My MVI69 module is not working. What might be wrong? |
Article Number: 405 | Rating: 2/5 from 2 votes | Last Updated: Tue, Jul 1, 2014 at 3:57 PM |
There are many things that may prevent a MVI69 module from working properly. Here is a list of the most commonly overlooked items that can prevent it from working as expected: 1. The Prosoft provided sample ladder logic OR Add-On Instruction (not both) must be loaded into your CompactLogix controller, or included into your existing application. This includes I/O configuration, user-defined datatypes, controller tags, and ladder logic. 2. The CompactLogix CPU must be in RUN mode. The module has to see the processor operating on the 1769 I/O bus before it can complete its boot routine and begin normal operation. 3. The MVI69 modules need 800mA of 5vdc current from the backplane. If the power supply is inadequate, the module will not function normally. 4. The MVI69 modules have a Power Supply Distance Rating of 2. This means they can be installed immediately next to the 1769 power supply on either side or be installed so that there is no more than one other module between them and the power supply one either side. For 1768-L43/45 systems the power supply distance rating starts at the processor and the beginning of the 1769 bus. So the module must be next to the 1768-L43/45 processor, or at most one slot away. 5. Be sure you have a right end cap (1769-ECR) installed to the right of the rightmost I/O module in the system. Without this end cap, the 1769 bus is not properly terminated and the MVI69 modules will not operate correctly. 6. Be sure that in the I/O Configuration section of the ladder logic, on the Connection tab for both the CompactBus Local and the MVI69 module, that the "Inhibit Module" box is NOT checked. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
Will ProSoft MVI69-xxxx solutions work with the new Allen-Bradley CompactLogix L23 series of processors?
Viewed 1 times since Fri, Oct 31, 2008
I have an In-Chassis module, and am seeing a type mismatch shown in the module properties. What is the issue?
Viewed 1 times since Fri, Apr 27, 2007
Is the MVI69 series of ProSoft modules compatible with the MicroLogix1500 processor?
Viewed 1 times since Tue, Nov 28, 2006
Debug port connection parameters for Prosoft modules and gateways
Viewed 1 times since Tue, Nov 28, 2006
RSLogix 500 sample for MVI69-xxx faults MicroLogix processor
Viewed 1 times since Tue, Nov 28, 2006
When using an MVI69-xxx or PS69-xxx module, why does a L43/L45 CompactLogix processor fault immediately after a download or after a power cycle?
Viewed 1 times since Mon, Jan 18, 2010
Do ProSoft CompactLogix modules work with the new CompactLogix processors?
Viewed 1 times since Thu, Mar 5, 2015
IEC-60870-5-104 Server Tutorial
Viewed 1 times since Mon, Sep 3, 2012
|