DF1 Serial Port Expander Gateway

5102-DFS3-DFM

The ProLinx DF1 Serial Port Expander Gateway allows you to attach up to three separate DF1 master devices to a single DF1 slave.

The module is designed to act as a multiplexer, allowing simultaneous connections from multiple DF1 masters to a single DF1 slave. A common use for the module is to have an HMI panel, SCADA software, and Programming software all communicating to the same DF1 channel 0 port of the Rockwell Automation processor.

The module provides a single DF1 Master port and three DF1 Slave ports.

Features and Benefits

Applications

The Serial Port Expander adds three additional slave ports for a DF1 based device. This allows users to connect programming software, HMI, and modems to processors simultaneously. Commands from the host devices are passed through the module and routed directly to the front port of the processor. This allows a processor's port to be expanded to allow communication with a variety of devices at the same time. Typical applications include local ladder configuration, local operator interface, and wireless concentrator for remote programming and data collection.

Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

Downloads

ProSoft Configuration Builder (PCB)
ProLinx Reference Guide 1.52 MB Last Modified 11/12/2014
DFS3 DFM Datasheet 80.19 kB Last Modified 04/26/2010
DFS3 DFM Datasheet (Japanese) 329.48 kB Last Modified 05/06/2010
DFCM Protocol Manual 866.04 kB Last Modified 02/16/2012

Protocols

DF1S Protocol Specifications


Protocol Specifications

DF1 Slave Protocol Specifications

The ports on the PTQ-DFCM module can be individually configured to support the Slave mode of the DF1 protocol. When in the Slave mode, the module can accepts DF1 commands from a Master to read/write data stored in the module's internal registers. This data is easily transferred to the Quantum processor's data registers.

DF1 Slave Driver

Configurable Parameter per slave port

Data Table File Start (File N[X] 0 to 999)

Data Table File Size (1-1000 words)

Data Table location in module (0 to 3999)

DF1 Commands supported

Basic Command Set

0x00: Protected Write

0x01: Unprotected Read

0x02: Protected Bit Write

0x05: Unprotected Bit Write

0x08: Unprotected Write

PLC-5 Command Set (0x0F)

0x00: Word Range Write (Binary Address)

0x01: Word Range Read (Binary Address)

0x00: Word Range Write (ASCII Address)

0x01: Word Range Read (ASCII Address)

SLC Command Set (0x0F)

0xA1: Prot Typed Read with 2 addr fields

0xA2: Prot Typed Read with 3 addr fields

0xA9: Prot Typed Write with 2 addr fields

0xAA: Prot Typed Write with 3 addr fields


DF1M Protocol Specifications


Protocol Specifications

DF1 Master Protocol Specifications

The ports on the PTQ-DFCM can individually be configured as master ports. When configured in the master mode the DFCM module is capable of reading and writing data to remote DF1 devices, enabling the Quantum platform to act as a SCADA sub-master.

DF1 Master Driver

General

Full-Duplex

Master

Half-Duplex

Master

Peer to Peer (Slave to Slave)

DF1 Commands supported

Basic Command Set

0x00: Protected Write

0x01: Unprotected Read

0x02: Protected Bit Write

0x05: Unprotected Bit Write

0x08: Unprotected Write

PLC-5 Command Set (0x0F)

0x00: Word Range Write (Binary Address)

0x01: Word Range Read (Binary Address)

0x26: Read-Modify-Write (Binary Address)

0x00: Word Range Write (ASCII Address)

0x01: Word Range Read (ASCII Address)

0x26: Read-Modify-Write (ASCII Address)

SLC Command Set (0x0F)

0xA1: Prot Typed Read with 2 addr fields

0xA2: Prot Typed Read with 3 addr fields

0xA9: Prot Typed Write with 2 addr fields

0xAA: Prot Typed Write with 3 addr fields

0xAB: Prot Typed Write with Mask 3 addr fields

Command List

Up to 100 command per master port, each fully configurable for function, slave address, register to/from addressing and word/bit count

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained per active master port.

Polling of command list

User configurable polling of commands, including disabled, continuous and on change of data (write only)


Certifications

Ex Certificate (ATEX Directive) 114.27 kB Last Modified 11/11/2013
CB Safety 35.78 kB Last Modified 08/27/2012
CE Mark 92.34 kB Last Modified 02/28/2013
Russian GOST-R 7.07 MB Last Modified 02/22/2013
GOST-R Declaration of Conformity 6.68 MB Last Modified 02/22/2013
UL/cUL; Class 1, Div 2 1.08 MB Last Modified 07/02/2013
UL/cUL; Class 1, Div 2 (Canada) 1.10 MB Last Modified 07/02/2013