• English
  • 中文
  • Français
  • Deutsch
  • Español
Contact Us
Home
Email
Follow Prosoft Technology on Twitter
Follow Prosoft Technology on Facebook
Follow Prosoft Technology on LinkedIn
Follow Prosoft Technology on YouTube
    • PROFINET Controller Module for ControlLogix®
    • EtherNet/IP™ to DH+ Gateway
    • Two-Port Building Automation Gateway
  • Solutions
    • Amusement
    • Automated Material Handling
    • Automotive
    • IIoT Solutions
    • Mining and Metals
    • Modernization
    • Oil and Gas Solutions
    • Secure Remote Connectivity
    • Water & Wastewater
  • Products
    • Remote Access
    • Rockwell Automation In-chassis
    • Gateways
    • Industrial Wireless
    • ProSoft Software
  • Services & Support
    • Knowledge Base
    • Regional Technical Support
    • Legacy Products
    • Training
    • Return Material Instructions
    • Literature
  • News & Events
    • ProSoft Insights (Blog)
    • Podcast
    • Find a Distributor Request Pricing
      PROFINET Modules

      PROFINET Device Module for ControlLogix®

      ILX56-PND

      The ILX56-PND PROFINET Device Module allows Rockwell Automation® ControlLogix® processors to communicate on a PROFINET RT protocol network supporting up to 1440 bytes of cyclic I/O data.

      Combined with the use of multiple I/O connections back to the ControlLogix processor, this module provides data update rates that will meet even the most demanding of PROFINET RT applications.

      In addition, with the use of the PLX50 Configuration Utility you have advanced features such as custom-built Add-On Routines and User Defined Data Types (UDTs) to minimize the amount of time and effort in getting a ControlLogix PAC operating on a PROFINET RT network.

      The ILX56-PND also supports media redundancy (using the Media Redundancy Protocol – MRP) as well as PROFINET Controller redundancy (using S2 Controller Redundancy).

      • Architectures
      • Features and Benefits
      • Specifications
      • Hardware
      • Downloads
      • Certifications

      Architectures

      Click on image(s) to enlarge
      Drag with the mouse. Click for close.
      Drag with the mouse. Click for close.
      Drag with the mouse. Click for close.

      Features and Benefits

      • Remote diagnostics via configuration utility
      • PROFINET RT Device supporting up to 1440 bytes of Input/Output Data
      • Supports Acyclic parameter data exchange
      • Add-On Profile and custom Add-On Routines and User Defined Data Types provided to allow for seamless integration to Studio 5000
      • Support for S2 Redundancy applications

      Specifications

      PROFINET RT Device Specifications

      Specification

      Description

      PROFINET Device Support

      PROFINET RT Device

      Input/Output

      Maximum 1440 Bytes (input/output) per device

      Minimum Device Interval

      2ms

      Conformance

      Certified to PROFINET Conformance Level B

      Redundancy

      Higher availability through Media Redundancy Protocol (MRP) ring redundancy.
      PROFINET S2 Device Redundancy

      Hardware

      Specification

      Description

      PROFINET Interface

      100/1000 MB with MRP (Client)

      Power Supply

      600 mA @ 5Vdc
      2 mA @ 24 Vdc

      Dimensions

      Standard 1756 Single-slot module

      Burst

      EN 61000-4-4, 2 kV, 5 kHz

      Surge

      EN 61000-4-5, 2 kV Common mode, 1 kV differential mode

      ESD

      EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

      Radiated/Conducted Immunity

      EN 61000-4-3, 10 V/m, 30...1000 MHz, 80% AM, 1 kHz sine wave
      EN 61000-4-6, 10 V, 0,15...80 MHz

      Radiated/Conducted Emission

      EN 55011 Class A

      Vibration/Shock (operating)

      IEC 600068-2-6, 10-500 Hz, ± 0,75 mm, ± 2 g, 1 Octave/min
      IEC 600068-2-27, 30 g, 11 ms

      Operating Temperature

      0°C to 60°C (32°F to 140°F)
      ILX56-PND-CC -25°C to 70°C (-13°F to 158°F)

      Relative Humidity

      5 to 95% (non-condensing)

      Minimum Software Rev

      Studio 5000 v30 and above

      Downloads

      ILX56-PND Datasheet 308.05 kB Last Modified 07/01/2025
      ILX56-PND User Manual 2.11 MB Last Modified 10/30/2025
      ILX56-PNx AOP Files 493.92 kB Last Modified 04/23/2025
      ProSoft PLX50 Configuration Utility
      ILX56-PND Firmware v1.001.015 254.60 kB Last Modified 01/07/2025
      ILX56-PND GSDML Files 48.52 kB Last Modified 01/07/2025
      ILX56-PND EDS Files 2.57 kB Last Modified 01/17/2025
      ILX56-PND CAD Drawings (STEP) 9.41 MB Last Modified 11/05/2024

      Certifications

      PROFINET Certificate 181.79 kB Last Modified 02/11/2025
      UL/cUL 289.17 kB Last Modified 01/09/2025
      CB Safety 112.66 kB Last Modified 03/04/2025
      ATEX Letter of Conformity 100.42 kB Last Modified 01/09/2025
      Declaration of Conformity (RoHS/CE) 729.26 kB Last Modified 10/13/2025
      Declaration of REACH Compliance 396.55 kB Last Modified 12/18/2025

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater