL instruction length from 240 words to 180 for proccess inputs. This stopped mismatch issue
v1.4	  2021-06-24   NH   Made correlation changes between the Module Archive Default UDTs and the AOI Archive Default UDTs.
v1.5	  2021-12-20   NH   1. Made changes to the Flow Rate Primary Input Block ID Insertion in Rung 8 (Removed +1). 
			    2. Modified ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT.
v1.6	  2022-02-25   NH   Updated Tags names AFCMeterXXYYYYYY.BackPlaneReturn.ProcessInputs to AFCMeterXXYYYYYY.BackPlaneReturn.Standard and 
			    AFCMeterXXYYYYYY.BackPlaneReturn.ComponentAnalysis to AFCMeterXXYYYYYY.BackPlaneReturn.Extended.  


History of changes: MVI69E_AFC_AddOn_Rung_DifferentialLiquid
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.2      2019-10-23   KS   Added Flow Rate Process Input and Flow Rate Alarm Controller Tags for Flow Rate Devices (and not just for Differential Pressure).
v1.3      2020-03-23  IJL   Addition of default process input data mapping.
v1.4	  2021-06-24   NH   Changed Prescan FLL instruction length from 240 words to 180 for proccess inputs. This stopped mismatch issue
v1.4	  2021-06-24   NH   Made correlation changes between the Module Archive Default UDTs and the AOI Archive Default UDTs.
v1.5	  2021-12-20   NH   1. Made changes to the Flow Rate Primary Input Block ID Insertion in Rung 8 (Removed +1). 
			    2. Modified ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT.
v1.6	  2022-02-25   NH   Updated Tags names AFCMeterXXYYYYYY.BackPlaneReturn.ProcessInputs to AFCMeterXXYYYYYY.BackPlaneReturn.Standard and 
			    AFCMeterXXYYYYYY.BackPlaneReturn.ComponentAnalysis to AFCMeterXXYYYYYY.BackPlaneReturn.Extended.  


History of changes: MVI69E_AFC_AddOn_Rung_LinearGas
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.2      2020-03-23  IJL   Addition of default process input data mapping.
v1.3	  2021-06-24   NH   Changed Prescan FLL instruction length from 240 words to 180 for proccess inputs. This stopped mismatch issue
v1.3	  2021-06-24   NH   Made correlation changes between the Module Archive Default UDTs and the AOI Archive Default UDTs.
v1.4	  2021-12-20   NH   Modified ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT.
v1.5	  2022-02-25   NH   Updated Tags names AFCMeterXXYYYYYY.BackPlaneReturn.ProcessInputs to AFCMeterXXYYYYYY.BackPlaneReturn.Standard and 
			    AFCMeterXXYYYYYY.BackPlaneReturn.ComponentAnalysis to AFCMeterXXYYYYYY.BackPlaneReturn.Extended.  


History of changes: MVI69E_AFC_AddOn_Rung_LinearLiquid
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.2      2020-03-23  IJL   Addition of default process input data mapping.
v1.3	  2021-06-24   NH   Changed Prescan FLL instruction length from 240 words to 180 for proccess inputs. This stopped mismatch issue
v1.3	  2021-06-24   NH   Made correlation changes between the Module Archive Default UDTs and the AOI Archive Default UDTs.
v1.4	  2021-12-20   NH   Modified ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT.
v1.5	  2022-02-25   NH   Updated Tags names AFCMeterXXYYYYYY.BackPlaneReturn.ProcessInputs to AFCMeterXXYYYYYY.BackPlaneReturn.Standard and 
			    AFCMeterXXYYYYYY.BackPlaneReturn.ComponentAnalysis to AFCMeterXXYYYYYY.BackPlaneReturn.Extended.  


History of changes: MVI69E_AFC_AddOn_Rung_Main
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.1      2019-06-13  JRW   Version 1.1 of the meter AOI's allow component analysis backplane return data to be sent 
                	    properly to the PLC.
v1.1      2019-06-13  JRW   Version 1.1 of the main AOI is the initial revision.
v1.2      2019-10-16  IJL   Update Prove output block length from 24 to 26.
v1.3      2020-03-23  IJL   Ability to set UTC or local date time from ladder.
v1.4	  2021-06-24   NH   Changed Prescan FLL instruction length from 240 words to 180 for proccess inputs. This stopped mismatch issue
v1.4	  2021-06-24   NH   1. Changed COP instruction length from 240 words to 180 on rung 19 for procces inputs to output block. 
			    2. Modified ProfileBlockID INT to DINT.
v1.5	  2021-12-20   NH   Modified ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT.


History of changes: MVI69E_AFC_AddOn_Rung_Network
Ver#         Date     Doer  Desc
-----     ----------  ----  ----------------------------------------------------------------------------------------
v1.0      2019-10-02  IJL   Addition of MVI69E_AFC_AddOn_Rung_Network_v1_0.L5X allows user to read and write module network configuration.  
v1.1      2021-12-21  NH    Made changes to the ModbusGatewayConfig UDT StartRegister Tag Data Type from INT to DINT. 

This zip file MVI69E_AFC+SAMPLE+LADDERS.zip contains the following files:
MVI69E_AFC_AddOn_Rung_DifferentialGas_v1_6.L5X - Add on rung for use with differential (orifice) gas meters.
MVI69E_AFC_AddOn_Rung_DifferentialLiquid_v1_6.L5X - Add on rung for use with differential (orifice) liquid meters.
MVI69E_AFC_AddOn_Rung_LinearGas_v1_5.L5X - Add on rung for use with linear (turbine) gas meters.
MVI69E_AFC_AddOn_Rung_LinearLiquid_v1_5.L5X - Add on rung for use with linear (turbine) liquid meters.
MVI69E_AFC_AddOn_Rung_Main_v1_5.L5X - Add on rung used to communicate with the module.
MVI69E_AFC_AddOn_Rung_Network_v1_1.L5X - Add on rung used network communication with the module.
MVI69E_AFC.ACD - Sample ladder containing all meter types.
README.txt - This file. 