• English
  • 中文
  • Français
  • Deutsch
  • Español
Contact Us
Home
Email
Follow Prosoft Technology on Twitter
Follow Prosoft Technology on Facebook
Follow Prosoft Technology on LinkedIn
Follow Prosoft Technology on YouTube
    • PROFINET Controller Module for ControlLogix®
    • EtherNet/IP™ to DH+ Gateway
    • Two-Port Building Automation Gateway
  • Solutions
    • Amusement
    • Automated Material Handling
    • Automotive
    • IIoT Solutions
    • Mining and Metals
    • Modernization
    • Oil and Gas Solutions
    • Secure Remote Connectivity
    • Water & Wastewater
  • Products
    • Remote Access
    • Rockwell Automation In-chassis
    • Gateways
    • Industrial Wireless
    • ProSoft Software
  • Services & Support
    • Knowledge Base
    • Regional Technical Support
    • Legacy Products
    • Training
    • Return Material Instructions
    • Literature
  • News & Events
    • ProSoft Insights (Blog)
    • Podcast
    • Products for Rockwell Automation Platforms

      Products

      • Remote Access
      • Rockwell Automation In-chassis
      • Gateways
      • Industrial Wireless
      • ProSoft Software
      Rockwell Automation In-chassis  >  PROFIBUS DPV1 PS69 Master Network Interface Module for CompactLogix
      Find a Distributor Request Pricing
      PS69-DPM Picture

      PROFIBUS DPV1 PS69 Master Network Interface Module for CompactLogix

      PS69-DPM

      Limited Availability: Product with low inventory remaining. More Info
      Recommended replacements: ILX69-PBM

      The PS69 PROFIBUS DP Master module expands the functionality of ’s CompactLogix / MicroLogix family of processors to include PROFIBUS. This module supports both I/O control and messaging, thus integrating DPV0 and DPV1 functionality into CompactLogix / MicroLogix.

      The PS69-DPM is a CompactLogix / MicroLogix compatible, PROFIBUS certified module, which enables controllers to communicate with a PROFIBUS network. The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the System Configuration tool . The data exchange between controller and module is done via the I/O process data image using CompactLogix / MicroLogix backplane technology.

      • Architectures
      • Features and Benefits
      • Applications
      • Specifications
      • Hardware
      • Downloads
      • Certifications

      Architectures

      Click on image(s) to enlarge
      Drag with the mouse. Click for close.

      Features and Benefits

      PROFIBUS certified

      Recognized quality certification mark

      FDT configuration software and communication DTM included

      Module DTM will configure master module and network slave devices. The DTM can be used in many FDT compatible software containers

      Sample ladder program

      Simplifies integration for quick and easy project start-up

      Supports CIP ladder logic messaging

      Request diagnostic, status and slave data based on ladder events. Offer better cyclic data performance

      Applications

      Configuration

      The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the PROSOFT.fdt system configuration software tool. PROSOFT.fdt is FDT style configuration software and a communication DTM is included with the module allowing easy configuration of the PROFIBUS Master and network slave devices.

      The master and network configuration are stored in the FLASH memory of the module.

      The PS69-DPM interface appears to the Logix Controller as a standard I/O module and can be configured with RSLogix™ 5000 by Rockwell Automation®.

      Specifications

      Specification

      Description

      Slaves

      Maximum 125

      Input/Output

      Maximum 244 Bytes per Slave

      Input Data

      Maximum 408 Bytes (*)

      Acyclic Data

      DPV1

      Status data

      88 Bytes

      Output data

      Maximum 480 Bytes (*)

      Command data

      16 Bytes

      DPV1 services

      Read / Write class 1, Alarm

      Services

      Global-Control, Slave-Diag, Set-Parameter

      Sync, Freeze Command

      Supported

      Up to 32 PROFIBUS devices can be connected to one bus segment. If several bus segments are linked to each other with repeaters, there can be up to 127 devices on the network.

      The maximum length of a bus segment depends on the baud rate used. Only PROFIBUS certified cable, preferably the cable type A, should be used.

