Home » Categories » Rockwell In-chassis » ControlLogix » PC56 |
How can I setup the PC56-SLS solutions to work with redundant ControlLogix processors? |
Article Number: 370 | Rating: Unrated | Last Updated: Tue, Jul 1, 2014 at 8:11 PM |
All redundancy will be configured and handled in the ControlLogix (CLX) equipment. Besides a redundant-capable CPU, each chassis will need a 1756-CRM module (this takes two slots in a CLX rack), plus an ENBT module in each chassis. This configuration uses all four slots in the local redundant CLX chassis, one for the CPU, two for the CRM, and one for the ENBT. I/O modules will be placed in remote chassis and the PC56 should also be in a remote chassis. The ENBT cards of the two local chassis and the PC56-SLS in a remote chassis will all need to be peers on a local Ethernet spur. Then, whichever redundant CLX CPU is currently the primary CPU will talk to the remote chassis via ControlNet for regular I/O. However, the PC56-SLS will not be able to get data from the Primary CPU via ControlNet but will use Ethernet instead. That's why the Local chassis need to have an ENBT card; not for CPU redundancy but so that the PC56-SLS will be able to get data via Ethernet from whichever CPU is primary. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
What are the differences between the rev A PC56 hardware and the rev B hardware?
Viewed 1 times since Tue, Jan 22, 2008
The PC56-CE sample program in my eMbedded Visual C, hangs my PC when I select 56SAM_FULL in the Select Active WCE Configuration Combo Box.
Viewed 1 times since Tue, Nov 28, 2006
Error: "OCXPAPI could not be found" while browsing tags in PC56-HIST
Viewed 1 times since Wed, Nov 29, 2006
Is there a way to enable/disable the logging feature in ArchestrA Logger (SMC-> PC56-OPC)?
Viewed 1 times since Fri, May 29, 2009
Is Linux available on the PC56?
Viewed 1 times since Thu, Apr 26, 2007
What version of Windows CE is installed on the ProSoft PC56-CE inRAx PC?
Viewed 1 times since Wed, Dec 3, 2008
What can I do to troubleshoot connection problems between Echo Historian and OPC/SLS servers on the PC56/PC56CE/7000AppSrvCE platforms?
Viewed 1 times since Wed, Feb 6, 2008
When trying to connect XML Loader, I get this error: "Failed to connect to the ECHO SDK Node PC56-HIST. -2147023174: The RPC server is unavailable." What do I do?
Viewed 1 times since Tue, Nov 8, 2011
Can I add the 40Gb IDE hard drive to my PC56-XP to supplement the factory installed 4Gb Compact Flash Card?
Viewed 1 times since Fri, Oct 10, 2008
|