The Process Data Throughput on my RadioLinx Ethernet radios is less than the Max Data Rate shown for the radios. Why is this? |
Article Number: 359 | Rating: 5/5 from 1 votes | Last Updated: Tue, May 5, 2015 at 4:04 PM |
It is important to note that the Maximum Data Transmission Rate is not the same thing as Process Data Throughput. Max Data Rate represents the nominal theoretical maximum amout of data that could be transmitted on the wireless link. This will include ALL data, such as TCP/IP overhead messages, network 'housekeeping' traffic, etc., as well as user process data. Process Data Throughput is the actual volume of user process data transmitted over the wireless link, excluding all the overhead. For this and other reasons, the actual Process Data Throughput will always be less than the theoretical Max Data Rate. Some other factors that lower Process Data Throughput below the Max Data Rate are: pecularities in specific wireless and wired network environments, in-band RF interference, total number of radios in the network, number of repeaters in the network, and most importantly, Ethernet packet size (the smaller the packet size, the higher the ratio of message overhead to useful process data.) Therefore, you should always expect your real-world Process Data Throughput to be less than the Max Data Rate set for the radio system. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
What effects does harsh weather have on my RadioLinx product's signal attenuation?
Viewed 1 times since Tue, Nov 28, 2006
Can the Radio Modem be configured as a repeater?
Viewed 1 times since Tue, Nov 28, 2006
My ILX34-AENWG seems to be running ok. Why can't I get statistics information when viewing the Wireless Statistics webpage from my ILX34-AENWG?
Viewed 1 times since Mon, Sep 28, 2009
Are any ProSoft solutions SIL2 rated?
Viewed 1 times since Tue, Oct 14, 2008
RadioLinx comparison chart
Viewed 1 times since Mon, Mar 8, 2010
How do I upgrade my RLX-OPC Server?
Viewed 1 times since Thu, Jul 2, 2009
I have a serial device which does not use the RS232C standard. It uses a voltage level of +5V for mark and 0V for space. Will this device communicate with RadioLinx products?
Viewed 1 times since Tue, Nov 28, 2006
Are ProSoft RadioLinx radios compatible with Locus radios?
Viewed 1 times since Tue, Nov 28, 2006
|