• English
  • 中文
  • Français
  • Deutsch
  • Español
Contact Us
Home
Email
Follow Prosoft Technology on Twitter
Follow Prosoft Technology on Facebook
Follow Prosoft Technology on LinkedIn
Follow Prosoft Technology on YouTube
    • PROFINET Controller Module for ControlLogix®
    • EtherNet/IP™ to DH+ Gateway
    • Two-Port Building Automation Gateway
  • Solutions
    • Amusement
    • Automated Material Handling
    • Automotive
    • IIoT Solutions
    • Stand-Alone Protocol Gateways

      Products

      • Remote Access
      • Rockwell Automation In-chassis
      • Gateways
      • Industrial Wireless
      • ProSoft Software
      Gateways  >  Aparian  >  Modbus Router/B
      Find a Distributor Request Pricing
      Modbus Router/B

      Modbus Router/B

      A-MBR/B

      The Modbus® Router/B provides intelligent data routing between Logix controllers/PLCs and Modbus devices via Modbus RTU (RS232 / RS485) or Modbus TCP. The Router can operate as either a Modbus Client (Scheduled Mode) or Modbus Server (Reactive Mode).

      Communications with a Logix controller (e.g., ControlLogix® or CompactLogix™) can be achieved via EtherNet/IP™ or USB. Direct-to-Tag technology enables the router to exchange data directly with Logix Tags, thus requiring no Logix programming.
      When using USB, a redundant system can be configured using one Router for each Logix controller. Only the Router connected to the Primary Logix controller will respond to the Modbus TCP requests.

      The Router also supports the MicroLogix™ and SLC™500 platforms.

      The Router hosts two Ethernet ports which can be configured in a Device Level Ring or Linear topology.

       

      • Architectures
      • Features and Benefits
      • Specifications
      • Hardware
      • Downloads
      • Certifications

      Architectures

      Click on image(s) to enlarge
      Drag with the mouse. Click for close.
      Drag with the mouse. Click for close.
      Drag with the mouse. Click for close.

      Features and Benefits

      • The MBR/B can operate as a Modbus Client or Modbus Server.
      • Modbus Client mode can communicate with up to 100 Modbus Servers.
      • Supports Modbus passthrough messaging.
      • Modbus Server mode supports full Modbus data range.
      • Modbus Server mode supports emulating multiple Modbus nodes.
      • Configurable Modbus TCP Port numbers.
      • Supports EtherNet/IP Target and Originator modes:
        • EtherNet/IP Target (Class 1 connection)
        • EtherNet/IP Originator (Class 1 connection with up to 10 EtherNet/IP devices and Explicit Messaging, including Direct-To-Tag Logix tag access, with up to 10 EtherNet/IP devices)
      • Supports CIP USB interface for Logix controllers.
      • EtherNet/IP Class 1 target connections support 2kbyte input and 2kbyte output data to Logix input and output assemblies.
      • Supports Modbus media conversion allowing for a transparent link from one media to another (e.g., Modbus TCP to Modbus RTU232).
      • Slate provides a Modbus packet capture utility for better diagnosis.
      • Dual Ethernet ports which support Device-Level-Ring (DLR).
      • Network Time Protocol (NTP) supported for external time synchronization.
      • Small form factor – DIN rail mounted.

      Specifications

      Ethernet

      Specification

      Description

      Connector

      RJ45

      Conductors

      CAT5 STP/UTP

      ARP Connections

      200 max.

      TCP Connections

      200 max.

      CIP Connections

      20 max.

      Communication Rate

      10/100 Mbps

      Duplex Mode

      Full / Half

      Auto-MDIX

      Supported

      Controller Support

      ControlLogix, CompactLogix, MicroLogix, SLC

      Embedded Switch

      Yes, 2 x Ethernet ports

      Device Level Ring (DLR)

      Supported

      Network Time Protocol (NTP)

      Supported

       

      Serial Ports (RS232, RS485)

      Specification

      Rating

      Connector

      9-way terminal (shared)

      Conductor

      24 to 18 AWG

      Electrical Isolation (RS232)

      1000 VDC

      Electrical Isolation (RS485)

      1500 Vrms (1 minute)

      Baud Rate (bps)

      1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

      Parity

      None, Even, Odd

      Data, Stop Bits

      8, 1

       

      USB Port

      Specification

      Description

      USB Supported

      USB2.0

      Module USB Connector

      Type-A

      Recommended USB Cable

      Type-A (male) to Type-B (male)

       

      Modbus – Reactive / Scheduled Mode

      Specification

      Rating

      Reactive Tag mode

      Max 100 mapping items

      Scheduled Tag mode

      Max 100 mapping items

      Application Functions
      Supported

      Read Coil, Read Discrete Input, Read Holding Register, Read Input Register,
      Write Coil, Write Register

      Maximum Logix Controller
      support

      3 (when using Ethernet)

      1 (when using USB)

      Protocols

      Modbus RTU (RS232 or RS485), Modbus TCP

       

      Modbus Client - Enhanced Mode

      Specification

      Description

      Modes Supported

      Modbus TCP, Modbus RTU232, Modbus RTU485

      Modbus RTU485 Termination

      125 Ω - Software Enabled

      Modbus Server Devices

      100 max.

