We can't wait to see you at Booth #1018 at Automation Fair® 2019 Click here to register.
MVI56-PDPMV1 Picture

PROFIBUS DP-V1 Master Network Interface Module for ControlLogix

MVI56-PDPMV1

The MVI56 PROFIBUS DP-V1 Master Network Interface Module allows ControlLogix processors to easily communicate with slave devices supporting PROFIBUS DP-V0 and DP-V1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.

Architectures

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Features and Benefits

The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0/V1 protocol.

The module acts as an input/output module between the PROFIBUS network and the ControlLogix processor. Data transfer from the processor is asynchronous with the I/O data transfer on the PROFIBUS network. Databases are user-defined and stored in the module to hold the data required by the protocol.

Specifications

  • Single Slot - 1756 backplane compatible
  • The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module
  • Ladder Logic is used for data transfer between module and processor. Sample ladder file (add-on instruction) included.
  • Local or remote rack
  • Configurable I/O backplane sizes allow optimal performance for remote rack applications
  • CIPconnect™ enabled. Module supports communications with ProSoft Configuration Builder and FDT comDTM via Ethernet routing using Rockwell Automation Ethernet interface.

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5.1 VDC
3mA @ 24 VDC

Operating Temperature

32° F to 140° F (0° C to 60° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Shock

30 g Operational
50 g non-operational

Vibration

5 g from 10 to 150 Hz

Relative Humidity

5% to 95% (without condensation)

LED Indicators

Module Status

Backplane Transfer Status

Application Status

Serial Activity and Error LED Status

Debug/Configuration port (CFG)

CFG Port (CFG)

RJ45 (DB-9M with supplied cable)

RS-232 only

CIPconnect™ Ethernet routing using 1756-ENBT, 1756-EN2T or similar

Shipped with Unit

RJ45 to DB-9M cables for each port

6-foot RS-232 configuration cable

Certifications

Ex Certificate (ATEX Directive) 79.81 kB Last Modified 11/01/2012
CB Safety 41.99 kB Last Modified 11/01/2012
Declaration of Conformity (RoHS/CE) 301.57 kB Last Modified 03/04/2018
Russian GOST-R 1.23 MB Last Modified 11/01/2012
Korean KC Registration 559.09 kB Last Modified 11/01/2012
Lloyd's Register 2.13 MB Last Modified 11/01/2012
UL/cUL; Class 1, Div 2 1.12 MB Last Modified 02/27/2019
UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 02/27/2019