Prosoft Technology Inc
README FILE FOR MVI56-AFC SAMPLE LADDER PROGRAMS
Date: 10/13/08

OVERVIEW
This zip file MVI56_AFC SAMPLE LADDERS.zip contains the following files: 

MVI56AFC_AddOn_Rung_v1_2.L5X	- Import rung file for RSLogix v16 and greater (with Add-On instruction) 
MVI56_AFC_v20.ACD 		- Sample ladder program for RSLogix v20 (with Add-On instruction)
MVI56_AFC_v19.ACD 		- Sample ladder program for RSLogix v19 (with Add-On instruction)
MVI56_AFC_v18.ACD 		- Sample ladder program for RSLogix v18 (with Add-On instruction)
MVI56_AFC_v17.ACD 		- Sample ladder program for RSLogix v17 (with Add-On instruction)
MVI56_AFC_v16.ACD 		- Sample ladder program for RSLogix v16 (with Add-On instruction)   
MVI56_AFC_v15.ACD 		- Sample ladder program for RSLogix v15  
MVI5_6AFC_v13.ACD 		- Sample ladder program for RSLogix v13
README.TXT       		- Readme file   


SELECTING THE SAMPLE LADDER FILE

>For ControlLogix version 16.xx.xx and greater

RSLogix version 16 introduced the Add-On instruction funcionality that allows
the encapsulation of several ladder rungs into one single instruction. The sample 
ladder logic for v16 uses the Add-On instruction in order to provide a quick and easy
setup procedure for your MVI56-AFC module.
You can either import the required components into your existing ladder through the 
MVI56AFC_AddOn_Rung_v1_2.L5X file or refer to the sample ladder file MVI56_AFC_v16.ACD or greater. 

In order import the required components into your existing ladder program follow
the steps below:  

1) Create a new RSLogix project for version 16 or greater

2) Create a new module 1756-MODULE (I/O Configuration) with the following settings: 

Name                            = MVI56AFC
Comm Format                     = Data-INT
Input Assembly Instance         = 1
Input Assembly Size             = 250
Output Assembly Instance        = 2
Output Assembly Size            = 248
Configuration Assembly Instance = 4
Configuration Assembly Size     = 0

Adjust the Slot and RPI settings for your application.

Note - recommended RPI time is 5.0ms for local rack applications. 

3) Write-click at the rung where the Add-On instruction will be inserted.
Select Import Rung... and select the MVI56AFC_AddOn_Rung_v1_2.L5X file.  During the import 
procedure associate the input and output images with the ones generated 
during step 1 (default are for slot 1). 

4) Once the import procedure is completed the Add-On instruction will be 
displayed at the ladder rung. The procedure has also imported new data types
and controller tags. 

5) Verify the project 

6) Save the project

7) Download the project to the ControlLogix processor


You can also refer to the sample ladder MVI56_AFC_v16.ACD or greater that already 
contain the complete project with the Add-On instruction and module created 
with correct settings.



>For ControlLogix version 15.xx.xx

Refer to the sample ladder logic MVI56_AFC_v15.ACD


>For ControlLogix version 13.xx.xx

Refer to the sample ladder logic MVI56_AFC_v13.ACD


USING THE SAMPLE LADDER FILE

For information on how to access the sample program controller tags please refer
to the MVI56-AFC USer Manual. 