Where are the on-board jumper positions defined for my MVI module?
Viewed 1 times since Tue, Nov 28, 2006
On bottom of the circuit board for any MVI products, you' ll find three jumper banks: COM1, COM2, and Setup. Each jumper position is labeled 232, 422 and 485. Read More
For what purposes would I use the Multiple Meter Streams options on my MVIxx-AFC Flow Computer?
Viewed 1 times since Wed, Mar 19, 2008
The Multiple Meter Streams options can be used to more efficiently compute flows through a single meter at a physical site that has different fluids flowing through the meter at different times.  Since each Stream will... Read More
Do ProSoft AFC flow computer solutions support energy calculations according to the ISO-6976 standards?
Viewed 1 times since Thu, Feb 7, 2008
ProSoft AFC flow computer modules implement the Bernoulli equation for measurement of fluid flow through concentric square-edged orifices. The Coefficient of Discharge in this equation is calculated by an appropriate Standard, which may, by option... Read More
Do ProSoft AFC Flow Computers support annubar-type flow sensors?
Viewed 1 times since Tue, Jul 8, 2008
No, the annubar is a different kind of differential pressure sensor; It is essentially a multiple pitot tube, which requires a different kind of calculation than an orifice plate. Read More
Do ProSoft AFC Flow Computer solutions support "ASME MFc-6M", "API-11" and/or "API-12" calculation standards for measuring lubricating oils?
Viewed 1 times since Tue, Jul 8, 2008
The API-11 and API-12 calculations are available in ProSoft AFC Flow Computers, beginning with version 2.05.   MPMS Ch 12 specifies, essentially, the necessary factors and calculational sequence for measuring liquids, and the... Read More
The Wallclock in my ProSoft MVIxx-AFC module seems to be showing Greenwich Mean Time (GMT or Universal Time) instead of Local Time. How do I get it to use Local Time?
Viewed 1 times since Wed, Dec 3, 2008
First of all, be sure your processor is showing Local Time and that you have run the "Set Clock" routine from the AFC logic to synchronize the MVIxx-AFC Wallclock to the processor time. If the processor shows correct local time and the MVIxx... Read More
Using AFC modules with corrected (net) flow as in input
Viewed 1 times since Fri, Sep 19, 2014
The AFC is not designed to receive a corrected flow input. However if the AFC is being used only for its accumulation and archive capabilities, then rather than the process temperature and pressure inputs, provide the meter's reference... Read More