										Do ProSoft CompactLogix modules work with the new CompactLogix processors?
										 Viewed 1 times  since  Thu, Mar 5, 2015  The requirements for Prosoft's CompactLogix InRAx modules are:  * 1769 I/O bus * 450-800ma @5v from the bus, depending on the MVI module * Placement within 2-4 slots of a CompactLogix power supply, depending on the MVI module  The power and... Read More 
										Debug port connection parameters for Prosoft modules and gateways
										 Viewed 1 times  since  Tue, Nov 28, 2006  Connect PC to module's debug / configuration port using a null-modem cable        Start Hyperterminal, Putty or other comm program and use the following settings:                  bits per second: 57,600           data bits: 8           parity:... Read More 
										I have an In-Chassis module, and am seeing a type mismatch shown in the module properties. What is the issue?
										 Viewed 1 times  since  Fri, Apr 27, 2007  The type mismatch error is always shown since the ProSoft In-Chassis modules do not support the additional functionality required to respond to this inquiry from the processor.  This field does not reflect the status of the ProSoft In-Chassis... Read More 
										RSLogix 500 sample for MVI69-xxx faults MicroLogix processor
										 Viewed 1 times  since  Tue, Nov 28, 2006  I/O mismatch the first versions of our MVI69-XXX sample for MicroLogix processors had the wrong vendor ID code defined under the I/O configuration.   Within the RSLogix 500 program change the vendor ID code from 22 to the correct vendor ID code of... Read More 
										Is the MVI69 series of ProSoft modules compatible with the MicroLogix1500 processor?
										 Viewed 1 times  since  Tue, Nov 28, 2006  If the controller is an LRP with serial ports and has firmware version 6.0 or greater, then yes, the MVI69 is compatible with the system.     Related Keywords: MVI69 CompactLogix MicroLogix  Read More 
										IEC-60870-5-104 Server Tutorial
										 Viewed 1 times  since  Mon, Sep 3, 2012  The following document outlines the ProSoft implementation of the IEC-60870-5-104 Server communication module as pertains to all -104S products.  Read More 
										Will ProSoft MVI69-xxxx solutions work with the new Allen-Bradley CompactLogix L23 series of processors?
										 Viewed 1 times  since  Fri, Oct 31, 2008  ProSoft  MVI69 solutions require a minimum of 800mA of 5vdc current be available from the backplane of any CompactLogix system in which they are installed.  Within the 1769-L23x processor family, our MVI69-xxx modules will work with some but not... Read More 
										When using an MVI69-xxx or PS69-xxx module, why does a L43/L45 CompactLogix processor fault immediately after a download or after a power cycle?
										 Viewed 1 times  since  Mon, Jan 18, 2010  A firmware anomaly has been identified in version 17 for the CompactLogix 1768-L43 and L45 processor that will not work properly when using any Prosoft MVI69 or PS69 communication modules.  FRN 18 will correct the issue.    Work around's... Read More 
										My MVI69 module is not working.  What might be wrong?
										 Viewed 1 times  since  Fri, Oct 10, 2008  There are many things that may prevent a MVI69 module from working properly.  Here is a list of the most commonly overlooked items that can prevent it from working as expected:    1.  The Prosoft provided sample ladder logic OR Add-On... Read More | ||||||||||||||