Home » Categories » Gateways » 7000 Series - AppSrvCE |
I get an "echoxmlcfg failure" message whenever I try to download an EZ-Studio project to my ProSoft 7000 Historian. How do I fix this? |
Article Number: 373 | Rating: Unrated | Last Updated: Mon, Jun 30, 2014 at 11:12 PM |
Running the TEMU.exe utility in the /DiskOnChip area of the appsrv's file system resolves this. If you are using OPC, then Register OPC Components checkbox should be checked. The utility will walk you through the maze of unlocking the registry. Once the registry is unlocked, this utility will register the appropriate DLLs and EXEs. After successfully running the utility, you should cycle power and determine whether or not the problem has been corrected. If the problem persists the next possibility is a COM/DCOM problem. OSISoft made heavy use of these technologies for communication between the ECHO components. As such they would need to be consulted as to why the "Failed to connect" problem occurred. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
I'm developing applications for the AppServ CE and need to know, how do I get applications to auto-start on power-up?
Viewed 1 times since Wed, Mar 19, 2008
How do I change the video display resolution in the AppSrv?
Viewed 1 times since Wed, Nov 29, 2006
How does one autostart an application in the appsrvce?
Viewed 1 times since Fri, Aug 31, 2007
Why is COM port 1 not available on the AppSrvCE unit?
Viewed 1 times since Mon, Jun 30, 2014
How do I setup the IP Address in an AppSrvCE?
Viewed 1 times since Thu, Jan 25, 2007
Every attempt to download an EZ-Studio project to the AppServ module results in an "echoxmlcfg" failure. How do I fix this?
Viewed 1 times since Mon, Feb 18, 2008
How do I get AppServCE applications to Auto-Start on power-up?
Viewed 1 times since Thu, Apr 24, 2008
How do I do a Remote Display Connection with the AppSrvCE?
Viewed 1 times since Thu, Jan 25, 2007
What can I do to troubleshoot connection problems between Echo Historian and OPC/SLS servers on the PC56/PC56CE/7000AppSrvCE platforms?
Viewed 1 times since Wed, Feb 6, 2008
|