MVI94-MCM-MHI Configuration File

What do you need help with?

What is the difference between the 3150-MCM and the MVI46-MCM

registers for data transfer (3150-MCM has 4000) Has direct M1 files access for faster data throughput (3150-MCM must page 50 words of data to the processor at a time) Supports baud rates of up to 115

Read more

What is the heat dissapation for MVI56, MVI56E, MVI69, MVI46 and MVI71 modules?

.1 VDC, 4.08 watts. If you want to convert this to BTU/hr. you would multiply the power dissipation by 3.413, or 13.925 BTU/hr. Using the information noted above if you power the device for one hour

Read more

I need to connect multiple DF1 devices to a single serial port on an SLC or MicroLogix processor, is there a solution?

ProSoft makes a DF1 gateway that functions as a multiplexor.  This permits up to 3 DF1 master devices to communicate to a single SLC or MicroLogix processor while only using a single communication

Read more

Can any Prolinx module support com to SLC5/05 and 3 serial devices?

How can I connect more than one DF1 device to an Allen-Bradley processor's channel 0 port. You will need to use the serial port on a SLC505 to talk to 3 devices. Two of them are MicroLogix over ... Can any Prolinx module support com to SLC5/05 and 3 serial devices?

Read more

How can I monitor module and slave status with the MVI56-PDPV1 and other PDPMV1 PROFIBUS master modules?

. For example, if bits 0 and 3 are set in MVIxxPDPMV1.Status.Fieldbus.FB_Slave_Data_xfer[0], slave addresses 0 and 3 are communicating successfully.  Slave_Data_xfer[1] would contain the booleans representing

Read more