      Baud rate in kBit/s

      Max. Distance

      9.6

      1,200 m / 4000 ft

      19.2

      1,200 m / 4000 ft

      93.75

      1,200 m / 4000 ft

      187.5

      1,000 m / 3280 ft

      500

      400 m / 1300 ft

      1,500

      200 m / 650 ft

      3,000

      100 m / 325 ft

      6,000

      100 m / 325 ft

      12,000

      100 m / 325 ft

      Parameter

      Value

      Impedance

      135 to 65 Ohm

      Capacity

      < 30 pF/m

      Loop resistance

      110 Ohm/km

      Wire gauge

      0.64 mm

      • Single Slot – 1769 backplane compatible
      • The module is recognized as an I/O module and the data exchange between controller and module is done via the I/O data image using CompactLogix / MicroLogix backplane technology.
      • Ladder logic is used for data transfer between module and processor. Sample ladder file included.
      • Supports CompactLogix processors and MicroLogix 1500 LRP

      Hardware

      Specification

      Description

      Processor

      EC1-160P with integrated ASPC2

      PROFIBUS Interface

      RS-485, max. 12 Mbps, potential free, according EN 50170

      Diagnostic Interface

      RS-232, PS/2 Mini-DIN female connector, 9600 Baud, non isolated

      Power Supply

      260 mA at +5 V ±5 %

      Power Supply Distance Rating

      6
      (no more than 6 modules away from the 1769 power supply)

      Dimensions

      Standard 1769 Single-slot module

      Burst

      EN 61000-4-4, 2 kV, 5 kHz

      Surge

      EN 61000-4-5, 2 kV common mode, 1 kV differential mode

      ESD

      EN 61000-4-2, 4 kV contact, 8 kV air, 4 kV indirect

      Radiated/ Conducted Immunity

      EN 61000-4-3, 10 V/m, 30 to 1000 MHz, 80% AM, 1 kHz sinewave

      EN 61000-4-6, 10 V, 0.15 to 30 MHz

      Radiated/ Conducted Emission

      EN 55011 Class A

      Vibration/Shock

      IEC 600068-2-6, 10 to 150 Hz,
       ± 0.75 mm, ± 1 g, 1 Octave/min

      IEC 600068-2-27, 15 g, 11 ms

      Operating Temp.

      32° F to 140° F (0° C to 60° C)

      Relative Humidity

      5% to 95% (without condensation)

      Agency Certification

      C-UL certified, UL 508 listed, CE

      PROFIBUS conformance

      PNO certified

      Downloads

      PS69-DPM Datasheet 309.17 kB Last Modified 11/07/2014
      PS69-DPM User Manual 2.69 MB Last Modified 10/01/2014
      PS69-DPM Add-On Instruction 72.79 kB Last Modified 05/12/2010
      PS69-DPM Ladder 412.07 kB Last Modified 05/17/2010
      Technical Note - Migrating from MVI69-PDPMV1 or PS69-DPM to ILX69-PBM 699.64 kB Last Modified 05/14/2019
      ProSoft FDT Configuration Manager
      LifeCycle Letter PS69-DPx 107.54 kB Last Modified 09/04/2023

      Certifications

      ATEX Letter of Conformity 83.59 kB Last Modified 05/12/2022
      CB Safety 347.28 kB Last Modified 02/26/2020
      CE Mark 91.88 kB Last Modified 02/22/2013
      Country Approval - Eurasian Customs Union Conformity (EAC) (Wired) 1.92 MB Last Modified 07/10/2020
      UL/cUL; Class 1, Div 2 1.12 MB Last Modified 02/27/2019
      UL/cUL; Class 1, Div 2 (Canada) 1.14 MB Last Modified 02/27/2019
      Declaration of Conformity 440.44 kB Last Modified 12/18/2020
      Declaration of REACH Compliance 389.02 kB Last Modified 12/15/2025

Solutions

  • Amusement
  • Automated Material Handling
  • Automotive
  • IIoT Solutions
  • Mining and Metals
  • Modernization
  • Oil and Gas Solutions
  • Secure Remote Connectivity
  • Water & Wastewater

Products

  • Remote Access
  • Rockwell Automation In-chassis
  • Gateways
  • Industrial Wireless
  • ProSoft Software

Services & Support

  • Knowledge Base
  • Regional Technical Support
  • Legacy Products
  • Training
  • Return Material Instructions
  • Literature

News & Events

  • ProSoft Insights (Blog)
  • Podcast
  • Success Stories
  • Press Releases
  • ProSoft Magazine
  • Events

Where to Buy

  • Distributors

About Us