		RadioLinx Lightning Protection is designed to provide protection for broadband wireless, Wi-Fi, and WLAN systems with low RF power and excellent protection for less exposed subscriber units.
The LP-24002 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure. The connectors are standard N jack connector to standard N jack BH connector. The bulkhead fitting can be connected to any standard N type connector extension cable.
The LP-24003 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure and connecting to a N plug barrel adapter. This can then connect to any antenna with a standard N type connector.
RadioLinx Lightning Protection is designed to protect the radio in the event of a lightning strike. A minimum 6 gauge copper wire should be used to connect the lightning protection to earth ground.
| Surge Capabilities | IEC 1000-4-5, 8/20µs @ 10kA | 
| Frequency Range | 2.0 to 6.0 GHz | 
| Return Loss | > 20 dB | 
| Insertion Loss | ≤ 0.2 dB | 
| RF Power | 10W | 
| Temperature Operating/Storage | -40°to 85°C | 
| Relative Humidity | 0 to 100% condensing | 
| Surge Throughput Energy | ≤ 0.5µJ (6kV/3kA 8/20µs) | 
| Peak Let-Through Voltage | ± 3V (6kV/3kA 8/20µs) | 
| Lightning Protection Datasheet | 113.56 kB | Last Modified 12/14/2009 |