5507-PDPS-HART

PROFIBUS DP Slave to HART Multi-drop Gateway

5507-PDPS-HART

The ProLinx PROFIBUS DP Slave to HART Multi-drop Gateway creates a powerful connection between devices on a PROFIBUS DP network and HART field devices. This stand-alone DIN-rail mounted protocol gateway provides one PROFIBUS DP Slave configurable DB9F port and 4 configurable HART Multi-drop channels.

The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.

The HART protocol driver works as a Master on four (HART) or eight channels (HART2 – not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.

Features and Benefits

Applications

The PDPS-HART modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate HART Multi-drop devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the HART support, the module provides a very powerful interface to the more than two million HART devices which are in use in the industrial marketplace today. Applications for the module are found in most industries, especially the Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Applications

The PDPS-HART modules are the ideal solution for the many applications where PROFIBUS DP connectivity can be used to integrate HART Multi-drop devices into a system. The PROFIBUS DP Slave gateway is a powerful module designed with Slave support, enabling easy connection to PROFIBUS master devices. In combination with the HART support, the module provides a very powerful interface to the more than two million HART devices which
 are in use in the industrial marketplace today. Applications for the module are found in most industries, especially Manufacturing, Oil and Gas, Electrical Power and Food Processing.

Specifications

Internal Database

The ProLinx module contains an internal database that consists of areas for application data, status information, and configuration information.

The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.

Application Data Area

The data area is used to store and retrieve data by the protocol drivers and for data exchange between protocols. The database is used as a source for write commands to remote devices and holds data collected from the remote devices. Commands defined in the configuration file (stored in the configuration data area) control how the data is to be handled in the database.

Status Data Area

This area is used to store error codes, counters, and port status information for each port.

Configuration Data Area

This area contains module configuration information such as port configuration, network information, and command configuration. This configuration file is downloaded to, or uploaded from, this area.

Hardware

Specification

Description

Power Supply

24 VDC nominal
18 to 32 VDC allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade

Current Load

500 mA max @ 32 VDC max

Operating Temperature

-4° F to 122° F (-20° C to 50° C)

Storage Temperature

-40° F to 185° F (-40° C to 85° C)

Relative Humidity

5% to 95% (without condensation)

Dimensions

Standard:
5.20 in H x 2.07 in W x 4.52 in D (13.2 cm x 5.25 cm x 11.48 cm)

Extended:
 5.20 in H x 2.73 in W x 4.52 in D (13.2 cm x 6.934 cm x 11.48 cm)

LED Indicators

Power and Module Status
Application Status
HART Channel Activity (Green)

(Ethernet-equiped Gateways Only)
Ethernet Link
Ethernet Activity

Configuration Serial Port

DB-9M RS-232 only
No hardware handshaking

Ethernet Port (Ethernet modules only)

RJ45 Connector

Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991

Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

HART Interface

Four (4) HART Multi-drop channels

Screw terminals for each channel

24 VDC power supply
(third-party, not supplied with the gateway)

Must have sufficient current capacity to supply all loop-powered HART devices

Screw terminals for 24 VDC available on HART connector, supplied with the gateway, for loop-powered configurations

Shipped with Each Unit

Mini-DIN to DB-9M serial cables
4 ft RS-232 configuration cable
2.5 mm screwdriver
CD (docs and Configuration utility)
RS232-to-RS422/RS485 Screw Terminal Adapter(s) (Serial Gateways Only)
HART Terminal Block connector

Downloads

ProSoft Configuration Builder (PCB)
PDPS HART Datasheet 70.56 kB Last Modified 04/26/2010
PDPS Driver Manual 684.88 kB Last Modified 12/10/2009
HART Driver Manual 922.47 kB Last Modified 09/15/2017
ProLinx GSD File 398.03 kB Last Modified 05/11/2010

Protocols

PDPS Protocol Specification


The PROFIBUS DP Slave protocol driver supports the PROFIBUS V0 Slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.


Protocol Specifications

The PROFIBUS DP Slave driver gives access to the ProLinx unit's internal database via 244 bytes of Input data and 244 bytes of Output data (maximum 400 bytes total). These Input and Output data blocks are mapped by the user within the ProLinx module's data memory allowing the user maximum flexibility and data transfer with other protocols.

General Parameters

GSD File

PRLX05A5.GSD

Downloadable from ProSoft Technology web site

PROFIBUS Specifications

Communication parameters

Baud Rate: 9.6 kbps to 12 Mbps

Supported I/O length

244 bytes Input data

244 bytes Output data

400 bytes total

Supported PROFIBUS DP features

PROFIBUS V0 Slave using Siemens SPC3 chipset

Freeze Mode

Sync Mode

Auto Baud Setting

Configurable Parameters

PROFIBUS Node Address: 1 to 125

Data byte swapping

Action on loss of PROFIBUS connection

Comm Fail Timeout Multiplier

Status Data location in Internal Database


HART Protocol Specification


The HART protocol driver works as a Master on four (HART) or eight channels (HART2 not available on certain configurations) per interface card, depending on implementation. Each channel is individually configurable.


Protocol Specifications

The HART Master Protocol exists in 4 channel implementations with HART2 allowing 8 channels. This driver can be configured on an individual channel basis to operate as a HART Master Station and supports all the available HART commands including Universal, Common Practice and Device Specific Commands. Each HART channel is independently configured to interface with the internal database in the module.

The auto-poll mode allows the module to automatically collect data from each HART instrument on the channel and store the data in the module's database without the use of user commands. The module automatically generates HART commands 0, 3, 13, 14 and 15.

General Parameters

Communication parameters

Number of HART Preambles: 2 to 50

Enable Handheld: Y or N

Primary Master: Y or N

Configurable Parameters per Channel

Auto-Poll Enable, Short / Long Address Retries, Retries After Error

Poll Time After Error, Number of Commands, Slave List Error Pointer

HART Driver

Command List

Up to 100 fully configurable commands per channel

Polling of command list

User configurable polling of commands, including disabled, continuous, on change of data (write only) and dynamically user or automatic enabled.

HART® is a registered trademark of the HART Communication Foundation


Certifications

Ex Certificate (ATEX Directive) 84.06 kB Last Modified 05/22/2015
CB Safety 35.78 kB Last Modified 08/27/2012
CE Mark 92.28 kB Last Modified 02/28/2013
Russian GOST-R 7.07 MB Last Modified 02/22/2013
GOST-R Declaration of Conformity 6.68 MB Last Modified 02/22/2013
UL/cUL; Class 1, Div 2 1.08 MB Last Modified 07/02/2013
UL/cUL; Class 1, Div 2 (Canada) 1.10 MB Last Modified 07/02/2013