The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
Command List |
Up to 16 commands per client, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count. |
||
Supported Modbus Function Codes |
1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register |
15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (server only) 23: Read/Write Holding Registers (server only) |
|
Supported clients |
10 |
||
Supported servers |
MBAP = 5, Encapsulated = 5 |
||
Command List |
Up to 160 fully configurable client commands |
||
Status Data |
Error codes reported individually for each command |
||
Command List Polling |
Each command can be individually enabled or disabled; write-only-on-data-change is available |
||
|
|
|
|
Specification |
Description |
Driver Type |
Class A Device |
PROFINET I/O Data |
1440 bytes IN, 1440 bytes OUT |
Exchange Types |
Cyclic Real-time (RT) and Acyclic Data |
Specification |
Description |
Power Supply |
24 VDC nominal |
Current Load |
24 VDC nominal @ 300 mA 10 to 36 VDC @ 610 mA maximum |
Operating Temperature |
-25°C to 70°C (-13°F to 158°F ) |
Storage Temperature |
-40°C to 80°C (-40°F to 176°F ) |
Relative Humidity |
5% to 95% RH with no condensation |
Shock |
IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational) IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational) |
Vibration |
IEC 60068-2-6; 5G @ 10 to 150 Hz |
Dimensions |
5.38 x 1.99 x 4.38 in |
LED Indicators |
*Configuration (CFG) *Error Status (ERR) *Power (PWR) *Hardware Fault (FLT)
*Network Status (NS) Modbus TCP/IP Class I or Class III Connection Status (Modbus TCP/IP only)
*Module Configuration Status (Modbus TCP/IP only) |
Ethernet Port
|
*10/100Mbit RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 |
Shipped With Each Unit |
2.5 mm screwdriver, J180 Power Connector |
ATEX Letter of Conformity | 107.32 kB | Last Modified 05/12/2022 |
CB Safety | 348.30 kB | Last Modified 10/20/2022 |
Korean KC Registration | 974.32 kB | Last Modified 07/07/2020 |
Profibus/Profinet Certificate | 323.99 kB | Last Modified 05/22/2015 |
UL Certificate of Compliance | 233.35 kB | Last Modified 11/16/2022 |
Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) | 1.92 MB | Last Modified 07/10/2020 |
Declaration of Conformity (RoHS/CE) | 114.24 kB | Last Modified 06/01/2022 |
Declaration of REACH Compliance | 145.49 kB | Last Modified 06/01/2022 |