Downloading a new .AFC project file to an AFC flow computer module. | 
											
| Article Number: 51 | Rating: Unrated | Last Updated: Wed, Dec 31, 2014 at 4:42 PM | 
| 
													
													 You cannot download a new .AFC file while any of the meter runs are enabled, or illegal data values will be reported by AFC manager. First you must disable all meter runs. This can be done either using the AFC manager, or the easier way is through the ladder logic. Once the meter runs are disabled, you may download the new .AFC file. You will then be able to enable the meter runs. Also note that some newer AFC modules ship with a lockout jumper per Measurement Canada requirements. If installed, the jumper must be removed per the instructions near the beginning of the user manual to reconfigure the module.  | 
											
							Attachments (0)  
						 
						
									There are no attachments for this article.
							 	  
						 | 
								Comments   
							 
							
										There are no comments for this article. Be the first to post a comment.
								    | 
										How do I configure a vortex, ultrasonic or coriolis type meter in my AFC module?
										 Viewed 1 times  since  Tue, Nov 28, 2006  
										
									
										Do ProSoft AFC Flow Computer solutions support "ASME MFc-6M", "API-11" and/or "API-12" calculation standards for measuring lubricating oils?
										 Viewed 1 times  since  Tue, Jul 8, 2008  
										
									
										For what purposes would I use the Multiple Meter Streams options on my MVIxx-AFC Flow Computer?
										 Viewed 1 times  since  Wed, Mar 19, 2008  
										
									
										How do I include or calculate a natural gas specific gravity value?
										 Viewed 1 times  since  Mon, Dec 14, 2009  
										
									
										The Wallclock in my ProSoft MVIxx-AFC module seems to be showing Greenwich Mean Time (GMT or Universal Time) instead of Local Time.  How do I get it to use Local Time?
										 Viewed 1 times  since  Wed, Dec 3, 2008  
										
									
										Do ProSoft AFC Flow Computers support annubar-type flow sensors?
										 Viewed 1 times  since  Tue, Jul 8, 2008  
										
									
										Do the serial ports on my MVI56 module provide any electrical isolation?
										 Viewed 1 times  since  Tue, Nov 28, 2006  
										
									
										Using AFC modules with corrected (net) flow as in input
										 Viewed 1 times  since  Fri, Sep 19, 2014  
										
									
										Is it possible to configure an AFC flow computer solutions to use the ISO 6976 computation standard?
										 Viewed 1 times  since  Thu, Apr 24, 2008  
										
									
										Where are the on-board jumper positions defined for my MVI module?
										 Viewed 1 times  since  Tue, Nov 28, 2006  
										
									 | 

						
							
 Add Comment