My Profibus Master (PDPMV1) card is not communicating and will not go into RUN mode but does not show an error in the ProSoft Configuration Builder software, why? |
Article Number: 454 | Rating: Unrated | Last Updated: Thu, May 5, 2011 at 10:03 AM |
Due to GSD file errors or device configuration errrors the module may not be able to go into RUN mode. However depending on the type of error (invalid GSD file or exceeding parameter data configuration) the ProSoft Configuration Builder software may not provide warning messages or feedback of the slave device configuration error(s). An error is reported when the GSD file is downloaded to the PDPMV1 module. This is shown by Profibus LED pattern below: Some possible reasons are: - The GSD file may be invalid, use a GSD file checker software to check this. - The configuration of the network may have exceeded the 240 input or output (each) byte limitation of PDPMV1 memory. - One of the slaves may have an illegal configuration, invalid parameter, duplicate slave ID, etc. |
Attachments (0)
![]()
There are no attachments for this article.
|
Comments
![]()
There are no comments for this article. Be the first to post a comment.
|
SYCON registration number
Viewed 1 times since Tue, Nov 28, 2006
Can a ProSoft PROFIBUS DP v1 Master solution also be configured as a Slave to another Master?
Viewed 1 times since Wed, Mar 5, 2008
How to resolve an issue where Siemens Step 7 software displays a message indicating that the ProSoft GSD file cannot be interpreted.
Viewed 1 times since Wed, Nov 29, 2006
What is Profibus?
Viewed 1 times since Thu, Apr 12, 2007
I am trying to download my PROFIBUS PDPMV1 Master/Slave configuration from the ProSoft Configuration Builder (PCB) "PROFIBUS - PDPMV1" Online-Download Configuration menu option; and it is lo
Viewed 1 times since Tue, Mar 18, 2008
I can't get my ProSoft PROFIBUS DP V1 Master to talk to all of the Slave Nodes on my PROFIBUS network. What might the problem be?
Viewed 1 times since Thu, Sep 4, 2008
I have a PROFIBUS DP network with ProSoft PROFIBUS DP Master solution that appears to be operating normally (no bus faults, slaves report "OK"), but I am unable to control my devices. What
Viewed 1 times since Thu, Apr 24, 2008
I need to set up a ProSoft PROFIBUS Master to talk to a Siemens S7-300 series CPU that is set up as a PROFIBUS Slave. How do I do that?
Viewed 1 times since Mon, Feb 18, 2008
How do I setup my 3170-PDP in Step 7 software?
Viewed 1 times since Tue, Nov 28, 2006
Can a ProSoft PROFIBUS DP v1 Master solution communicate directly with other PROFIBUS DP v1 Masters?
Viewed 1 times since Wed, Mar 5, 2008
|