Printer friendly version of this page. Find a Distributor near you.
5201-Ethernet & single-Serial

IEC 60870-5-104 Server to IEC 60870-5-103 Master Gateway

5201-104S-103M

Limited Availability: Product with low inventory remaining. More Info

The ProLinx IEC60870-5-104 Server to IEC60870-5-103 Master Gateway creates a powerful connection between devices on an IEC 104 network and an IEC 103 slave device. This stand-alone DIN-rail mounted protocol gateway provides one Ethernet port and one IEC 103 Master configurable serial port.

The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages.

The IEC 60870-5-103 Master protocol driver works as a master to monitor and control up to 16 slaves. The serial port is userconfigurable, providing a very powerful and flexible host or device interface solution.

Features and Benefits

Applications

The 104S-103M modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate an IEC 103 slave device into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Applications

The 104S-103M modules are the ideal solution for the many applications where IEC 104 Server connectivity can be used to integrate an IEC 103 slave device into a system. The IEC60870-5-104 Server gateway is a powerful module designed with Server support, enabling easy connection to other IEC 104 client devices. In combination with the IEC 103 Master device support, the module provides a very powerful interface to the many IEC 103 slave devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Electrical Power.

Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

 

103M Protocol Specification

The IEC 60870-5-103 Master driver provides extensive support for Master implementations of the protocol. The serial port on the gateway is user-configurable to support the IEC protocol (Master, Error Checking, Baud rate, etc).

The module supports:

 

  • 16 slaves (sessions with distinct Data Link Addresses)
  • Each slave (session) supports up to 3 sectors (with distinct Common ASDU Addresses)
  • Configurable Time Sync and General Interrogation messages during initialization
  • Supports General Interrogation, General Command and Time Synchronization Commands

 

General Parameters

Communication parameters

Baud Rate: 110 to 19200 baud

Stop Bits: 1 or 2

Data Size: 5 or 8 bits

Parity: None, Even, Odd

RTS Timing delays: 0 to 65535 milliseconds

IEC 60870-5-103 Master

Configurable Parameters

Baud Rate

Parity

RTS On

RTS Off

Minimum Delay

Receive Timeout

Data Link Address

Common ASDU Address

 

104S Protocol Specification

Operating in the Server mode, the protocol driver accepts commands from one or more clients to read/write data stored in the module's internal registers.

The 104S module acts as an input/output module between the IEC 60870-5-104 Ethernet network and many of the other serial and network protocols, as well as several proprietary interfaces.

General specifications include:

 

  • User-definable module memory usage
  • Protocol implementation conforms to the IEC 60870-5-104 specification with fully configurable parameters
  • SNTP (Simple Network Time Protocol) timestamping for detailed logging of data transactions

 

The 104S module accepts commands from an attached master unit on the network and generates unsolicited messages. These last sets of messages are either spontaneous or cyclic. Data transferred to the host is derived from the module's internal database. The remote master device can control data in the database and hence the devices connected using the other protocol in the module using standard control messages supported in the protocol. The remote master device uses the fully-configured databases in the module to control outputs and monitor inputs.

IEC 60870-5-104 Server

Configurable Parameters

Override StartDT 
Clear queue on close
t1 timeout set value 
t2 timeout set value
t3 timeout set value
k (maximum queue)
w (latest ack threshold)
Time DB Offset 

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (with no condensation )

Dimensions

Standard:
 5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)
Extended:
 5.20 in H x 2.73 in W x 4.52 in D
(13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
Serial Port Activity
Serial Port Error Status

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

10Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Application Ports

Modbus Plus Connector
Two DB9 Female Standard Modbus Plus connectors

Serial Port Isolation

2500 V RMS port signal isolation per UL 1577
3000 VDC min. port to ground and port to logic power isolation

Shipped with Each Unit

Mini-DIN to DB-9M serial cables 
4 ft RS-232 configuration cable
2.5mm screwdriver
CD (docs and Configuration utility)
RS-422/485 DB-9 to Screw Terminal Adaptor (1 or 4, depending on ports)

Certifications

Ex Certificate (ATEX Directive) 114.27 kB Last Modified 11/11/2013
CB Safety 35.78 kB Last Modified 08/27/2012
CE Mark 92.31 kB Last Modified 02/22/2013
Russian GOST-R 7.07 MB Last Modified 02/22/2013
GOST-R Declaration of Conformity 6.68 MB Last Modified 02/22/2013
UL/cUL; Class 1, Div 2 1.08 MB Last Modified 07/02/2013
UL/cUL; Class 1, Div 2 (Canada) 1.10 MB Last Modified 07/02/2013