The Wallclock in my ProSoft MVIxx-AFC module seems to be showing Greenwich Mean Time (GMT or Universal Time) instead of Local Time. How do I get it to use Local Time? |
Article Number: 423 | Rating: Unrated | Last Updated: Thu, Mar 5, 2015 at 10:01 PM |
First of all, be sure your processor is showing Local Time and that you have run the "Set Clock" routine from the AFC logic to synchronize the MVIxx-AFC Wallclock to the processor time. If the processor shows correct local time and the MVIxx-AFC shows GMT after the Set Clock routine has been run and you are using RSLogix5000, version 16 or higher, and are using the ProSoft Add-On Instruction (AOI), you may have an older version of that AOI that called the "DateTime" clock parameter from the processor rather than the "LocalDateTime" parameter. You can correct this situation by downloading and installing the latest version of the AOI from the appropriate product web page Downloads link. If you decide to use the newest AOI, please be sure to delete the previous AOI ladder instruction and rungs, the previous controller tags, and the previous User-defined Data Types (UDTs) before you import the new AOI rung. You should leave the I/O configuration in place. The new import will re-create all these deleted items for you, as well as correct the Wallclock issue. Be sure to run the Set Clock routine after re-importing the new AOI. At that point, the MVIxx-AFC module Wallclock and the processor date and time should agree. |
Attachments (0)
There are no attachments for this article.
|
Comments
There are no comments for this article. Be the first to post a comment.
|
Downloading a new .AFC project file to an AFC flow computer module.
Viewed 1 times since Tue, Nov 28, 2006
Do ProSoft AFC flow computer solutions support energy calculations according to the ISO-6976 standards?
Viewed 1 times since Thu, Feb 7, 2008
For what purposes would I use the Multiple Meter Streams options on my MVIxx-AFC Flow Computer?
Viewed 1 times since Wed, Mar 19, 2008
What are the power requirements for the MVI69 CompactLogix modules?
Viewed 1 times since Tue, Nov 28, 2006
Where are the on-board jumper positions defined for my MVI module?
Viewed 1 times since Tue, Nov 28, 2006
Do ProSoft AFC Flow Computers support annubar-type flow sensors?
Viewed 1 times since Tue, Jul 8, 2008
How do I configure a vortex, ultrasonic or coriolis type meter in my AFC module?
Viewed 1 times since Tue, Nov 28, 2006
Do ProSoft AFC Flow Computer solutions support "ASME MFc-6M", "API-11" and/or "API-12" calculation standards for measuring lubricating oils?
Viewed 1 times since Tue, Jul 8, 2008
Is it possible to configure an AFC flow computer solutions to use the ISO 6976 computation standard?
Viewed 1 times since Thu, Apr 24, 2008
Using AFC modules with corrected (net) flow as in input
Viewed 1 times since Fri, Sep 19, 2014
|