PLX51-PBM

PROFIBUS DP Master/Slave to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial Gateway

PLX51-PBM

The PLX51-PBM gateway provides connectivity to EtherNet/IP™, Modbus TCP/IP®, or Modbus® Serial networks for PROFIBUS DP networks by operating as either a Master or Slave device on the PROFIBUS DP network.

For easy integration to a Rockwell Automation Controller, the gateway and configuration software create dynamic AOI’s based on the user configuration to add logical tag names to the PLC project file. Thus, reducing the overall programming time for EtherNet/IP applications.

For configuration of Modbus TCP/IP or Modbus Serial Networks, the module will automatically map PROFIBUS DP data points to registers on a Modbus network.

With advanced tools such as PROFIBUS device discovery and a built-in PROFIBUS DP packet capture utility, PROFIBUS DP network commissioning time can be greatly reduced.

Dual Ethernet ports of the module can support either DLR (Device Level Ring) topology, or can be used as an embedded switch for flexible installation options.

With support for up to 1536 bytes of Input and Output data, and up to 4 EtherNet/IP connections to the processor, this module provides performance and data throughput back to the processor for even the most demanding of PROFIBUS applications.

When used as a PROFIBUS DP slave, the module can operate as 1 to 10 slaves, providing up to 1536 bytes of Input and Output Cyclic I/O data between EtherNet/IP, Modbus TCP/IP, or Modbus Serial devices and a PROFIBUS DP master.

Architectures

Click on image(s) to enlarge
Drag with the mouse. Click for close.

Features and Benefits

  • Supports DLR for EtherNet/IP networks
  • Support for either EtherNet/IP, Modbus TCP/IP, or Modbus Serial Communication networks.
  • PROFIBUS master or slave (with multi-slave support)
  • Built-in PROFIBUS packet capture tool

Configuration

The PLX50 Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the PROFIBUS DP network, connections with Rockwell Automation controllers and devices over EtherNet/IP, and build custom Add-On Instructions (AOIs) to be imported into Studio 5000 applications. 

With the ability to import custom AOI’s into the Studio 5000 environment and advanced PROFIBUS DP tools such as the packet capture utility, commissioning time of a network can be greatly reduced.  

Specifications

EtherNet/IP™ Server

As an EtherNet/IP server, the gateway can support up to 4 Class 1 I/O connections back to a Controller on an EtherNet/IP network. Additionally, the server can respond to Class 3 messages from an EtherNet/IP client for the transfer of Status and PROFIBUS DP data.

Modbus TCP/IP

On a Modbus TCP/IP network, the module will operate as either a Modbus TCP/IP Client or Server device.

As a Modbus TCP/IP client the module can be configured to automatically read/write all PROFIBUS DP data with a slave device for easy setup and configuration, or the Modbus Auxiliary Map feature will allow you to configure data transfer to customize the mapping to meet specific application requirements.

As a Modbus TCP/IP Server all information from the PROFIBUS DP network is stored in continuous registers in the module for easy configuration and efficient mapping of data to a Modbus TCP/IP client.

Modbus Serial

On a Modbus Serial network the module will operate as either a Master or a Slave device supporting either RS232 or RS485 communication networks.

As a Modbus Serial Master the module can be configured to automatically read/write all PROFIBUS DP data with a slave device for easy setup and configuration, or the Modbus Auxiliary Map feature will allow you to configure data transfer to customize the mapping to meet specific application requirements.

As a Modbus Serial Slave all information from the PROFIBUS DP network is stored in continuous registers in the module for easy configuration and efficient mapping of data to an attached master device.

PROFIBUS DP Master V1

Cyclic or acyclic data can be transferred with Class 1 or Class 2 DPV1 services, allowing communication with slave devices supporting PROFIBUS DPV0 or V1 protocols. The gateway acts as an input/output link between the PROFIBUS network and the EtherNet/IP protocol. Data transfer by the EtherNet/IP protocol is asynchronous from data transfer on the PROFIBUS network.

  • Easy-to-use drag and drop configuration interface via ProSoft PLX50 Configuration Utility
  • GSD file import library
  • Monitoring and Modification of process data and DPV1 acyclic data
  • Multi-drop on a PROFIBUS DPV1 network with other compatible devices
  • Automatic project documentation, and Bus Parameter calculation
  • Supports online slave diagnostics, and extended diagnostic data (DPV1)
  • Auto baud detection at all valid PROFIBUS DPV1 rates up to 12 Mbps
  • Master Status LED Indicators for Operations, Network Communication, Master Token-Hold and Network Configuration.
  • Up to 125 Slaves can be connected with a repeater
  • Up to 1536 cyclic bytes input and 1536 bytes output data
  • Supports Extended Diagnostic Data
  • Alarm Handling (DPV1)
  • Supports Sync and Freeze commands
  • Supports PROFIdrive 3.1 compliant parameter read and write operations
    • Supports Multicast and Broadcast telegrams (DPV1)

 

EtherNet/IP

Mode

Adapter

Connector

RJ45

Conductors

CAT5 STP/UTP

ARP Connections

Max 40

TCP Connections

Max 40

CIP Connections

Max 10

Communication Rate

10/100Mbps

Duplex Mode

Full / Half / Auto Negotiate

Auto MDIX

Yes

Modbus TCP/IP

Mode

Client or Server

Connector

RJ45

Conductors

CAT5 STP/UTP

ARP Connections

Max 40

Communication Rate

10/100Mbps

Duplex Mode

Full / Half / Auto Negotiate

Auto MDIX

Yes

Modbus Serial

Mode

Master or Slave

Media

RS232 or RS485

Baud Rate

1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k, 115.2k

Data Bits

8

Stop Bits

1

Parity

None, Odd, Even

PROFIBUS DP

Protocol

PROFIBUS DP Master or Slave

Baud Rate

9600, 19.200, 45.5 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps

Support

DPV0 or DPV1

Cyclic I/O data

Input: 1536 bytes, Output: 1536 bytes

Stop bits

1

Hardware

Specification

Description

Emissions

IEC 61000-6-4

ESD Immunity

EN 61000-4-2

Radiated RF Immunity

IEC 61000-4-3

EFT/B Immunity

IEC 61000-4-4

Surge Immunity

IEC 61000-4-5

Conducted RF Immunity

IEC 61000-4-6

Physical

Specification

Description

Enclosure Rating

IP20, NEMA/UL Open Type

Temperature

-20 to 70 °C

Earth Connection

Yes, terminal based

Dimensions (H x W x D)

5.86 x 1.33 x 4.56 in
149 x 34 x 116 mm

Power Requirements

Input: 10 to 36V DC

Power Consumption

85mA @ 24V => 2.04W

Power Connector

3-way terminal

Conductors

24 to 18 AWG

Certifications

ATEX Letter of Conformity 278.54 kB Last Modified 05/12/2022
CB Safety 1.97 MB Last Modified 09/04/2019
UL/cUL; Class1, Div 2 235.70 kB Last Modified 09/04/2019
ODVA EtherNet/IP Declaration of Conformity 37.88 kB Last Modified 09/04/2019
Declaration of Conformity (RoHS/CE) 139.57 kB Last Modified 11/16/2022
Declaration of REACH Compliance 128.14 kB Last Modified 11/16/2022
Country Approval - Korea - KC Registration 281.75 kB Last Modified 05/12/2022
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB Last Modified 02/11/2022
Korean KC Registration 281.75 kB Last Modified 04/28/2022