      Modbus Mappings

      100 max.

      Mapping Ranges

      Holding Register: 0 to 65535
      Input Register: 0 to 65535
      Input Status: 0 to 65535
      Coil Status: 0 to 65535

      Base Offset

      Modbus (base 0), PLC (base 1)

      Configurable Modbus TCP Port

      Yes

      Data Re-formatting Supported

      BB AA
      BB AA DD CC
      CC DD AA BB
      DD CC BB AA

       

      Modbus Server - Enhanced Mode

      Specification

      Description

      Modes Supported

      Modbus TCP, Modbus RTU232, Modbus RTU485 (simultaneous)

      Modbus RTU485 Termination

      Software set

      Mapping Ranges

      Holding Register: 0 to 65535
      Input Register: 0 to 65535
      Input Status: 0 to 65535
      Coil Status: 0 to 65535

      Base Offset

      Modbus (base 0), PLC (base 1)

      Configurable Modbus TCP Port

      Yes

       

      EtherNet/IP Target

      Specification

      Description

      Class 1 Cyclic connection count

      5

      Logix Direct-to-Tag Supported

      Yes

       

      EtherNet/IP Originator

      Specification

      Description

      Class 1 Cyclic Connections Supported

      Yes

      Class 3 / UCMM Connections Supported

      Yes

      Class 1 Connection Count

      10

      Class 3 / UCMM Target Device Count

      10

      Class 3 / UCMM Mapping Count

      50

       

       

       

       

      Hardware

      Specification

      Description

      Power Supply

      Input: 10 to 32 VDC, (121 mA @ 24 VDC)

      Voltage Fluctuations

      Voltage fluctuations < ±10%
      Transient Over-voltages up to the levels of OVERVOLTAGE CATEGORY 1

      Power Consumption

      3.1 W (Including full load on USB of 200mA), 300 mA maximum

      USB Power

      5V, maximum load of 200 mA (1W)

      Dimensions (H x W x D)

      149.0 x 34.0 x 116.0 mm

      Connector

      3-way terminal

      Conductors

      24 to 18 AWG

      Enclosure Rating

      IP20, NEMA/UL Open Type
      Indoor use only

      Temperature

      -20 to 70 °C

      Relative Humidity

      5% to 90% - No condensation

      Pollution Degree

      2

      Altitude

      < 2000 m

      Earth Connection

      Yes, terminal based

      Emissions

      IEC 61000-6-4

      ESD Immunity

      EN 61000-4-2

      Radiated RF Immunity

      IEC 61000-4-3

      EFT/B Immunity

      EFT: IEC 61000-4-4

      Surge Immunity

      Surge: IEC 61000-4-5

      Conducted RF Immunity

      IEC 61000-4-6

      Downloads

      Modbus Router/B Datasheet 512.69 kB Last Modified 02/05/2024
      Modbus Router/B Quick Start Guide 559.76 kB Last Modified 08/28/2025
      Modbus Router/B User Manual 6.67 MB Last Modified 08/28/2025
      Modbus Router/B Firmware v2.001.016 179.67 kB Last Modified 08/28/2025
      Modbus Router/B Release Notes 227.08 kB Last Modified 08/28/2025
      Modbus Router/B EDS Files v1.2 USB 4.20 kB Last Modified 01/25/2024
      Modbus Router/B EDS Files v1.3 4.53 kB Last Modified 01/25/2024
      Modbus Router/B Sample Logic 247.31 kB Last Modified 08/28/2025
      Modbus Router/B Dimension Drawings (STEP) 4.11 MB Last Modified 07/23/2024
      Slate Software v1.089 87.94 MB Last Modified 12/05/2025

      Certifications

      ODVA Certification 37.47 kB Last Modified 01/25/2024
      UL/cUL; Class1, Div 2 238.99 kB Last Modified 01/25/2024
      CE Declaration of Conformity (CE, UKCA, RoHS, UL) 924.07 kB Last Modified 07/18/2025

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater

Products

  • Remote Access
  • Rockwell Automation In-chassis
  • Gateways
  • Industrial Wireless
  • ProSoft Software

Services & Support

  • Knowledge Base
  • Regional Technical Support
  • Legacy Products
  • Training